RVDV-2H High-Temperature Digital Viscometer
The RVDV-2H High-Temperature Digital Viscometer is designed for viscosity measurement of materials that require heating before or during testing. Its integrated high-temperature furnace provides controlled heating for elevated-temperature viscosity measurement, while the DV-2 system also displays shear rate and shear stress for more detailed test-condition monitoring.
- Viscosity Range:50–10,000,000 mPa·s
- Temperature Control:Up to 300°C
- Stepless Speed Control:0.1–200 RPM
- Sample Volume:10–20 mL
- Accuracy in Use:±1% Full Scale
Features of RVDV-2H Digital Viscometer
- The main measurement is solid at room temperature and liquid after high temperature heating, such as asphalt, hot melt adhesive, polyethylene wax and so on.
- The measured data can be displayed directly on the LCD screen without secondary calculation. < VSoft Viscometer Data Collection,Analysis and Graphing Software > can also be selected to realize data acquisition and analysis and to compile the viscosity-temperature curve.
- High subdivision stepper motor, accurate and stable speed.
- LCD liquid crystal with blue backlight function can directly display the viscosity, speed, percentile torque, spindle number and the maximum viscosity and temperature of the selected spindle at the current speed. DV-2 series can also show shear rate and shear stress. Viscosity value shows continuous change, beyond the measurement range there is an alarm sound prompt.
- The measuring performance of the instrument has reached the level of the same type of products abroad through computer correction accuracy.
- High-temperature furnace uses embedded integral heating, uniform heating and small thermal inertia.

What Can the RVDV-2H High-Temperature Digital Viscometer Measure?




How to Operate High-Temperature Digital Viscometer?

1. Prepare the Sample
Place approximately 10–20 mL of sample into the high-temperature sample container.

2. Set the Test Temperature
Heat the sample to the required measurement temperature.

3. Select Spindle and Speed
Install a suitable spindle and set the rotational speed according to the expected viscosity.

4. Allow the Reading to Stabilize
Confirm that temperature and viscosity readings have stabilized before recording the result.

5. Record or Export Data
Read the result directly from the display or use optional VSoft software for data collection and viscosity–temperature analysis.
RVDV-1H vs RVDV-2H
| Parameter | RVDV-1H | RVDV-2H |
| Viscosity Range | 100–10,000,000 mPa·s | 50–10,000,000 mPa·s |
| Speed Range | 0.1–99.9 RPM | 0.1–200 RPM |
| Temperature Range | RT+10°C–300°C | RT+10°C–300°C |
| Spindles | 21 / 27 / 28 / 29 | 21 / 27 / 28 / 29 |
| Shear Rate / Stress | — | Available |
Choose RVDV-2H when you need a lower starting viscosity range, speeds up to 200 RPM, or shear rate/shear stress display.
Popular Digital Viscometer Comparison
| Key Parameter | Drawell RVDV-2 | Brookfield DV2Plus RV | Anton Paar ViscoQC 300 R |
| Viscosity Range | 40–40,000,000 mPa·s | 100–40,000,000 mPa·s | 1.3–40,000,000 mPa·s |
| Speed Range | 0.1–200 RPM, stepless | 0.1–200 RPM | 0.01–250 RPM |
| Accuracy | ±1% F.S. | ±1% of range | ±1% F.S. |
| Standard Spindles | 6 × R-Series | 6 × RV | R-Series system |
Drawell provides a practical alternative for laboratories that need wide viscosity coverage, flexible speed control and multiple model options for low-, medium-, high- and high-temperature viscosity testing.

FAQ
Specifications of RVDV-2H Digital Viscometer
| Measuring Range(mPa·s) | 50 ~ 10,000,000 |
| Rotating Speed (RPM) | 0.1 ~ 200(Stepless Gear) |
| Number of Spindles | Spindles (Code21、27、28、29) are equipped with the product |
| Accuracy | ±1% full scale range in use |
| Repeatability | ±0.5% full scale range in use |
| Sample capacity (m L) | 10~20 |
| Temperature control range(℃) | 10℃ above ambient~300℃ |
| Power | Power adapter(input:220V 50Hz) |
| LCD screen display | Viscometer:The LCD screen can display the viscosity, speed, torque spindle, temperature,shear rate, shear force and the maximum viscosity can be measured in the current spindle speed value. The temperature controller:Display setting temperature and actual measuring temperature。 |
Components of RVDV-2H Digital Viscometer
| Digital viscosity meter | 1 pce | Ascending and falling | 1 set |
| Frame and pipe | 1 set | Power adapter | 1 pce |
| Standard spindle | 1 set | Spanner | 1 pce |
| Seat and leveling feet | 1 set | RTD temperature probe | 1 pce |
| Temperature controller | 1 pce | Heating furnace | 1 pce |
| Insulation cover | 1 pce | Special tweezers | 1 pce |
| Position bracket | 1 pce | Connect cable | 1 pce |
| Power cord | 1 pce | Connection hook | 2 set |
Customer Feedback

M* H***

Germany

A* K***

Poland

S* P***

Indonesia

A* E***

Egypt

L* C***

Chile

R* A***

UAE

C* M***

Brazil

N* T***
Vietnam

J* V***

South Africa

D* R***

Mexico

E* Y***

Turkey

Why Choose Us?
Competitive Price-to-Performance
Get the core viscosity measurement functions you need without paying extra for premium-brand features that may not be required for routine testing.
Wide Measurement Range
Cover 5–80,000,000 mPa·s, from many fluid formulations to higher-viscosity coatings, resins and adhesives.
More Models for Different Samples
Choose from low-, medium-, high-viscosity and high-temperature models up to 300°C, instead of forcing one instrument to cover every application.
Free Warranty and After-Sales
We provide a 1-year free warranty and remote guidance to help you address and resolve any issues. Throughout the after-sales period, we remain available to offer free online technical support.















