Kjeldahl Analyzer DW-K1160

DW-K1160 Automatic Kjeldahl Protein/Nitrogen Analyzer is unique in its intelligence, efficiency, energy saving and data sharing, bringing more new experiences to users. The product can be widely used in the fields of food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision and other fields of nitrogen or protein determination.

  • Fully automatic distillation and titration with optional 24-position autosampler.
  • FDA 21 CFR Part 11 and GMP compliant with audit trail and user management.
  • Burette resolution: 0.2–1 μL/step.
  • Up to 30% faster analysis and 50% lower water consumption.

Features

  1. Up to 24-position autosampler for high-throughput batch testing.
  2. Side-distillation and variable-speed titration reduce analysis time by approximately one-third.
  3. 10-inch HD touchscreen with Android OS for real-time process control and easy operation.
  4. Integrated titration module and real-time titration curves improve accuracy and method optimization.
  5. Real-time condensate temperature monitoring ensures complete condensation and reliable results.
  6. Separate cleaning and testing positions help prevent cross-contamination.
  7. Large-capacity reagent tank supports up to 500 analyses per filling.
  8. User-level management and data traceability support GMP and 21 CFR Part 11 requirements.
  9. Customizable reports can be exported as PDF or printed directly.
  10. Direct balance data transfer is available with specified balance models.
  11. Adjustable RGB color sensor supports AOAC, ISO, PA, and USP methods.
  12. The K1124 autosampler connects directly to the DW-K1160 without an additional power supply.
K1160-2

Applications of Kjeldahl Nitrogen Analyzer

Food and Agricultural Products Industry

Detects protein content in grains, dairy products, meat, beverages, and soy products, as well as specific indicators such as ammonium salts in soy sauce and sulfur dioxide in daylilies; assesses the freshness of aquatic products and meat products (volatile basic nitrogen).

Food and Agricultural Products Industry 1
Food and Agricultural Products Industry 21

Feed and Livestock Industry

Accurately determines the crude protein content in feed ingredients and finished products to ensure compliant nutritional ratios in animal husbandry.

Feed and Livestock Industry 1
Feed and Livestock Industry 2

Agriculture and Soil Science

Analyzes total nitrogen or ammonium nitrogen in soil, plants, and fertilizers to assess soil fertility and plant nutrient status.

Agriculture and Soil Science 1
Agriculture and Soil Science 2

Environmental Monitoring

Detects pollution indicators such as ammonia nitrogen and total Kjeldahl nitrogen in water bodies, sludge, and sediments.

Environmental Monitoring 1
Environmental Monitoring 21

Chemical and Pharmaceutical Industry

Determines the nitrogen content or specific components (such as caprolactam volatile bases) in samples of chemicals, pharmaceuticals, natural rubber, and ores.

Chemical and Pharmaceutical Industry 1
Chemical and Pharmaceutical Industry 2 1

FAQ

Automatic models are equipped with automatic pH/potential end-point recognition, no visual observation required. Setting tips: Use 0.1mol/L hydrochloric acid as titrant, and set the end-point pH between 4.6 and 5.0. For samples high in fat and protein, extend the pre-distillation time by 30 seconds appropriately to prevent ammonia volatilization and low test results.

① Incomplete digestion and carbonization caking of samples; ② Insufficient addition of lye leading to incomplete release of ammonia; ③ Water leakage of condenser tube and insufficient steam pressure; ④ Leakage of burette and invalid concentration of standard acid solution; ⑤ Poor sealing of digestion tube causing ammonia leakage.

Run the acid washing and pure water cleaning procedure after each test. For severe crystal blockages, circulate and flush with 5% dilute hydrochloric acid for 10 minutes, then rinse thoroughly with pure water. Drain the lye pipeline if the equipment will be idle for a long time to avoid pipeline blockage caused by ammonium sulfate and salt crystals.

