RVDV-1H High-Temperature Digital Viscometer

The RVDV-1H High-Temperature Digital Viscometer is designed for viscosity measurement of materials that are solid or highly viscous at room temperature and become suitable for testing after heating. Its integrated high-temperature furnace provides controlled heating for viscosity measurement up to 300°C, while the LCD displays the main test conditions directly during operation.

  • Viscosity Range:100–10,000,000 mPa·s
  • Temperature Control:Up to 300°C
  • Stepless Speed Control:0.1–99.9 RPM
  • Sample Volume:10–20 mL
  • Accuracy in Use:±1% Full Scale

Features of RVDV-1H Digital Viscometer

  1. The main measurement is solid at room temperature and liquid after high temperature heating, such as asphalt, hot melt adhesive, polyethylene wax and so on.
  2. The measured data can be displayed directly on the LCD screen without secondary calculation. < VSoft Viscometer Data Collection,Analysis and Graphing Software > can also be selected to realize data acquisition and analysis and to compile the viscosity-temperature curve.
  3. High subdivision stepper motor, accurate and stable speed.
  4. LCD liquid crystal with blue backlight function can directly display the viscosity, speed, percentile torque, spindle number and the maximum viscosity and temperature of the selected spindle at the current speed. DV-2 series can also show shear rate and shear stress. Viscosity value shows continuous change, beyond the measurement range there is an alarm sound prompt.
  5. The measuring performance of the instrument has reached the level of the same type of products abroad through computer correction accuracy.
  6. High-temperature furnace uses embedded integral heating, uniform heating and small thermal inertia.
RVDV-1H Digital Viscometer (2)

What Can the RVDV-1H High-Temperature Digital Viscometer Measure?

Asphalt and Bitumen
Asphalt / Bitumen
Evaluate viscosity at handling, mixing or application temperature
Hot Melt Adhesive
Hot Melt Adhesives
Check melt viscosity for formulation and processing control
Polyethylene
Polyethylene Wax
Measure viscosity after melting and compare different formulations
High Temperature Melt Materials
High-Temperature Melt Materials
Study viscosity changes under controlled elevated temperatures

How to Operate High-Temperature Digital Viscometer?

Prepare the Sample

1. Prepare the Sample

Place approximately 10–20 mL of sample into the high-temperature sample container.

Set the Test Temperature

2. Set the Test Temperature

Heat the sample to the required measurement temperature.

Select Spindle and Speed

3. Select Spindle and Speed

Install a suitable spindle and set the rotational speed according to the expected viscosity.

Allow the Reading to Stabilize

4. Allow the Reading to Stabilize

Confirm that temperature and viscosity readings have stabilized before recording the result.

Record or Export Data

5. Record or Export Data

Read the result directly from the display or use optional VSoft software for data collection and viscosity–temperature analysis.

RVDV-1H vs RVDV-2H

ParameterRVDV-1HRVDV-2H
Viscosity Range100–10,000,000 mPa·s50–10,000,000 mPa·s
Speed Range0.1–99.9 RPM0.1–200 RPM
Temperature RangeRT+10°C–300°CRT+10°C–300°C
Spindles21 / 27 / 28 / 2921 / 27 / 28 / 29
Shear Rate / Stress—Available

Choose RVDV-2H when you need a lower starting viscosity range, speeds up to 200 RPM, or shear rate/shear stress display.

Popular Digital Viscometer Comparison 

Key ParameterDrawell RVDV-2Brookfield DV2Plus RVAnton Paar ViscoQC 300 R
Viscosity Range40–40,000,000 mPa·s100–40,000,000 mPa·s1.3–40,000,000 mPa·s
Speed Range0.1–200 RPM, stepless0.1–200 RPM0.01–250 RPM
Accuracy±1% F.S.±1% of range±1% F.S.
Standard Spindles6 × R-Series6 × RVR-Series system

Drawell provides a practical alternative for laboratories that need wide viscosity coverage, flexible speed control and multiple model options for low-, medium-, high- and high-temperature viscosity testing.

Choose by Viscosity Range and Test Temperature

FAQ

The RVDV-1H measures from 100 to 10,000,000 mPa·s.

The temperature-control range extends from 10°C above ambient up to 300°C.

The specified sample volume is 10–20 mL.

The standard configuration includes No.21, 27, 28 and 29 spindles.

Speed is continuously adjustable from 0.1 to 99.9 RPM.

No. According to the brochure, shear rate and shear stress display is a DV-2 series function.

Yes. Optional VSoft can be used for data collection, analysis and viscosity–temperature curve generation.

The brochure specifically lists asphalt, hot melt adhesive and polyethylene wax.

Specifications of RVDV-1H Digital Viscometer

Measuring Range(mPa·s)100 ~ 10,000,000
Rotating Speed (RPM)0.1 ~ 99.9(Stepless Gear)
Number of SpindlesSpindles (Code21、27、28、29) are equipped with the product
Accuracy±1% full scale range in use
Repeatability±0.5% full scale range in use
Sample capacity
(m L)
10~20
Temperature control range(℃)10℃ above ambient~300℃
PowerPower adapter(input:220V   50Hz)
LCD screen displayViscometer:The LCD screen can display the viscosity, speed, torque spindle, temperature and the maximum viscosity can be measured in the current spindle speed value.
The temperature controller:Display setting temperature and actual measuring temperature。

Components of RVDV-1H Digital Viscometer

Digital viscosity meter1 pceAscending and falling1 set
Frame and pipe1 setPower adapter1 pce
Standard spindle1 setSpanner1 pce
Seat and leveling feet1 setRTD temperature probe1 pce
Temperature controller1 pceHeating furnace1 pce
Insulation cover1 pceSpecial tweezers1 pce
Position bracket1 pceConnect cable1 pce
Power cord1 pceConnection hook2 set

Customer Feedback

customer reviews

Why Choose Us?

Competitive Price-to-Performance

Get the core viscosity measurement functions you need without paying extra for premium-brand features that may not be required for routine testing.

Wide Measurement Range

Cover 5–80,000,000 mPa·s, from many fluid formulations to higher-viscosity coatings, resins and adhesives.

More Models for Different Samples

Choose from low-, medium-, high-viscosity and high-temperature models up to 300°C, instead of forcing one instrument to cover every application.

Free Warranty and After-Sales

We provide a 1-year free warranty and remote guidance to help you address and resolve any issues. Throughout the after-sales period, we remain available to offer free online technical support.

Other High-Temperature Digital Viscometer