Multiple Vacuum Filtration System
The Multiple Vacuum Filtration System is designed for single or parallel vacuum filtration of laboratory liquid samples, especially for microbiological filtration workflows. It is available with 1, 3 or 6 filtration stations, and each station has an independent control valve for flexible operation. Glass and stainless-steel 300 mL filtration units are available to suit different laboratory requirements.
- Filtration Stations: 1 / 3 / 6
- Filtration Unit Capacity: 300 mL
- Filtration Unit Material: Glass / Stainless Steel
- Manifold Material: Stainless Steel
- Station Control: Independent Valve
- Collection Bottle: Glass

Features of Multiple Vacuum Filtration System
- Each station uses separate control valve for independent operation, easy to use and disinfect with a high efficiency.
- This system can filtrate three or six samples at the same time at low rate, with a high sensitivity.
- Sturdy won’t tip when full loaded due to the units with low center of gravity.
- Anodized aluminium handles at both ends are designed for positioning on bench top.
- All MVFseries vacuum filtration devices are made of stainless steel which is suitable for filtration, especially in the microbiological field.
Specification of Multiple Vacuum Filtration System
| Model | Description | Picture |
| MVF0101S | 1) Stainless Steel Manifold 2) One 300ml Stainless Steel Filtration Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
| MVF0101G | 1) Stainless Steel Manifold 2) One 300ml Glass Filtration Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
| MVF0103S | 1) Stainless Steel Manifold 2) Three 300ml Stainless Steel Filtratio Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
| MVF0103G | 1) Stainless Steel Manifold 2) Three 300ml Glass Filtration Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
| MVF0106S | 1) Stainless Steel Manifold 2) Six 300ml Stainless Steel Filtration Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
| MVF0106G | 1) Stainless Steel Manifold 2) Six 300ml Glass Filtration Units 3) One Glass Collect Bottle 4) Two pieces of hosepipe | ![]() |
Optional
| Model | Description | Picture |
| MVFSM01 | Stainless Steel Manifold, single | ![]() |
| MVFSM03 | Stainless Steel Manifold, For Three Units | ![]() |
| MVFSM06 | Stainless Steel Manifold, For Six Units | ![]() |
| MVFF300G | Glass Funnel, 300ml | ![]() |
| MVFF300S | Stainless Steel Funnel, 300ml | ![]() |
Applications of Multiple Vacuum Filtration System

Microbiological Filtration
Suitable for vacuum filtration workflows involving microbiological laboratory samples using compatible filtration media.

Parallel Laboratory Filtration
Supports simultaneous filtration of three or six compatible liquid samples where multiple samples need to be processed in one batch.

Routine Liquid Sample Filtration
Suitable for general laboratory vacuum filtration of compatible liquid samples and suspensions.
Multiple Vacuum Filtration System Display
About Vacuum Pump
- It can be in service under the condition of no working medium (no oil) and will not produce any pollution. Moreover, there is filtering material in the air exchange bin to guarantee the air clean.
- New technologies and materials are used in production. It is easy to move and can work smoothly, which can guarantee the ideal vacuum and high rate of air flowing.
- It adopts the operation containing no friction, producing no calories and having no friction exhausts. The diaphragm is made of Nitrile Rubber, which resists the corrosion and has long operating life.
- The self-cooling air draft system is designed in the body. This system can keep the machine continuously running for 24 hours.
- The pressure can be regulated by a value to meet various vacuum needs withincertain range.
- The axletrees are classical, which are imported abroad. They have the features of steady running, low noise and high operating efficiency.
Specifications of Vacuum Pump
| VP020 | ||||
| Speed of Evacuation environment (L/Min) | 12 | Working Temp of pump body (℃) | <55 | |
| Dimensions(L x W x H) (mm) | 245*120*160 | Noise Level (DB) | <60 | |
| Weight (Kg) | 4 | Vacuum | 250mbar | |
| Voltage rating | 220Vac , 50Hz | Inlet(mm) | Ø6 | |
| Motor power (w) | Single phase 75 | Outlet (mm) | Ø6 | |
| Pump head | 1 | Temperature of working (℃) | 7-40 | |
| Extreme pressure | ≥0.075Mpa | Positive pressure | ≥30Psi | |
| Function | Vacuum& Pressure | |||
| VP033A | ||||
| Speed of Evacuation environment (L/Min) | 20 | Working Temp of pump body (℃) | <55 | |
| Dimensions(L x W x H) (mm) | 275*130*210 | Noise Level (DB) | <60 | |
| Weight (Kg) | 7 | Vacuum | 200mbar | |
| Voltage rating | 220Vac , 50Hz | Inlet (mm) | Ø6 | |
| Motor power (w) | 160 | Outlet (mm) | silencer | |
| Pump head | 1 | Temperature of working (℃) | 7-40 | |
| Extreme pressure | ≥0.08Mpa | Function | Vacuum | |
| VP050A | ||||
| Speed of Evacuation Environment (L/Min) | 30 | Working Temp ofpump body (℃) | <55 | ![]() |
| Dimensions (L x W x H) (mm) | 230*180*265 | Noise Level (DB) | <60 | |
| Weight (Kg) | 7.5 | Vacuum | 200mbar | |
| Voltage rating | 220Vac , 50Hz | Inlet(mm) | Ø6 | |
| Motor power (w) | 160 | Outlet(mm) | Ø6 | |
| Pump head | 1 | Temperature of working (℃) | 7-40 | |
| Extreme pressure | ≥0.08Mpa | Diaphragm Values | NBR | |
| Positive pressure | ≥30Psi | Function | Vacuum&Pressure | |
| VP050B | ||||
| Speed of Evacuation environment (L/Min) | 30 | Working Temp of pump body (℃) | <55 | ![]() |
| Dimensions (L x W x H) (mm) | 350*130*220 | Noise Level (DB) | <60 | |
| Weight (Kg) | 10 | Vacuum | 50mbar | |
| Voltage rating | 220Vac , 50Hz | Inlet (mm) | Ø6 | |
| Motor power (w) | 160 | Outlet (mm) | Ø6 | |
| Pump head | 1 | Temperature of working (℃) | 7-40 | |
| Extreme pressure | ≥0.095Mpa | Function | Vacuum | |
| Positive pressure | ≥30Psi | Function | Vacuum&Pressure | |
| VP100A | ||||
| Speed of Evacuation environment (L/Min) | 60 | Working Temp ofpump body (℃) | <55 | ![]() |
| Dimensions(L x W x H) (mm) | 310*200*210 | Noise Level (DB) | <60 | |
| Weight (Kg) | 10 | Vacuum | 200mbar | |
| Voltage rating | 220Vac , 50Hz | Inlet (mm) | Ø6 | |
| Motor power (w) | 160 | Outlet (mm) | Ø6 | |
| Pump head | 2 | Temperature of working (℃) | 7-40 | |
| Extreme pressure | ≥0.08Mpa | Diaphragm Values | NBR | |
| Positive pressure | ≥30Psi | Function | Vacuum&Pressure | |
Application of Vacuum Pump
- Vacuum Filtration
- Vacuum Distillation
- Vacuum Drying
- On Rotary Evaporators
- To Extract and Transfer Gases
- Gel Drying
Order Process

Why Choose Us?
“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.
User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.
To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.
1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.