High blank values are mostly caused by impurities in reagents, contaminated glassware or substandard water quality. Solutions: Choose superior pure sulfuric acid and boric acid; use ultrapure water throughout the experiment; pre-burn digestion tubes at high temperature to remove nitrogen-containing impurities; regularly replace fresh standard acid and sodium hydroxide solutions.

The standard cleaning includes three steps:

Flush the titration pipeline with dilute acid to neutralize residual alkaline liquid;

Rinse all distillation, condensation and titration pipelines with sufficient pure water;

Drain the lye delivery pipeline to prevent strong alkali from corroding pump tubes.

Specifications of Kjeldahl Analyzer DW-K1160

DW-K1160 Automatic Kjeldahl Nitrogen Protein Analyzer
Measuring range0.1mg ~240mg N
Analysis time3~8min/sample
RSD≤5%
Recovery≥99.5%
Burette volume0.2μL/step, 0.4μL/step and 1.0μL/step optional
Sample capacitysolid≤5g/sample, liquid≤20mL/sample
Water consumption in the distillation process0.5L/min
Data storage capacity1 million groups
InterfaceUSB, LAN, RS232, CAN, WIFI
Power supply220VAC±10%, 50Hz
Power2Kw
Net weight38Kg
Dimensions460mm×360mm×725mm
DW-K1124 Auto Sampler
Capacity24 samples per batch
Rotor speed≥0.04r/s
Sampling speed≥40mm/s
Tank capacity4×15L
InterfaceCAN
Voltage24V DC
Rated Power40W
Dimension(L×W×H)920mm×625mm×908mm
Weight80Kg
ItemK1100FK9860K9840
AutomaticYYN
Measuring range0.1mg~200mg N0.1mg~200mg N0.1mg~240mg N
ReproducibilityAverage value relative error±0.5%Average value relative error±0.5%Average value relative error±0.5%
Recovery≥99.5%≥99.5%≥99.5%
Sample capacitysolid 5g/sample, liquid 20mL/samplesolid 5g/sample, liquid 20mL/samplesolid 5g/sample, liquid 20mL/sample
Water consumption in the distillation process1.5L/min1.5L/min1.5L/min
Data storage1800 groups1000 groups—
Burette volume1.0μL/step2.0μL/step—
Analysis time3-8min/sample5~10min/sample—
Power supply220VAC±10%, 50/60Hz220VAC±10%, 50/60Hz220VAC±10%, 50/60Hz
Power2KW2KW1.3KW

FunctionK1100FK9860K9840
Steam Flow AdjustmentYYN
Steam modelYNN
Digestion tube dischargeYNN
Digestion tube cleaningYNN
Reagents bottle liquid level monitorYNN
Receiving cup cleaningYY–
Burette calibrationYY–
Data outputY (optional)NN
Method storageYYN
Boric acid pipeline cleaningYYN
Alkali pipeline cleaningYYY
Safety DoorYYY
Digestion tube on position monitorYNY
Condensing water flow monitorYYY
Water level monitorYYY
Steam generator temperature overload protectionYYY
Steam generator pressure overload protectionYNN
Liquid level monitor for Alkali/ acid/ Distilled water bottleYNN

Y: with this function.

N: without this function.

-: without this hardware configuration.

Model Selection and Configuration Recommendations

  1. If Need Kjeldahl Method with Digester, you can choose DW-SH220F  or  SH420F;
  2. Digestion process completed by DW-SH220F Kjeldahl Digester or SH420F Kjeldahl Digester;
  3. Heavy Metal Digestion can choose SH230N Heavy Metal Digester;

Why Choose Us?

One-Station Shopping

“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.

Customer-centric Services

User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.

Online Support

To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.

100% Quality Guarantee Policy

1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.

Customer Service of Kjeldahl Analyzer DW-K1160

DW K1160 Full Automatic Kjeldahl Analyzer
DW K1160 Full Automatic Kjeldahl Analyzer 2

Other Kjeldahl Nitrogen Analyzer