Edi-Q Series Deionized Water System (Tap water inlet)

With LCD controlling system, 3 way water quality sensor, timing and quality dispensing, single stage RO system,1 pump and IonpureEDI module, Edi-Q series deionized water system is superior choice of deionized water for general grade experiments.

With tap water inlet, the largest capacity is 240 liters per day. It can produce single stage RO water and deionized water. The single stage RO water’s ion rejection rate is more than 96%, and deionized water is stable grade II pure water with resistivity>5MΩ.cm(25℃), TOC<30ppb, and the lowest running cost.

It completely meets the requirements of general chemical or biological experiments for pure water, and is up to the standard of ISO 3696(Type II), ASTM D1193 (Resistivity of type II and TOC), and the requirements for pure water of CLSI (NCCLS) clinical laboratory, GB/T6682, America, Europe, Japan’s pharmacopeia.

Edi series water purification system

Features and Advantages

  1. Integrating with Ionpure EDI technology and module.
  2. The largest capacity is 240 liters pure water per day.
  3. LCD (resolution: 240×128, dimension: 106×57mm) controlling system, intuitively display the system running state and various parameters.
  4. 3 way online water quality sensor, detect the quality of feed water, RO water, deionized water, or ultrapure water respectively. And warn once water quality’s standard exceeding.
  5. Cartridges replacing alarm function, based on time and water quality, show cartridges’ used and residual life.
  6. Multiple alarm function: no feed water, full water, water quality’s standard exceeding, and cartridge life ending.
  7. Auto self-flushing of RO membrane function, extend RO membrane’s life.
  8. Auto running data storing function through RS232/USB communication port to computer for 1 year at least (optional).
  9. System sanitizing procedure, achieve the disinfection of ultrapure water’s tube and valve.
  10. System circulation function, achieve ultrapure water’s circulation to keep top quality of ultrapure water.
  11. Level II password, protect all the parameters setting, and prohibit any unauthorized setting change.
  12. Water dispensing function- timing and quality (time range: 1-99min, water quality range: 0.1-18.2MΩ.cm).
  13. External water tanks is optional to meet different need and assure ample water-supply.
  14. Whole plastic shell with high-strength, avoid rusting and keep clean, to meet GLP standard.
  15. 3 door and easy-to-replacing cartridge design, convenient to maintain system and replace cartridges.
  16. Tube and adapter with NSF authorization and top quality, reduce TOC level and assure ultrapure water’s quality.
  17. Optimized pretreatment (including PP fiber, KDF and active carbon cartridge), effectively protect RO membrane.
  18. RO module with DOW’s membrane, ensure long life, stable operation and high desalinization rate.
  19. 4 in 1 ultrapure cartridge (can be divided to 4 independent cartridge) with DOW’s top polishing resin, ensure ultrapure water’s quality up to 18.2 MΩ.cm, with the lowest TOC level.
  20. Double wavelength (185&254nm) ultraviolet lamp module, restrain bacteria’s increase and reduce TOC.
  21. MWCO 5000D ultrafiltration module, effectively eliminate endotoxin, and suitable for precise cell cultivating and IVF.
  22. (0.45+0.1)µm double layer PES terminal disinfection filter, assure that terminal pure water is absolutely axenic.

Flow Schematic

Edi Q series deionized water system flow schematic

Specifications

ModelEdi-Q10Edi-Q10UT
Output(25℃)*10 liters/hour
Pure water outlet2: reverse osmosis water, deionized water
Edi water quality
Resistivity>5MΩ.cm
TOC*<30ppb
Silicone rejection rate>99.9%
BacteriaN/A<0.1cfu/ml
Particle(>0.1μm)N/A<1/ml
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:500×360×540mm / Weight: about 20Kg
Electrical requirementsAC110-240V, 50/60Hz
Power120W
Standard configurationMain body (Including 1 set of cartridge)+20 liters PE tank

Remarks:

*The value will be influenced by temperature and feed water’s quality.

Edi-Q series can be upgraded to touch screen system, just the same as Master to Master Touch.