DW-GR Series Vertical Autoclave

DW-GR Series vertical autoclave is a configurable vertical steam autoclave for laboratories handling liquids, glassware, instruments, wrapped materials, agar media and laboratory waste. Designed for routine and higher-throughput laboratory sterilization, with 60 L, 85 L and 110 L capacities and DA, DF and DR configurations for different water-management and drying requirements.

  • 60 / 85 / 110 L Capacity
  • 105-138℃ Sterilization
  • 6-Level Exhaust Control
  • DW-GR-DA: Fully automatic with fast cooling fan
  • DW-GR-DF: DW-GR-DA+ automatic water feeding
  • DW-GR-DR: DW-GR-DF+fully automatic drying function
DW-GR Vertical Autoclave-3

Key Features of DW-GR Series Vertical Autoclave

  1. Programmable Cycle Control: The microcomputer controller manages the sterilization process automatically and allows users to save frequently used programs.
  2. 6-Level Exhaust Control: Six exhaust-speed levels allow the operator to adjust pressure release according to different loads, particularly liquids and temperature-sensitive containers.
  3. Fast Cooling Fan: A cooling fan is standard across the DW-GR Series to help shorten the post-sterilization cooling stage.
  4. Cold-Air Discharge Monitoring: The system monitors cold-air removal during heating to support suitable saturated-steam conditions before sterilization.
  5. 20 / 60 Stored Programs: DA models store up to 20 programs, while DF and DR configurations store up to 60 programs.
  6. Agar Melting & Warming: Provides 60–115°C melting and 45–79°C warming, useful for agar and laboratory media preparation.
  7. Scheduled Start: Programs can be scheduled up to 15 days in advance for planned laboratory workflows.
  8. Optional Steam Condenser: The optional condenser converts exhaust steam into water, helping reduce visible steam and moisture released into the laboratory.

Safety Features of DW-GR Series Vertical Autoclave

  1. Lid Interlock & Closing Check: Mechanical and electrical checks prevent the cycle from starting unless the lid is correctly closed and locked.
  2. Cooling Lock: The lid-opening temperature can be set separately for different programs, helping prevent opening while liquid or solid loads remain excessively hot.
  3. Low-Water & Dry-Heating Protection: Multiple monitoring methods detect insufficient chamber water and help protect the heating system against dry operation.
  4. Pressure & Temperature Protection: Mechanical and electronic monitoring continuously checks chamber conditions. Abnormal pressure or temperature can trigger heating shutdown, pressure release and alarm functions.
  5. Electrical & Fault Protection: The controller monitors operating status and reports fault information when abnormal conditions are detected. Electrical protection includes leakage, overcurrent and short-circuit protection.

What Can the DW-GR Sterilize?

Glassware Solid Instruments
Glassware & Solid Instruments
Laboratory glassware, stainless steel tools, containers and other heat-resistant solid materials.
Medical Surgical Instruments
Medical & Surgical Instruments
Reusable heat-resistant medical instruments such as stainless steel forceps, scissors, trays and other sterilizable clinical tools.
Lab Production Materials
Lab & Production Materials
Suitable for routine sterilization work in research laboratories, pharmaceutical facilities, food testing laboratories and other controlled laboratory environments.
Liquid Media
Liquid Media
Culture media, aqueous solutions, laboratory reagents and liquids in suitable heat-resistant containers.

Spare part option of DW-GR Series Vertical Autoclave

DW-GR Vertical Autoclave-4(1)

Display of DW-GR Series Vertical Autoclave

GR SERIES Autoclave
GR SERIES Autoclave display

FAQ

DA is the standard configuration with fast cooling and controlled exhaust. DF adds automatic water filling. DR additionally provides automatic drying.

Yes. The series includes dedicated liquid and liquid-with-warming programs, with adjustable cooling-lock settings for liquid loads.

If frequent water handling is part of the workflow, DF or DR is generally more convenient because they provide automatic water filling. Choose DR if post-cycle drying is also required.

Yes. An optional floating PT100 load sensor can be placed within the load for additional temperature monitoring.

Yes. DAS, DFS and DRS configurations add a 0.2 μm PTFE exhaust filter and PT100 monitoring of the filter housing.

USB data transfer is available as an option. Printing and digital pressure-recording configurations are also available.

Yes. The calibration interface can accommodate up to 15 sensors with the appropriate adapter, and optional IQ/OQ/PQ documentation is available.

Yes. SUS304 is standard, while SUS316L is available as an optional chamber material.

Specification Table of DW-GR Series Vertical Autoclave

ModelStandard DW-GR60DAStandard DW-GR85DAStandard DW-GR110DA
Auto water fill DW-GR60DFAuto water fill DW-GR85DFAuto water fill DW-GR110DF
Auto drying DW-GR60DRAuto drying DW-GR85DRAuto drying DW-GR110DR
DifferenceDW-GR-DA: Fully automatic with fast cooling fan              
DW-GR-DF: DW-GR-DA+ automatic water feeding 
DW-GR-DR: DW-GR-DF+fully automatic drying function
Capacity(L)6085110
Dimension(L*W*H)(mm)DA:644x660x980DA: 644x660x980DA:644x660x980
DF/DR:644x831x980DF/DR:644x831x980DF/DR: 644x831x1180
Chamber dimension (Dia*H)(mm)Φ390×505Φ390×700Φ390×895
Rated power(W)29004600(2900 as option)4600
SUS 304 Basket(Dia*H)(mm)(Note 1)(Φ370×190)x2(Φ370×280)x2(Φ370×250)x3
Power requirement220V±10% 16A 50HZ/60HZ220V±10% 32A 50HZ/60HZ220V±10% 32A 50HZ/60HZ
Temperature display accuracy0.1℃
Working environment5℃~40℃  relative humidity ≤85%
Chamber materialSUS304 stainless steel
Sterilization temp.range105℃~138℃
Sterilization time range1~6000 min
Melting temp. range60℃~115℃
Melting time1-6000 min
Warming temp45℃~79℃
Warming time1~9999 min
Drying(only for DR)Drying time:1~300 min Drying temp:80~160℃
Cooling lock OPEN temp.range40℃~99℃ for solid, waste, agar, self-defined 40℃~80℃(note 2)for liquid
Sterilization modeLiquid, Liquid with warming, solid, Wrapped instrument, Fabric, Rubber, Fast, Waste, Agar, Self-defined
Program number savedDA: 20 programs   DF/DR: 60 programs
Exhaust speed controlFully automatic internal discharging with 6 levels choice
Lid open wayFlip open(up and down)
Water tankDA:2 water tanks to collect steamDF:l water storage tank more than DADR:1 water tank to collect steam+1 water storage tank (note 3)
Appointment timer range(Auto start up appointment)0~15 days
Pressure gauge range0.1~0.5MPa
Pressure valve set pressure0.29 Mpa
Controller“Inspiration” smart microcomputer controller
Safety DeviceEight column evenly distributed “interlock device electric double inter bock lid closing checking dry scorch protection. age), cooling lock, anti-scald lid and bench corner, automatic troubleshooting
Biosafety functionOption for 0.2um biosafety filter(basic model+S)
  • Note 1:Baskets can also be customized
  • Note 2:Cooling lock OPEN temp. is related to local boiling point
  • Note3:Optional sewer drainage for DR while manufacturing

Customer Feedback

Why Choose Us?

One-Station Shopping

“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem.

Customer-centric Services

User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country.

Online Support

To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.

100% Quality Guarantee

1-year free warranty includes repairing damaged parts and replacing selected ones (shipping extra). 5% is charged to extend it before it expires.