Laboratory Ultrasonic Cleaner

Ultrasonic Cleaner

Laboratory Ultrasonic Cleaner

The Ultrasonic cleaner is an advanced cleaning device designed to remove contaminants from delicate instruments and components using high-frequency ultrasonic waves. It effectively cleans surfaces without causing damage, making it ideal for laboratory equipment, medical tools, jewelry, and electronic parts, featuring adjustable cleaning time, temperature control, and durable construction.

Application Areas of Laboratory Ultrasonic Cleaner

Drawell Ultrasonic cleaners are used to clean many different types of objects, including jewelry, scientific samples, lenses, and other optical parts, watches, dental and surgical instruments, tools, coins, fountain pens, golf clubs, fishing reels, window blinds, firearm components, car fuel injectors, musical instruments, gramophone records, industrial machine parts, and electronic equipment. They are used in many jewelry workshops, watchmakers’ establishments, electronic repair workshops, and scientific labs.

apllication of Ultrasonic Cleaner

How Does Laboratory Ultrasonic Cleaner Work

  1. Cavitation: Ultrasonic waves penetrate the liquid with compression force and sharp high frequency, generating strong impact force, thereby stripping dirt from the surface of the object being cleaned.
  2. Straight-through flow: Straight-through flow stirs the dirt on the surface of the object being cleaned, and the cleaning liquid on the surface also generates convection, which accelerates the dissolution rate and has a great transport effect on the dirt.
  3. Acceleration: For high-frequency ultrasonic cleaning machines, the liquid particles are mainly accelerated by the impact of the particles under the action of ultrasound to perform ultra-precision cleaning on the dirt.

Differences Among Lab Ultrasonic Cleaning Machine

DW25 12D 3

D Series

  • Digital display
  • Stainless steel
  • 1-600 minutes adjustable
DW 100DT 6

DT Series

  • LCD display
  • Stainless steel
  • 1-99 minutes adjustable
DW 800DTD 3

DTD Series

  • LED display
  • Stainless steel
  • 1-999 minutes adjustable
DW 800DTS 3

DTS Series

  • Digital display
  • Stainless steel
  • 1-999 minutes adjustable
  • Dual-frequency
DWL 10DT 1

DWL Series

  • LCD display
  • Stainless steel
  • 1-999 minutes adjustable
  • Constant Temperature
DW 500DTY 2

DTY Series

  • LCD display
  • Stainless steel
  • 1-999 minutes adjustable
  • Multi-frequency

Specifications of Laboratory Ultrasonic Cleaner

(1) D Series Ultrasonic Cleaning Machine

Features:

  1. Digital display and setting ultrasonic cleaning time;
  2. Display working countdown time;
  3. Timing range: 1-600 minutes adjustable;
  4. Equipped with a special stainless steel basket, reduce sound cover;
  5. The shell and cover are made of stainless steel;
  6. The equipment is controlled by a single-chip controller;
  7. The latest working parameters can be stored in memory after power-off.

Model

DW-80

DW-120D

DW-5200D

DW25-12D

 

 

 

Picture

1422026151846670338

1422026192225234945

1422026246646329346

1422026286559326210

Inner Tank (L/W/H ( mm))

155×140×100

240×140×100

300×240v150

500×300×150

Volume (L)

2

3

10

22.5

Frequency(KHz)

40

40

40

40

Power (W)

80

120

200

500

Adjustable

Time  (min)

1-120

1-600

1-600

1-600

Drainage

/

/

√

√

Net

Weight (Kg)

2.2

4.5

6.8

13

Packing

Size (mm)

240×230×300

325×230×300

450×325×375

640×395×375

(2) DT Series Ultrasonic Cleaning Machine

Features:

  1. Digital display and setting ultrasonic cleaning time;
  2. Display working countdown time;
  3. Display the actual temperature of the cleaning tank;
  4. Temperature setting range: Ambient temperature–80℃;
  5. Timing range: 1-99 minutes adjustable;
  6. Equipped with a special stainless steel basket, reduce sound cover;
  7. The shell and cover are made of stainless steel;
  8. The equipment is controlled by a single-chip controller;
  9. The latest working parameters can be stored in memory after power-off.

Model

DW-100DT

DW-5200DT

DW25-12DT

DW-1200DT

 

 

 

Picture

1422026554638266369

1422026554638266369

1422026554638266369

1422026554638266369

Inner Tank (L/W/H ( mm))

300×150×100

300x240x150

500x300x150

600x400x300

Volume (L)

4.5

10

22.5

70

Frequency(KHz)

40

40

40

28

Power (W)

100

240

720

1200

Heating power(W)

200

800

1000

4000

Adjustable

temperature(℃)

RT-80

RT-80

RT-80

RT-80

Adjustable

Time  (min)

1-99

1-99

1-99

1-99

Net Rack

Yes

Yes

Yes

Yes

Sound reduce  cover

Yes

Yes

Yes

Yes

Drainage

/

Yes

Yes

Yes

(3) DTD Series Ultrasonic Cleaning Machine

Features:

  1. Large-screen LCD display;
  2. Display the parameters setting menu;
  3. Adjustable power: 40%-100%;
  4. Digital setting ultrasonic cleaning time;
  5. Working time countdown display;
  6. Display the actual temperature of the cleaning tank;
  7. Temperature setting Range: room temperature–80℃;
  8. Timing Range: 1-999minutes adjustable;
  9. Equipped with a special stainless steel basket, reduce sound cover;
  10. The shell and cover are made of stainless steel;
  11. The equipment is controlled by a single-chip controller;
  12. The latest working parameters can be stored in memory after power-off.

