Master Series Ultrapure Water System (Tap water inlet)

Master Series Water Purification System provides a complete solution for producing high-quality pure and ultrapure water in laboratories. With intelligent control, real-time water quality monitoring, automatic system management, and advanced multi-stage purification technology, it delivers ultrapure water up to 18.2 MΩ·cm with excellent stability, low TOC, and reliable performance for various laboratory applications.

Features and Advantages

  1. Up to 18.2 MΩ·cm Ultrapure Water: 4-in-1 cartridge with DOW polishing resin ensures high resistivity and low TOC.
  2. 185/254 nm Dual-Wavelength UV: Inhibits microbial growth and reduces TOC.
  3. MWCO 5,000 Da Ultrafiltration: Removes endotoxins for cell culture, IVF, and other sensitive applications.
  4. 0.45 + 0.10 μm PES Final Filter: Provides high-efficiency terminal filtration for sterile water dispensing.
  5. DOW RO Membrane and Multi-Stage Pretreatment: PP fiber, KDF, and activated carbon protect the membrane and support stable desalination.
  6. 5.0-Inch HD Touchscreen: 16:9 color interface enables intuitive control and real-time system monitoring.
  7. 3-Point Water Quality Monitoring: Monitors feed, RO, deionized, or ultrapure water with automatic out-of-range alarms.
  8. Dual Flow Sensors: Enable quantitative dispensing of RO, deionized, or ultrapure water.
  9. Automatic Circulation, Sanitization and RO Flushing: Maintains water quality, disinfects internal tubing and valves, and extends RO membrane life through programmable flushing.
  10. Intelligent Cartridge and Alarm Management: Displays cartridge usage and remaining life, with alarms for no feed water, full tank, abnormal water quality, and cartridge expiration.
  11. Automatic Data Recording: Built-in SD card stores operating data, with USB export for documentation and traceability.
  12. Comprehensive System Management: Displays operating status, water quality, cartridge usage, and alarm records, with 0–60-minute standby and 0–24-hour scheduled shutdown.
  13. Level II Password Protection: Prevents unauthorized changes to operating parameters.
  14. Flexible Tank Configuration: Supports liquid-level PE tanks, pressure tanks, and optional external tanks.
  15. GLP-Compatible, Easy-Maintenance Design: Corrosion-resistant housing, three-door cartridge access, and NSF-certified tubing and fittings simplify cleaning and maintenance.
master series-1

Applications

Scientific Research and Laboratories

Scientific Research and Laboratories

General Experiments: Reagent preparation, solvents for physicochemical analysis, and water for cleaning glassware used in universities and research institutes.
Precision Instruments: High-purity water for instruments such as HPLC, AAS, and ICP.

Industry and Electronics

Industry and Electronics

Microelectronics: Cleaning and ultrapure water preparation for integrated circuits, semiconductors, circuit boards, and cathode ray tubes, as well as surface cleaning and treatment.
Fine Chemicals: Raw materials used in the production of high-end daily chemical products, fine chemicals, and inks and coatings.

Pharmaceuticals and Medical Services

Pharmaceuticals and Medical Services

Pharmaceutical Water: Used for the production and preparation of large-volume parenteral solutions, injections, oral liquids, and other pharmaceutical products.
Medical Devices: Water supply for hospital central laboratories, hemodialysis centers, and the cleaning of medical equipment.

Food and Beverages

Food and Beverages

Beverage Purification: Water used in the production of bottled water, carbonated beverages, fruit juices, and beer.
Brewing and Processing: Blending of food additives and cleaning and disinfection of food processing equipment.

Accessories

Filter cartridge filter bottle


Filter cartridge + filter bottle

  • It intercepts silt and rust, adsorbs residual chlorine and organic matter, and protects the downstream RO membrane.(prevents scaling)
  • Removes 95-99% of ions
  • Removes bacteria, viruses, and organic matter

Ultrapure water circulating tank

The inner layer is made of low-leaching, surfactant-free, adhesive-free, and colorless filler HDPE; the top is equipped with a standard side-mounted air filter (adsorbing CO2 and organic matter); the water tank is equipped with a standard immersion 254nm germicidal UV lamp to control microbial growth and reduce TOC.

Ultrapure water circulating tank
RO membrane scaled

RO membrane

The main function of RO membranes is to remove salt, heavy metals, bacteria and colloids from water on a large scale, to preliminarily purify water sources and significantly reduce the consumption of downstream purification columns.

