Medium-1600 series Water Purification System

Medium-1600 series is nearly the smallest water system, with the same output-250 liters/hour. It meets the requirements of water for production and central water supply.

Models: Medium-1600RO, Medium-1600Q, Medium-1600S

Features and Advantages

Medium-1600Competitive product
The voltage is only DC24V, lower than human safe voltage(DC36V)The voltage is above of AC380V/220V, dangerous for operator
2 sets 800 GPD pure water system, independent operation. If one was broken, the other also runs.Only one system work. If going wrong, the machine could not work anymore.
Working pressure of RO membrane<70PSI (4.9kgf/cm2), assure safety.Working pressure of RO membrane >225PSI(15kgf/cm2), dangerous for operator
Floor space is only 0.5m2, save more room for laboratoryThe floor space is very large, waste the room of laboratory

Medium-1600RO Series Reverse Osmosis Water System

Medium-1600RO is single stage RO water system, with LCD controlling system, 2 way water quality sensor, timing and quality dispensing, stainless steel shell. The single stage RO water’s ion rejection rate is more than 96% (new RO membrane), organic rejection rate>99% (when mw>200 Dalton), particles and bacteria rejection rate>99%. It is suitable for glassware washing and general grade experiments.

Flow Schematic

Medium 1600 series Reverse Osmosis Water System FLOW

Specifications of Medium-1600RO Series Reverse Osmosis Water System

ModelMedium-1600RO
Output(25℃)*250 liters/hour
Pure water outlet1: reverse osmosis water
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Bacteria<0.1cfu/ml (with optional 0.2μm PES terminal filter)
Particle(>0.2μm)<1/ml (with optional 0.2μm PES terminal filter)
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:760×550×1210mm / Weight: about 80Kg
Electrical requirementsAC110-240V, 50/60Hz
Power480W
Standard configurationMain body (Including 1 set of cartridge)

Remarks:

*The value will be influenced by temperature and feed water’s quality.

Medium-1600Q series Deionized Water System

Medium-1600Q is deionized water system, with LCD controlling system, 2 way water quality sensor, timing and quality dispensing, stainless steel shell. The single stage RO water’s ion rejection rate is more than 96%, and the deionized water’s resistivity is more than 10MΩ.cm, near to18.2MΩ.cm. It completely meets the requirements of general chemical or biological experiments for pure water.

Flow Schematic

Medium 1600Q series Deionized Water System FLOW

Specifications of Medium-1600Q series Deionized Water System

ModelMedium-1600Q
Output(25℃)*250 liters/hour
Pure water outlet2: reverse osmosis water, deionized water
Deionized water quality
Resistivity10-18.2MΩ.cm
Bacteria<0.1cfu/ml (with optional 0.2μm PES terminal filter)
Particle(>0.2μm)<1/ml (with optional 0.2μm PES terminal filter)
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:760×550×1210mm / Weight: about 85Kg
Electrical requirementsAC110-240V, 50/60Hz
Power480W
Standard configurationMain body (Including 1 set of cartridge)

Remarks:

*The value will be infiuenced by temperature and feed water’s quality.

Medium-1600S series Ultrapure Water System

Medium-1600S is ultrapure water system, with LCD controlling system, 2 way water quality sensor, timing and quality dispensing, stainless steel shell. The single stage RO water’s ion rejection rate is more than 96%, and the ultrapure water’s resistivity absolutely reaches to 18.2MΩ.cm. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.

Flow Schematic

Medium 1600S series Ultrapure Water System

Specifications of Medium-1600S series Ultrapure Water System

ModelMedium-1600S
Output(25℃)*250 liters/hour
Pure water outlet2: reverse osmosis water, ultrapure water
Ultrapure water quality
Resistivity(25℃)18.2MΩ.cm
TOC*<10ppb
Bacteria<0.1cfu/ml (with optional 0.2μm PES terminal filter)
Particle(>0.2μm)<0.1cfu/ml (with optional 0.2μm PES terminal filter)
RO water quality
Ion rejection rate96%-99% (new RO membrane)
Organic rejection rate>99%, when MW>200 Dalton
Particles and bacteria rejection rate>99%
Feed water requirementsTap water, temperature:5-45℃,pressure:1.0-4.0Kgf/cm2
Dimension and weightLength×Width×Height:760×550×1210mm / Weight: about 88Kg
Electrical requirementsAC110-240V, 50/60Hz
Power480W
Standard configurationMain body (Including 1 set of cartridge)

Remarks:

*The value will be infiuenced by temperature and feed water’s quality.

Other Water Purification Systems