Vertical Autoclave

Vertical Autoclave
Vertical autoclave is an instrument that can kill or remove all microorganisms on the medium, including bacterial spores and non-pathogenic microorganisms. There are usually three methods moist heat disinfection, dry heat disinfection, and chemical disinfection.
This series is a high-pressure steam sterilizer, which uses saturated pressure steam to quickly and reliably sterilize and sterilize items. It is suitable for medical and health, scientific research, agricultural, and other units. It can sterilize medical equipment, glassware, solution culture medium, mushroom planting substrate, etc.
Drawell autoclaves including vertical autoclave, portable autoclave and table top autoclaves.
Features of Vertical Autoclave
- Good sterilization effect: the steam sterilizer can inactivate the microorganisms in the article in a short time, and the sterilization effect is good.
- Easy to operate: The steam sterilizer is easy to operate, just put the items into the sterilization chamber, and then set the sterilization time and temperature.
- Safe and reliable: The steam sterilizer has multiple safety protection measures, such as over-temperature protection, pressure protection, automatic drainage, etc., to ensure the safety and reliability of the operation process.
How to Choose Vertical Autoclave Model?
DW-GR Food Vertical Autoclave
• Capacity: 60,85L,110L
DW-GWA Series Horizontal Autoclave
• Capacity: 180L, 280L, 350L
DW-GF Series Vertical Autoclave
• Capacity: 29/54/88/120/150/175L
DW-FD Series Vertical Autoclave
• Capacity: 29L,50L,80L,100L
DW-GR Series Vertical Autoclave
• Capacity: 60,85L,110L
DW-GI Series Vertical Autoclave
• Capacity: 29L,54L,80L,100L
DW-HD Series Vertical Autoclave
• Capacity: 35/50L/75/100L
DW-LD Series Vertical Autoclave
• Capacity: 35/50L/75/100/120/150L
DW-B Vertical Autoclave
• Automatic Release When Over-Pressure
• Manually Leak Steam
• Capacity: 35L,50L,75L,100L ,120L,150L
DW-B Digital Vertical Autoclave
• Led Digital Display
• Automatically Leak Steam
• Capacity: 35L,50L,75L,100L ,120L,150L
DW-B Hand Wheel & Digital Vertical Autoclave
• Water Shortage And Over Heating Protection Automatically Leak Steam
• Tempered Glass Anti-Scald Protection
• Capacity: 35L,50L,75L,100L
Applications of Vertical Autoclave
Steam sterilizers are mainly used in medical and health, life sciences, food processing, and other fields, such as hospitals, laboratories, pharmaceutical manufacturers, food processing enterprises, etc. It can sterilize various items, such as medical devices, medicines, petri dishes, test tubes, syringes, infusion sets, food, etc.

Which Samples Cannot be Sterilized by Vertical Autoclave?
This instrument shall not be used for purposes other than sterilization, and melting the agar, and it shall also not be used for sterilizing the fammable, explosive and readily oxidizable products or strong acid, alkali and saline solutions to avoid explosion, and corruption of sterilizer chamber or pipelines.
Sterilization Reference Table for Various Items
| Sterilization | Insulation time (min) | Relative steam temperature (℃) | Relative steam pressure (MPa) |
| Rubber series | 15 | ~121 | 0.125~0.155 |
| Dressing series | 30-45 | 121~126 | 0.125~0.155 |
| Container Culture medium series | 15 | 121~126 | 0.125~0.155 |
| Instruments series | 10 | 126~134 | 0.125~0.155 |
| Solutions series | 20-40 | 121~126 | 0.125~0.155 |
| Culture medium series | 20 | 115~121 | 0.125~0.155 |
| Other | 5-15 | 126~134 | 0.155~0.21 |
Vertical Sterilizer Appearance & Operation Instructions
GI Series
GR Series
How Does A Vertical Autoclave Sterilize Materials?
Drawell’s vertical autoclave uses pressurized saturated steam to kill all forms of microbial life, including spores.
- Loading: Place instruments or materials into the inner chamber.
- Lid Sealing: The top lid is locked with clamps or a locking ring for safety.
- Air Removal: Displaces air using gravity displacement or pre-vacuum cycles.
- Sterilization Phase: Heats to 121℃ (15 psi) or 134℃ (30 psi) for a set duration.
- Exhaust & Drying: Steam is released; some models include drying cycles.
Common Problems and Solutions for Vertical Autoclaves
- Temperature Not Reached—Check the heating element and ensure the water level is adequate.
- Steam Leaks—Check the lid gasket and locking clips.
- Wet Loads—Avoid overloading and ensure the dry cycle is working properly.
- Pressure Drops During Cycle—This could be caused by a faulty or leaky valve.
How Does A Vertical Autoclave Differ From A Horizontal Or Benchtop Autoclave?
A vertical autoclave is a cylindrical, upright steam sterilizer with a lid that opens from the top. Instruments and materials are placed vertically within the sterilization chamber.
Compared to horizontal autoclaves, vertical autoclaves typically have a smaller footprint, making them ideal for laboratories, hospitals, and research institutions with limited floor space. They are particularly well-suited for sterilizing liquid culture media, glassware, culture media, and surgical instruments.
Customer Feedback on the Vertical Autoclave

Vertical Autoclave Pictures
B Series
GI Series
GR Series
Hand Wheel Digital
Order Process






