Ultrapurification Module

  • Removes organic matter
  • Increases to 18.2 MΩ·cm
  • Removes trace ions
Ultrapurification Module
Master seriesItem No.CommodityService life/ Replacement term
PC-M-PP5μmPP spun fiber cartridgeAbout 2-6 months
PC-M-KDFKinetic degradation fluxion cartridgeAbout 12 months
PC-M-AC-GGranular active carbon cartridgeAbout 6 months
RO-100GPD100GPD RO membraneAbout 12-24 months
RO-200GPD200GPD RO membraneAbout 12-24 months
PTC-AC-HZB1Post active carbon filterAbout 9000 liters pure water
PTC-MBR-MMixed bed resin cartridgeAbout 1000 liters pure water
PTC-MBR-M4 About 4000 liters pure water
PTC-UPPR-MUltrapure polishing resin cartridgeAbout 1000 liters pure water/ pc
PTC-UPPR-M4 About 4000 liters pure water
PTC-UPPR-MV About 1000 liters pure water
PTC-UPPR-M4V About 4000 liters pure water
TF-(0.45+0.1) um-S(0.45+0.1)μm terminal filter–
UF-5000DMWCO5000D UF cartridgeAbout 9000 hours
UV-(185nm&254nm)-10W-MDouble wavelength (185nm&254nm)UV cartridge–
LAMP-(185nm&254nm)-10W-MDouble wavelength (185&254nm) UV lampAbout 9000 hours
UV-254-10W-M254nm wavelength UV cartridge 
LAMP-254-10W-M254nm wavelength UV lampAbout 9000 hours

Master Series Ultrapure Water System Pictures

MASTER SERIES-A

Reviews of Drawell Master Series Ultrapure Water System

Master D series Water Purification System
Master S series

FAQ

Master S series: Direct tap water intake, built-in PP cotton, KDF, and activated carbon pre-treatment + Dow RO membrane, complete with a complete water purification process;

Master-D series: Can only be connected to pre-treated pure water/distilled water/deionized water, no RO reverse osmosis module, suitable for laboratories with existing pre-purified water systems.

The end-stage double-layer PES filtration can retain particles >0.1μm; high-end UVF/UF models are equipped with multi-stage purification columns to remove RNase and DNase, suitable for molecular biology experiments such as PCR and protein analysis.

The dual-outlet design simultaneously produces RO pure water + 18.2 MΩ・cm ultrapure water; the Master-D series has a maximum water production rate of 2L/min, and the Master series is available in S15 and S30 flow rate specifications, which can be selected according to needs.

Ultrapure water can stably reach 18.2 MΩ・cm at 25℃; deionized water resistivity ≥5 MΩ・cm. It fully complies with various top-level laboratory water standards such as ASTM, CAP, CLSI, EP, and USP, and is suitable for high-precision experiments such as cell culture, molecular experiments, and physicochemical analysis.

Master-D Inlet Water: RO pure water / distilled water / deionized water, temperature 5-45℃, standard 1 atmosphere; Master S series is compatible with municipal tap water, with multi-stage pre-filters protecting the RO membrane, offering a wider range of inlet water adaptability.

To prevent employees from accidentally modifying parameters. Equipped with a two-level access password, equipment parameter settings are locked, preventing unauthorized personnel from modifying operating parameters, complying with GLP laboratory management standards.

An external water tank is available as an option to meet the needs of large-volume continuous water intake scenarios, ensuring an ample water supply.

Equipped with a genuine Dow RO membrane, with a desalination rate >99%, stable operation, and a longer lifespan. Multi-stage pre-treatment filters significantly extend the membrane’s lifespan.

The four-stage integrated ultrapure column uses Dow’s high-end polishing resin to stably maintain a low TOC water quality of 18.2MΩ; the piping and adapters are all made of NSF-certified food-grade materials, eliminating secondary contamination and controlling TOC.

University research laboratories, pharmaceutical testing, third-party testing, hospital laboratories, biological cell laboratories, IVF reproductive centers, physicochemical chromatography analysis laboratories, etc.

