TC2000-G1/G2/G3 Thermal Cycler Gradient

TC2000-G Series is a modular gradient thermal cycler platform available in single-, dual- and three-channel configurations. It is designed for laboratories that need to run one or several PCR programs at the same time while maintaining precise temperature control and flexible gradient settings. These three models differ in terms of channel configuration, module layout, and gradient span.

  • 96 Wells
  • 5°C/sec
  • 1 / 2 / 3 Channels
  • 30–105°C Gradient
  • 199 Cycles

Features of TC2000-G1/G2/G3

  1. Single / Dual / Triple Channel Design: Available as G1, G2 and G3 with 1×96, 2×48 or 3×32 modules while maintaining 96-well total capacity.
  2. Multiple PCR Programs at the Same Time: The multi-channel design allows different PCR gradient programs to run simultaneously across the available channels.
  3. 30–105°C Gradient PCR: Gradient temperature can be set from 30–105°C, with a gradient span of 1–42°C on G1 and 1–25°C on G2/G3.
  4. 5°C/sec Temperature Change: Peltier heating and cooling provides a maximum temperature change rate of 5°C/sec.
  5. Up to 30 Steps & 199 Cycles: Each program supports up to 30 steps and 199 cycles, with real-time progress and remaining-time display.
  6. 10.1″ Touch Screen + USB / Wi-Fi: The 10.1-inch 1280×800 touch display supports program operation, while USB and Wi-Fi provide data and connectivity options.

Applications of TC2000-G1/G2/G3

TC2000-G1/G2/G3 is an indispensable laboratory instrument in the field of molecular biology, which can be used for gene sequencing, gene cloning, gene expression, mutation, and plays an important role in various fields such as agriculture,food testing, environmental science, drug development and so on.

Applications of TC2000 G 3

Medical Research

For pathogen detection, e.g. gene identification of viruses, bacteria and fungi, mutation analysis of disease-associated genes, gene expression analysis in cancer research, etc.

Applications of TC2000 G 4

Biological Research

Genotyping, gene cloning, species identification, evolutionary analyses, and other studies

Applications of TC2000 G 5

Forensic Science

DNA analysis of crime scene samples to help identify suspects and provide a basis for public security case detection

Applications of TC2000 G

Agricultural sector

For genetic research on crops and livestock, e.g. breed improvement, genetic disease detection, etc.

Applications of TC2000 G 2

Food testing

Detection of pathogenic bacteria, genetically modified ingredients in food, etc.

Applications of TC2000 G 6

Environmental Science

Analysing microbial communities in the environment and detecting genetic effects of pollutants on organisms

Applications of TC2000 G 7

Drug Development

Screening of drug targets, assessment of drug effects on gene expression

Applications of TC2000 G 8

Genetic studies

Conducting diagnosis and research on human genetic diseases

Applications of TC2000 G 9

Palaeontology

Analyses species identification and classification, development and evolution, extinction event studies and the origin of species in ancient organisms

Product Display

FAQ

G1: 1 × 96 wells;  G2: 2 × 48 wells;  G3: 3 × 32 wells

G2 and G3 can run different PCR programs on separate modules at the same time.

All three models support a 30–105°C gradient temperature range.

G1: 1–42°C
G2/G3: 1–25°C
Set to 0 to turn off the gradient.

The maximum rate is 5°C/sec.

Control Accuracy: ±0.1°C
Uniformity at 55°C: ±0.2°C 

Each program supports up to 30 steps and 199 cycles.

Yes. The TC2000-G Series supports both Touchdown PCR and Long PCR.

The system can continue unfinished cycles automatically after power is restored.

Specifications of TC2000-G1/G2/G3

ModelTC2000-G1TC2000-G2TC2000-G3
Sample Capacity96×0.2mL PCR tube
12×PCR-8strips
1×0.2mL 96-well PCR plate
96×0.2mL PCR tube
12×PCR-8strips
96×0.2mL PCR tube
12×PCR-8strips
Module1×962×483×32
Sample module temperature control range [℃]0-105
Hot lid temperature control range [℃]30-115
Temperature display accuracy [℃]0.1
Temperature control accuracy [℃]±0.1
Temperature uniformity (at 55 ℃) [℃]±0.2
Maximum rate of temperature change5℃/Sec
Gradient Temp Setting Range [℃]30-105
Gradient span [℃]1-42℃, enter 0 to turn off the gradient1-25℃, enter 0 to turn off the gradient1-25℃, enter 0 to turn off the gradient
Temperature Control MethodBlock/Tube
Material of the carrier moduleAluminum
Display10.1 inches LCD 1280×800 
Input methodTouch panel
Power off protectYes
Skip to the next stepYes
Communication InterfaceUSB, WIFI
Number of program storage20000+ (USB FLASH)
User Defined File SystemUp to 30 steps and 199 cycles in a single program
Power Supply100-240V,50/60HZ,600W100-240V,50/60HZ,1000W100-240V,50/60HZ,1500W
Dimensions [W×D×H]310×422×264mm
Weight11kg
Permissible Ambient Temperature and Humidity5-40℃,80%RH

Why Choose Us?

  • One-Station Shopping

“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.

  • Customer-centric Services

User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.

  • Online Support

To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.

  • 100% Quality Guarantee Policy

1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.

Other PCR