Floor Ultra Capacity Centrifuge 1

Floor Ultra Capacity Centrifuge

What is Floor Ultra Capacity Centrifuge?

Floor ultra capacity centrifuge is a kind of material separation equipment. According to temperature control, it can be divided into floor ultra capacity refrigerated centrifuge and floor ultra capacity normal temperature centrifuge. And according to speed, it can be divided into floor ultra capacity low speed centrifuge and floor ultra capacity high speed centrifuge. Floor ultra capacity centrifuge has a beautiful appearance, good stability, and large capacity, it can accurately control the working time and is widely used in blood banks, blood stations, biological pharmaceutical factories, biochemistry, biological pharmaceutical, and other product research units.

Features of Floor Ultra Capacity Centrifuge

  1. Beautiful appearance;
  2. Good stability;
  3. Large capacity;
  4. Low noise;
  5. Microprocessor control, simple operation;
  6. Multiple protection systems.
Floor Ultra Capacity Centrifuge

Floor Standing Blood Blank Centrifuge Application Case

Floor Standing Centrifuge Operation Procedures and Instructions

Touch Screen Panel

Touch Screen
1-Set temperature2-Real temperature3-Set up4-Set Speed
5-Real speed6-Deceration grade7- Acceration grade8-Status
9-Program memory10- Rotor No.11-Start key12-Stop Key
13-Real time14-Real time left15-Rotor Capacity16-Rotor max RCF
17-Rotor max speed18-Open door key 19-Close door key

LCD Panel

LCD
1 Accelerate Key2 Decleration Key3 Move up key4 Move down Key
5 Confirm Key6 Cancel Key7 Running indicate light 8 Stop  indicate Light
 9 Start Key10 Stop/Open Key 

Contact us for more instructions!

Key Advantages/Benefits of Drawell’s Floor Ultra Capacity Centrifuge

  1. Handles large sample volumes, up to several liters in a single run.
  2. Reduces processing time in high-throughput environments.
  3. Advanced interface with LCD or touch screen control for precise operation and programming.
  4. Robust safety features ensure stability during prolonged, high-speed use.

How to Maintain a Floor-standing Ultra Capacity Centrifuge?

  1. Maintenance of the centrifuge chamber: Clean the centrifugal chamber time, take out rotor and then scrubbed by cleanly cloth. Put the silica gel bag into chamber if the centrifuge will not be used for a long time to absorb humidity and avoid rust.
  2. Maintenance of the rotor : Rotor block can not bump. Do not damage the cone. Clean carefully rotor block and rotor cone with soft cloth before the rotor put in and coated with a little Vaseline or other grease medical.
  3. Maintenance of the control box and work surface: Control box and work surfaces must be kept clean. Rotor centrifuge tube and other tools of centrifuge may not be placed on the panel to prevent scratches. Control box and work surface can be only used with a soft cloth and mild detergent.
  4. Maintenance of drive shaft: The drive shaft must not be hit for conical surface/cone protection. Use soft cloth to clean the drive shaft and taper hole before rotor installation, and then smear some Vaseline or other lubrication grease.

Applications of Floor Ultra Capacity Centrifuge

Centrifuges can separate large quantities of material for further study of biochemistry. Floor ultra capacity centrifuge is widely used in radioimmunity, biochemistry, pharmaceutical, and other industries, especially in the separation and purification of blood products.

  1. Collecting cell;
  2. Separated plasma;
  3. Isolation of DNA and protein molecules from a repurified preparation;
  4. Isolation of viruses as well as large-scale E. coli;
  5. Isolate nucleoprotein particles.
Application of Floor Ultra Capacity Centrifuge

Why Choose Us?