Master-S series ultrapure water system (Tap water inlet)

  1. With LCD controlling system, 3 way water quality sensor, timing and quality dispensing, single stage RO system and 2 pumps.
  2. With tap water inlet, its output ranges from 15 to 30 liters/hour.
  3. It can produce single stage RO water and ultrapure water.
  4. The single stage RO water’s ion rejection rate is more than 96%, and the ultrapure water’s resistivity absolutely reaches to 18.2MΩ.cm.
  5. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.

Specifications

ModelStandardEliminating endotoxinLow TOCSynthesizing
Master-S15Master-S15UFMaster-S15UVMaster-S15UVF
Master-S30Master-S30UFMaster-S30UVMaster-S30UVF
Output(25℃)*15series-15 liters/hour, 30 series-30 liters/hour
Flow rateUp to 2 liters/minute (with pressure tank)
Pure water outlet2: reverse osmosis water, ultrapure water
Ultrapure water quality
Resistivity(25℃)18.2MΩ.cm
TOC*<10ppb<10ppb<3ppb<3ppb
Bacteria<0.1cfu/ml
Particle(>0.1μm)<1/ml
EndotoxinN/A<0.001Eu/mlN/A<0.001Eu/ml
RNasesN/A<0.01ng/mlN/A<0.01ng/ml
DNasesN/A<4pg/μlN/A<4pg/μl
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:500×360×540mm / Weight: about 20Kg
Electrical requirementsAC110-240V, 50/60Hz
Power120W
Standard configurationMain body (Including 1 set of cartridge)+15 liters pressure tank

Remarks: The value will be influenced by temperature and feed water’s quality.

Master-D series ultrapure water system (Distilled water inlet)

  1. With LCD controlling system, 3 way water quality sensor, timing and quality dispensing and 1 pump.
  2. With pure water or distilled water inlet, its output is up to 2 liters/minute.
  3. It can produce deionized water and ultrapure water.
  4. The deionized water’s resistivity is above 5MΩ.cm, and the ultrapure water’s resistivity absolutely reaches to 18.2MΩ.cm.
  5. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.

Specifications

ModelStandardEliminating endotoxinLow TOCSynthesizing
Master-DMaster-DUFMaster-DUVMaster-DUVF
OutputUp to 2 liters/minute (less output with UF cartridge)
Pure water outlet2: deionized water, ultrapure water
Ultrapure water quality
Resistivity(25℃)18.2MΩ.cm
TOC*<10ppb<10ppb<3ppb<3ppb
Bacteria<0.1cfu/ml
Particle(>0.1μm)<1/ml
EndotoxinN/A<0.001Eu/mlN/A<0.001Eu/ml
RNasesN/A<0.01ng/mlN/A<0.01ng/ml
DNasesN/A<4pg/μlN/A<4pg/μl
Deionized water quality
Resistivity(25℃)>5MΩ.cm
Feed water requirementsRO water, distilled water, deionized water, 5-45℃,1atm*
Dimension and weightLength×Width×Height:500×360×540mm / Weight: about 18Kg
Electrical requirementsAC110-240V, 50/60Hz
Power120W
Standard configurationMain body (Including 1 set of cartridge)

Remarks: The value will be influenced by temperature and feed water’s quality.

Master-Q series deionized water system (Tap water inlet)

With LCD controlling system, 3 way water quality sensor, timing and quality dispensing, single stage RO system and 1 pump, Master-Q series deionized water system is superior choice of deionized water for general grade experiments.

With tap water inlet, its output ranges from 15 to 30 liters/hour. It can produce single stage RO water and deionized water. The single stage RO water’s ion rejection rate is more than 96%, and the deionized water’s resistivity is more than 16MΩ.cm, near to18.2MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water.

Specifications

ModelMaster-Q15Master-Q15UTMaster-Q30Master-Q30UT
Output(25℃)*15 liters/hour30 liters/hour
Flow rateUp to 2 liters/minute (with pressure tank)
Pure water outlet2: reverse osmosis water, deionized water
Deionized water quality
Resistivity16-18.2MΩ.cm
BacteriaN/A<0.1cfu/mlN/A<0.1cfu/ml
Particle(>0.1μm)N/A<1/mlN/A<1/ml
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:500×360×540mm / Weight: about 20Kg
Electrical requirementsAC110-240V, 50/60Hz
Power120W
Standard configurationMain body (Including 1 set of cartridge)+15 liters pressure tank

Remarks: The value will be influenced by temperature and feed water’s quality.