Lab Blenders Stomacher

Lab Blenders Stomacher
Lab Blenders Stomacher, also known as flapping / flapping homogenizer, can make the process of extracting bacteria from solid samples very simple. Just add the sample and diluent to the aseptic sample bag (the maximum sample volume can be processed is 400ml), and then put the sample bag into the flapping homogenizer to complete the sample processing. The products are widely used in microbiological testing of food and drugs, animal tissues and biological samples.
Features of Lab Blenders Stomacher
- Visual observation of homogenization process with transparent glass window
- The homogenization time and times are flexible and adjustable
- Seal the liquid overflow prevention system and add disposable consumables without washing utensils
- 10 groups of parameters are saved to facilitate user call
- The sample processing capacity ranges from 3ml to 400ml, which can meet the needs of different customers
- Samples and machines are not in direct contact, bacteria are not damaged, and cross-infection is avoided
Specifications of Lab Blenders Stomacher
Lab Blenders Stomacher DW-04
• Tapping speed: 6~9 times/s (in steps of 0.1 times/s)
• UV disinfection: None
• Temperature control: None
• Parameter storage: None
Lab Blenders Stomacher DW-09
• Tapping speed: 3 ~ 12 times/s (in steps of 0.1 times/s)
• UV disinfection: None
• Temperature control: None
• Parameter storage: 10 groups
Lab Blenders Stomacher DW-11L
• Tapping speed: 3 ~ 12 times/s (in steps of 0.1 times/s)
• UV disinfection: Yes
• Temperature control: RT-50C Adjustable
• Parameter storage: 10 groups
3 Types of Homogenizers
Drawell Ultrasonic Cell Shredder is a multi-functional and multi-purpose instrument that uses the cavitation effect of ultrasonic waves to process experimental samples. It is suitable for samples with a volume of 0.5-600ml. It has the advantages of continuously adjustable ultrasonic time and power. It can break various animal and plant tissues, cells, and bacteria. It can also be used for emulsification, separation, dispersion, extraction, and acceleration of chemical reactions, etc.
The ultra-high pressure cell crusher is a fast, convenient, and pollution-free cell crushing experimental instrument. Different pressures can be selected for different experiments during the operation. The maximum pressure is up to 256MPa (37120PSi), which can meet the requirements of various types of cell crushing. The nano-homogenization/dispersion requirements of the sample can also achieve effective temperature control, so as to effectively obtain the required substances in the cells.
3. Sterile Slap Homogenizer (Lab blenders stomacher)
Lab blenders stomacher sterile homogenizer, also known as slap homogenizer, can make the process of extracting bacteria from solid samples very simple, just add the sample and diluent to the sterile sample bag (maximum The sample can be processed up to 400ml), and then put the sample bag into the flapping homogenizer to complete the sample processing.
Applications of Lab Blenders Stomacher
- It is widely used in the homogenization treatment of animal tissues, biological samples, food (such as pig stomach, meat, fish, vegetables, fruits, biscuits, etc.),
- Used for cosmetics, especially for the preparation of samples for microbial testing. The operation is simple, convenient and time-consuming.
- Suitable for the homogenization of tumor tissues (such as liver cancer, colon cancer, gastric cancer, breast cancer), which can not only obtain a large number of single cells (up to 2 × 105 within 2 minutes), but also can be adjusted to achieve soft tissue cells.
What are the Advantages of the Drawell’s Lab Blenders Stomacher?
- Ensuring microbial viability. The gentle tapping action does not heat the sample or cause severe shear, maximizing microbial viability and improving test accuracy.
- Avoiding cross-contamination. Samples are handled in disposable sterile tapping bags, and the instrument itself does not come into direct contact with the sample, effectively preventing cross-contamination and simplifying cleaning.
- Increasing recovery. Studies have shown that the tapping method generally produces higher and more consistent microbial recoveries compared to traditional stirring methods.
- Safe and easy operation. The closed system reduces aerosol generation, protecting operator safety.
How to Maintain a Laboratory Blender Stomacher?
- Daily Cleaning: Clean the blades, container, and instrument surfaces promptly after use.
- Regular Inspection: Check the blades for sharpness and curling, and the seals for proper elasticity.
- Prevent Overloading: Do not exceed the instrument’s maximum capacity to avoid motor damage from overloading.
- Professional Calibration: Have the instrument regularly calibrated and thoroughly maintained by a qualified professional according to the manufacturer’s recommendations.
Why Choose US?
- Rich categories.
- The products are market-oriented and exported to many countries in the world.
- Perfect sales system, efficient and fast after-sales service.
- On-time delivery rate reaches 100%.
- High-cost performance.









