Floortype Refrigerated Centrifuge DL-5M/DL-6M iDL-5M/iDL-6M/

DL-5M/DL-6M is a model, which compact size with large capacity refrigerated function. Widely used in Hospital, Blood bank, Bio-Chemistry, Bio-pharmaceutical and Scientific research Company.

Features of Floortype Refrigerated Centrifuge

  1. Microprocessor control, maintenance free motor, full steel structure, more durable.
  2. LCD/Touch colored LCD display, can independent set parameters of Speed/RCF/Time/Acc/Dec etc.
  3. Lid open programmable, motorized,Lid dropping and imbalance protection.
  4. With Emergency lid release in case of unexpected power off, Can’t run when lid open, neither open the lid when rotor runs.
  5. 304 stainless chamber, and varieties Rotors for option, to meet the requirement of user.
  6. The operation program can be edited, stored and retrieved, users can store 9 or 99 programs.
  7.  Rotor automatically identification function to avoid over speed running.(iDL-5M/iDL-6M)
  8. Equipped with USB cord to connect with PC.(iDL-5M/iDL-6M)
  9. Full automatically electric control to both open and close door lid, no need to manual close door lid. (iDL-5M/iDL-6M)
  10. Backup Power for emergency door lid open. (iDL-5M/iDL-6M)
Floortype Refrigerated Centrifuge DL-5M/DL-6M
LCD Display
Floortype Low Speed Centrifuge iDD5-MC-2
Intelligent Type

Technical Parameters of DL-5M/DL-6M Refrigerated Centrifuge

ModelDL-6M (LCD)DL-5M
iDL-6M (Touch LCD)iDL-5M (Touch LCD)
Max Speed6000r/min±10rpm5500r/min±10rpm
Max RCF5600×g5220×g
Max Capacity6×500ml
Temp. Range-20℃~+40℃ ±1℃
Timer0~99min59s
Noise≤60dB(A)
MotorFrequency Converter motor
Power SupplyAC220V & 110V 50-60Hz 30A
Dimension780×650×800mm(L×W×H)
Weight150kg

Rotors

No.CapacityMax SpeedMax RCF
No.1 AR12×10/15ml6000 r/min5500 r/min5600xg5220xg
No.2 SR4×750ml4000r/min3780×g
No.3 SR4×500ml4000r/min3580×g
No.4 SR4×250ml4000 r/min3300xg
No.5 SR4×500ml Oval4000 r/min3940xg
No.6 SR6×500ml4000 r/min4390xg
No.7 SR108/148×7ml4000 r/min3440xg
No. 8 MPT2×2×96wells4000 r/min2300xg
No.9 SR8×50ml4000 r/min3020xg
32×10/15ml
72×5ml
No. 9 SR4/8×100ml4000 r/min3020xg

Note: Rotors can customize made

Accessories Display

Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge
Accessories  of loortype Refrigerated Centrifuge

Other Floor Ultra Capacity Centrifuge