DW-RE Series Water Bath Rotary Evaporator
The DW-RE Series water bath rotary evaporators are designed for laboratory evaporation, concentration and reduced-pressure processing from small samples up to 5 L. The series combines LCD operation, stepless rotation, PID temperature control, automatic lifting and a three-layer vertical condenser, with standard and vacuum-control configurations available.
- 2 / 3 / 5 L Maximum Flask Range
- 25 / 25 / 43 mL/min Maximum Evaporation Capacity (H₂O)
- 0–310 rpm Rotation Speed
- RT–99°C ±0.5°C Water Bath
- 0–999 min Timer
- 150 mm Automatic Lifting Stroke
Features of DW-RE Series Water Bath Rotary Evaporator
- Large LCD display, menu interface and knob switch operation
- Rotating DC motor power: 70W Smooth start
- Heating pot: Teflon coating makes it easy to clean, resistant to corrosion, and resistant to high temperatures
- The condensing pipe is designed with drip point and anti-backflow device
- Unmanned mode safe operation function and automatic standby after the experiment
- Intermittent timing positive and negative rotation can be set, suitable for drying process
- Special bottle return knob design makes bottle return simple and convenient
- Optional vacuum system, can be set to control any vacuum degree
- Sealing unit: Imported PTFE+ special process mold synthesis
- The heating pot is designed with a safety handle and an insulated shell to prevent burns
- Touch type and handle type double automatic lifting and lifting make the lifting and lifting safer
- Equipped with a protection cap, which is heat preserved, energy saving and anti-spill and anti-boiling
Technical Parameter of DW-RE Series Water Bath Rotary Evaporator
| Model | DW-RE-2000A | DW-RE-3000A | DW-RE-5000A | |||
| Type | Standard | Vacuum control | Standard | Vacuum control | Standard | Vacuum control |
| Rotating Speed | LCD display 0~310rpm/min | LCD screen display 0~310rpm/min (Up to 310rpm/min when using a single rotating bottle within 3L) | ||||
| Evaporation capacity | Max.25ml/min(H2O) | Max.43ml/min(H2O) | ||||
| Vacuum | The internal vacuum of the equipment can reach 2mbar | |||||
| Vacuum control | / | Built-in vacuum controller (arbitrary control experiment required vacuum degree, setting range: (0~ -0.1Mpa) 0~1013mbar; Accuracy ±1). | / | Built-in vacuum controller (arbitrary control experiment required vacuum degree, setting range: (0~ -0.1Mpa) 0~1013mbar; Accuracy ±1). | / | Built-in vacuum controller (arbitrary control experiment required vacuum degree, setting range: (0~ -0.1Mpa) 0~1013mbar; Accuracy ±1). |
| Temperature range | water bath : room temperature ~99℃±0.5℃ | |||||
| Bath material | Disposable Teflon coating, easy to clean.Equipped with high temperature resistant Teflon protective cover. | |||||
| Bath size | φ23×13cm | 26×15cm | φ29*17cm | |||
| Sample bottle | Intermittent rotation around, intermittent time adjustable 0 ~ 60s, can be used for drying powder samples | |||||
| Rotating glass shaft | 29#/42 grinding integrated glass shaft with a . The evaporation bottle holder is attached to the bottle returner to prevent loss. | |||||
| Lift stroke | Touch + handle type double automatic balancing lifting (lifting stroke 150mm) The descending end point has a fixed 60mm safety distance to prevent collision. | |||||
| Temperature Control | Microcomputer PID controller, digital display. | |||||
| Temperature setting | Knob encoder, rotary input setting, large LCD screen display, convenient and fast | |||||
| Safety performance | Timing function (0~999min) : After the scheduled time, the device will automatically stop working and return to the standby state. When the equipment is abnormal and overtemperature warning, the main engine will be lifted automatically, and the instrument will lift the evaporation bottle automatically. | |||||
| Heater | Fully enclosed heater | |||||
| Power | 1.5KW | 1.5KW | 1.8KW | |||
| Scope | 25~2000mL | 25~3000mL | 25~5000mL | |||
| Sealing unit | Imported PTFE and special synthetic materials are processed and synthesized by special process technology to enhance sealing, corrosion resistance and wear resistance. | |||||
| Condensing pipe | Vertical, three-layer ball grinding mouth snake condensing pipe,condensing area of 0.18m², with dripping point and anti-backflow design. | Vertical, three-layer ball grinding mouth snake condensing pipe,condensing area of 0.21m², with dripping point and anti-backflow design. | Vertical, three-layer ball grinding mouth snake condensing pipe,condensing area of 0.31m², with dripping point and anti-backflow design. | |||
| Ambient temperature | 5~40℃ | |||||
| Voltage | AC220V/50HZ | |||||
| Instrument size | 660*420*830mm | 700*430*860mm | 740*440*960mm | |||
| Package size | 710*645*510mm | 710*645*790mm | 780*690*850mm | |||
| Gross weight | 30kg | 35kg | 42kg | |||
Applications of Rotary Evaporator

Chemical & Pharmaceutical Research
Used for concentrating reaction solutions, solvent extracts and pharmaceutical intermediates during laboratory synthesis and purification.

Natural Product Extraction
Suitable for concentrating plant extracts, herbal extracts and botanical fractions after solvent extraction.

Food & Flavor Research
Used for evaporation and concentration of food extracts, flavor solutions and plant-derived samples.

Environmental Sample Preparation
Supports solvent reduction and concentration of water extracts, soil extracts and environmental organic extracts before further analysis.

University & General Laboratory Research
Suitable for routine evaporation of research solutions, purified fractions and mixed laboratory samples.
DW-RE Series Water Bath Rotary Evaporator Pictures
How to Choose a Water Bath Rotary Evaporator Type?
Standard: For laboratories using an existing external vacuum-control setup.
Vacuum Control: Includes a built-in vacuum controller for setting and adjusting the required vacuum level during evaporation.