Model

DW-3200DTD

DW-5200DTD

DW-4200DTD

DW25-12DTD

 

 

 

Picture

1422026865956286466

1422026865956286466

1422026865956286466

1422026865956286466

Inner Tank (L/W/H ( mm))

300x155x150

300x240x150

300x240x200

500x300x150

Volume (L)

6

10

14.4

22.5

Frequency(KHz)

40

40

40

28

Power (W)

180

240

480

600

Power Adjustable

(%)

40-100

40-100

40-100

40-100

Heating power(W)

300

500

500

800

Adjustable

temperature(℃)

RT-80

RT-80

RT-80

RT-80

Adjustable

Time  (min)

1-999

1-999

1-999

1-999

Net Rack

Yes

Yes

Yes

Yes

Sound reduce  cover

Yes

Yes

Yes

Yes

Drainage

/

Yes

Yes

Yes

(4) DTS Series of Dual-frequency Ultrasonic Cleaning Machine

Features:

  1. Interchangeable use of two kinds of frequencies: 25KHz, 40KHz;
  2. Digital display and setting ultrasonic cleaning time;
  3. Display woking countdown time;
  4. Display the actual temperature of the cleaning tank;
  5. Temperature setting range: Ambient temperature — 80℃;
  6. Timing range: 1-999minutes adjustable;
  7. Equipped with a special stainless steel basket, reduce sound cover;
  8. The shell and cover are made of stainless steel;
  9. The equipment is controlled by a single-chip controller;
  10. The latest working parameters can be stored in memory after power-off.

Model

DW-3200DTS

DW-5200DTS

DW-4200DTS

DW25-12DTS

 

 

 

Picture

1422027177064591361

1422027205481000961

1422027231426965505

1422027261290409985

Inner Tank (L/W/H ( mm))

300x155x150

300x240x150

300x240x200

500x300x150

Volume (L)

6

10

14.4

22.5

Frequency(KHz)

25/40

25/40

25/40

25/28

Power (W)

180

240

480

600

Power Adjustable

(%)

40-100

40-100

40-100

40-100

Heating power(W)

400

800

800

1000

Adjustable

temperature(℃)

RT-80

RT-80

RT-80

RT-80

Adjustable

Time  (min)

1-999

1-999

1-999

1-999

Net Rack

Yes

Yes

Yes

Yes

Sound reduce  cover

Yes

Yes

Yes

Yes

Drainage

/

Yes

Yes

Yes

(5) DTY Multi-frequency Ultrasonic Cleaning Machine (25KHz,33KHz,40KHz,59KHz)

Features:

  1. Background light LCD screen;
  2. Microcomputer memory setting parameters;
  3. The ultrasonic working time is set up independently: (0-99 minutes adjustable);
  4. Multi-frequency conversion: 25KHz, 28KHz, 40KHz, 59KHz;
  5. Display woking countdown time;
  6. Display the actual temperature of the cleaning tank;
  7. Temperature setting range: Ambient Temperature — 80℃;
  8. Timing range: 0-999 minutes adjustable;
  9. Equipped with a special stainless steel basket, reduction sound cover;
  10. The shell and cover are made of stainless steel;
  11. The equipment is controlled by the single-chip controller;
  12. With drainage function.

Model

DW-300DTY

DW-400DTY

DW-500DTY

DW-600DTY

 

 

 

Picture

1422027597421932545

1422027597421932545

1422027597421932545

1422027597421932545

Inner Tank (L/W/H ( mm))

300x240x150

300x240x200

500x300x150

500x300x200

Volume (L)

10

15

22.5

30

Frequency(KHz)

25KHz,33KHz,40KHz,

59KHz

25KHz,33KHz,40KHz,

59KHz

25KHz,33KHz,40KHz,

59KHz

25KHz,33KHz,40KHz,

59KHz

Power (W)

360

480

600

840

Heating power(W)

800

800

1000

3000

Adjustable

temperature(℃)

RT-80

RT-80

RT-80

RT-80

Adjustable

Time  (min)

1-999

1-999

1-999

1-999

Net Rack

Yes

Yes

Yes

Yes

Sound reduce  cover

Yes

Yes

Yes

Yes

Drainage

Yes

Yes

Yes

Yes

Laboratory Ultrasonic Cleaning Machine Display

Ultrasonic Cleaner
Ultrasonic Cleaner

Customer Feedback on Laboratory Ultrasonic Cleaning Machine

Ultrasonic Cleaning Machine

How to Operate a Laboratory Ultrasonic Cleaner?

1. Preparation

Check whether the equipment is intact and has no damage or leakage. Select appropriate cleaning agent according to the nature of the items to be cleaned Completely immerse the items to be cleaned in the cleaning solution.

2. Operation

Turn on machine, adjust the appropriate cleaning time and power. According to needs, adjust the temperature of the cleaning solution accelerate the cleaning effect

3. End and follow-up processing

Take out the cleaned items and rinse them with clean water to remove the remaining cleaning agent and dirt. Clean the cleaning tank and cleaning liquid for next use.

Composition of Laboratory Ultrasonic Cleaner

  • The ultrasonic cleaner is is mainly composed of ultrasonic cleaning tank and ultrasonic generator.‌
  • ‌The ultrasonic cleaning tank is made of strong, elastic and corrosion-resistant stainless steel.
  • ‌The ultrasonic generator generates high-frequency resonance, so that the solvent in the cleaning tank is affected by ultrasonic waves to clean the dirt.

Other Products Recommend