DL-6MC/iDL-6MC Large Capacity Refrigerated Centrifuge

Compact refrigerated floor standing centrifuge is specially designed for universal use in blood banks, clinic laboratories, serology investigations, molecular biology, serum separation, and pharmaceutical applications, where repeatability of reliability of speed time, temperature, acceleration, and deceleration are significant factors in obtaining perfect separations of the distinct blood fractions, Widely used in the field of blood station, pharmaceutical factory, biochemistry, biological products and so on. It’s the ideal instrument for blood separation, protein precipitation, and cell collection.

Features of Large Capacity Refrigerated Centrifuge

DL-6MC:

  1. With the self-diagnostic and protection system for imbalance, over-speed, over-temperature. Greatly ensured the safe of users and machine.
  2. Adopt microprocessor control, high efficiency frequency inverter motor, R404a environmentally friendly refrigerant compressor.
  3. Emergency door lid release system, in case of unexpected power off.
  4. Equipped with wheels, easy to short distance move.
  5. Both touch and button operation, high-light touch LCD display shows full parameters.
  6. 35 programs can be editable, storable and retrievable, users can set 9 programs for daily use.

iDL-6MC:

  1. With the self-diagnostic and protection system for imbalance, over-speed, over-temperature. Greatly ensured the safe of users and machine.
  2. Electric control for both closing and openning door lid, with backup power to avoid power off unexpected, Backup power automatically recharges when machine powered on.
  3. Adopt microprocessor control, high efficiency frequency inverter motor, R404a environmentally friendly refrigerant compressor.
  4. With large 7 Inches color panel show all parameters, and can operate with gloves. .
  5. With wheels easy to short distance move, and wheels can be fixed.
  6. Automatic Rotor Identification to avoid over-high speed running of rotor.
  7. With USB Cord , Data can be stored and download by connecting with PC. (Option function)
  8. 99 programs can be store, and can set 9 programs for daily use
  9. When use with swing rotor, the rotor cover can be open with door lid openning, no need to operate by manual.
  10. Three-Level password protection, avoid mis-operate.
DL-6MC-LCD Display
LCD Display
DL-6MC-2 Intelligent Type
Intelligent Type

Specifications of the Large Capacity Refrigerated Centrifuge

ModelDL-6MC/iDL-6MCMax Speed6000r/min
Max RCF6680xgMax Capacity6×1000ml
Speed Accuracy±10r/minTimer Range0-99h 59 min
Temperature Range-20~+40℃control&drivemicroprocessor control/direct drive
Acc/dec Rate0-9(Grade)Program Store35
Motor Power3.8KWRefrigerator Power2.2KW
Noise≤60dB(A)Power SupplyAC220V /380V 50-60Hz 35A
Weight(Without Rotor)260kgDimensions730×840×1200mm(L×W×H)
Refrigeration SystemBig Brand High-performance Compressor CFC-free Refrigeration System
RotorNo.1  AR 6*500ml (6000rpm 6680xg)
No.2  SR 6*1000ml Round Cup (4200rom 5600xg)
No.3  SR 6*1000ml Oval Cup (4000rom 5600xg)

Rotors:

Application of DL-6MC/iDL-6MC Centrifuge

application of DL-6MC Large Capacity Refrigerated Centrifuge
Blood Bank
application of DL-6MC Large Capacity Refrigerated Centrifuge
Bio-Technology
application of DL-6MC Large Capacity Refrigerated Centrifuge
Chemistry Lab
application of DL-6MC Large Capacity Refrigerated Centrifuge
Bio-Pharmaceutical

Other Floor Ultra Capacity Centrifuge