
Floor Ultra Capacity Centrifuge
What is Floor Ultra Capacity Centrifuge?
Floor ultra capacity centrifuge is a kind of material separation equipment. According to temperature control, it can be divided into floor ultra capacity refrigerated centrifuge and floor ultra capacity normal temperature centrifuge. And according to speed, it can be divided into floor ultra capacity low speed centrifuge and floor ultra capacity high speed centrifuge. Floor ultra capacity centrifuge has a beautiful appearance, good stability, and large capacity, it can accurately control the working time and is widely used in blood banks, blood stations, biological pharmaceutical factories, biochemistry, biological pharmaceutical, and other product research units.
Features of Floor Ultra Capacity Centrifuge
- Beautiful appearance;
- Good stability;
- Large capacity;
- Low noise;
- Microprocessor control, simple operation;
- Multiple protection systems.

Floortype Refrigerated Centrifuge DL-5M/DL-6M iDL-5M/iDL-6M/
• Max RCF:5220 / 5600xg
• Max Capacity:6x500ml
• LCD/Touch Screen
Floortype Low Speed Centrifuge DD5-MC/DD6-MC iDD5-MC/iDD6-MC
• Max RCF: 5220 / 5600xg
• Max Capacity: 6x500ml
• LCD/Touch Screen
DL-6MC/iDL-6MC Large Capacity Refrigerated Centrifuge
• Max RCF: 6680xg
• Max Capacity: 6x1000ml
• LCD/Touch Screen
DL-7MC/iDL-7MC Large Capacity Refrigerated Centrifuge
• Max RCF: 11620xg
• Max Capacity: 6x1000ml
• LCD/Touch Screen
DL8M-12L/iDL8M-12L Large Capacity Refrigerated Centrifuge
• Max RCF: 15200xg
• Max Capacity: 6x24000ml
• LCD/Touch Screen
Floortype High Speed Refrigerated Centrifuge GL-10MC iGL-10MC
• Max RCF: 18300xg
• Max Capacity: 6x1000ml
• LCD/Touch Screen
GL-21/22MC iGL-21/22MC Floortype High Speed Refrigerated Centrifuge
• Max RCF: 52300 / 53000xg
• Max Capacity: 3000ml
• LCD/Touch Screen
Floortype High Speed Refrigerated Centrifuge GL-24MC iGL-24MC
• Max RCF: 63070xg
• Max Capacity: 6x500ml
• LCD/Touch Screen
Floortype Full Automatic Uncap Centrifuge DD4-TM/TDL-420/DL4-TM iDD4-TM/iTDL-420/iDL4-TM
• Max RCF: 5200xg
• Max Capacity: 12×10/15ml
• LCD/Touch Screen
Crude Oil Centrifuge DL-5Y
• Max RCF: 4390xg
• Max Capacity: 16x100ml
• Display: LCD
Floor Standing Blood Blank Centrifuge Application Case
Floor Standing Centrifuge Operation Procedures and Instructions
Touch Screen Panel

| 1-Set temperature | 2-Real temperature | 3-Set up | 4-Set Speed |
| 5-Real speed | 6-Deceration grade | 7- Acceration grade | 8-Status |
| 9-Program memory | 10- Rotor No. | 11-Start key | 12-Stop Key |
| 13-Real time | 14-Real time left | 15-Rotor Capacity | 16-Rotor max RCF |
| 17-Rotor max speed | 18-Open door key | 19-Close door key |
LCD Panel

| 1 Accelerate Key | 2 Decleration Key | 3 Move up key | 4 Move down Key |
| 5 Confirm Key | 6 Cancel Key | 7 Running indicate light | 8 Stop indicate Light |
| 9 Start Key | 10 Stop/Open Key |
Contact us for more instructions!
Key Advantages/Benefits of Drawell’s Floor Ultra Capacity Centrifuge
- Handles large sample volumes, up to several liters in a single run.
- Reduces processing time in high-throughput environments.
- Advanced interface with LCD or touch screen control for precise operation and programming.
- Robust safety features ensure stability during prolonged, high-speed use.
How to Maintain a Floor-standing Ultra Capacity Centrifuge?
- Maintenance of the centrifuge chamber: Clean the centrifugal chamber time, take out rotor and then scrubbed by cleanly cloth. Put the silica gel bag into chamber if the centrifuge will not be used for a long time to absorb humidity and avoid rust.
- Maintenance of the rotor : Rotor block can not bump. Do not damage the cone. Clean carefully rotor block and rotor cone with soft cloth before the rotor put in and coated with a little Vaseline or other grease medical.
- Maintenance of the control box and work surface: Control box and work surfaces must be kept clean. Rotor centrifuge tube and other tools of centrifuge may not be placed on the panel to prevent scratches. Control box and work surface can be only used with a soft cloth and mild detergent.
- Maintenance of drive shaft: The drive shaft must not be hit for conical surface/cone protection. Use soft cloth to clean the drive shaft and taper hole before rotor installation, and then smear some Vaseline or other lubrication grease.
Applications of Floor Ultra Capacity Centrifuge
Centrifuges can separate large quantities of material for further study of biochemistry. Floor ultra capacity centrifuge is widely used in radioimmunity, biochemistry, pharmaceutical, and other industries, especially in the separation and purification of blood products.
- Collecting cell;
- Separated plasma;
- Isolation of DNA and protein molecules from a repurified preparation;
- Isolation of viruses as well as large-scale E. coli;
- Isolate nucleoprotein particles.

Why Choose Us?
“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.
User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.
To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.
1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.






















