Desktop X-Ray Fluorescence Spectrometer (XRF)

Desktop X-Ray Fluorescence Spectrometer (XRF)
What is Desktop X-Ray Fluorescence Spectrometer (XRF)?
X-ray fluorescence (XRF) uses X-rays and fluorescence technology. When primary X-rays are irradiated on the sample to be tested, the secondary X-rays generated are called X-ray fluorescence. The composition and energy of the substance are analyzed by analyzing the wavelength and energy of the fluorescence.
The High-Performance Desktop XRF is equipped with globally advanced analysis technology, an intelligent vacuum system, and developed electronic technology. Combined with a low-energy tube vacuum system and low background technology. It efficiently reduces testing interference and improves energy resolution of Mg, Al, Si P, and other light elements in geology and minerals, and accordingly an ideal choice for quality control in large and middle-scaled enterprises.
Drawell provides you with two types of XRF – Handheld XRF and Desktop XRF.
Features of Desktop XRF
- High precision, fast testing speed, easy operation, etc.
- Bear several testing analysis modes, including alloy soil precious, and RoHS.
- Testing samples can be solids, liquids, and powders.
- Highly efficient super-thin window-ray light tube, which is specially developed for mineral testing, reaches the international advanced level.
- Automatic switch of collimator and filter according to different samples, eliminating the troublesome manual operation.
- Software protection: Automatic shut-down of software program when opening the cover during testing.
- Principle of Wavelength Dispersive Spectroscopy.

How to Choose The Right Desktop XRF for My Application?
Desktop XRF Mineral Analyzer (light elements) DW-EDX3600H
• Analytical Range: ppm to 99.99%
• Testing time: 60s-200s
• Resolution: (140±5)eV
DW-EDX6000C Energy-Dispersive XRF Spectrometer
• Analytical Limit: As low as 0.2 ppm
• Analytical Range: ppm to 99.99%
• 9 / 12 or 20 sample positions with spinning
DW-BP-9010A Wavelength Dispersion WD-XRF
• X ray tubes: 400W, Be window, Rh target(Pd optional)
Energy Dispersion X-ray Fluorescence Spectrometer (DW-NP-5010)
• Min. measuring limit: Cd/Hg/Br/Cr/Pb≤2 ppm
• Sample: Plastic/metal/film/powder/liquid etc.
DW-EDX6000C Energy-Dispersive XRF Spectrometer
• Analytical Limit: As low as 0.2 ppm
• Analytical Range: ppm to 99.99%
• 9 / 12 or 20 sample positions with spinning
Desktop XRF EDX2000A Automatic Micro-area Film Thickness Analyzer EDX Spectrometer
• Element Detection: 13AI~92U
• Simultaneous analysis of up to 24 elements and 5+ coatings
• Content test: 0.1%–99.99%
DW-BP-9010A Wavelength Dispersion WD-XRF
• X ray tubes: 400W, Be window, Rh target(Pd optional)
Energy Dispersion X-ray Fluorescence Spectrometer (DW-NP-5010)
• Min. measuring limit: Cd/Hg/Br/Cr/Pb≤2 ppm
• Sample: Plastic/metal/film/powder/liquid etc.
X-ray Fluorescence Spectrometer for Gold Analysis DW-EDX 800
• Sample: Solid
• Stability: 0.1% (Au≥95%)
Energy Dispersive X-Ray Fluorescence Spectrometer DW-EDX3000
• Analysis Range: 1ppm-99.99%
• Sample: powder, solid and liquid
• Measurement time: 60~300s
DW-EDX6000C Energy-Dispersive XRF Spectrometer
• Analytical Limit: As low as 0.2 ppm
• Analytical Range: ppm to 99.99%
• 9 / 12 or 20 sample positions with spinning
DW-EDX2800B RoHS Testing XRF Analyzer
• LOD: 1ppm
• Element Content: ppm to 99.99%
• Mining and alloy (Cu, stainless steel etc.) componential analysis
DW-EDX6000C Energy-Dispersive XRF Spectrometer
• Analytical Limit: As low as 0.2 ppm
• Analytical Range: ppm to 99.99%
• 9 / 12 or 20 sample positions with spinning
Wavelength Dispersive X-ray Fluorescence Spectrometer DW-WDX200
• Temp. accuracy: ±0.1℃
DW-EDX6000C Energy-Dispersive XRF Spectrometer
• Analytical Limit: As low as 0.2 ppm
• Analytical Range: ppm to 99.99%
• 9 / 12 or 20 sample positions with spinning
DW-BP-9010A Wavelength Dispersion WD-XRF
• X ray tubes: 400W, Be window, Rh target(Pd optional)
Why Choose Drawell’s Desktop XRF?
- Wide elemental detection range, covering everything from Na to U.
Whether it’s light elements like magnesium (Mg) and aluminum (Al) in cement, or heavy metals like lead (Pb) and cadmium (Cd) in alloys, this instrument addresses all elemental analysis needs in one go.

- Wide Dynamic Range: Simultaneous Detection from ppm to Percentage Content
Major elements and ppm-level trace elements in the sample do not need to be detected separately, eliminating the need for dilution and secondary sample preparation, significantly improving detection efficiency and making it suitable for the full analysis of complex sample compositions.

- High Resolution and Peak Separation Technology
Equipped with a high-resolution detector and advanced mathematical deconvolution algorithm, it can accurately separate overlapping peaks and spectral interference between elements, completely solving the problem of element misclassification and making the data more reliable.

- Intelligent Material Recognition and Automatic Test Curve Matching
After sample placement, the instrument quickly identifies the material type (alloy, ore, plastic, soil, etc.) and automatically matches the optimal calibration curve. Easy for beginners, eliminating the problem of invalid results due to incorrect curve selection.

- Multilingual Interface for Global Needs
Supports one-click switching between multiple languages including Chinese, English, French, Spanish, German, Italian, and Indonesian. All professional terminology is localized, ensuring seamless use by global teams.

- One-Click Report Generation and Automatic Layout
After testing, clicking “Generate Report” automatically exports a PDF/Excel file containing sample images, spectra, elemental content, and pass/fail criteria, conforming to ISO standards and ensuring worry-free auditing.

Desktop XRF vs Handheld XRF, Which One is Better?
| Parameter | Desktop XRF | Handheld XRF |
| Quantitative accuracy | ±0.01% (for precious metals) | ±0.1% |
| Repeatability | Excellent | Good |
| Trace element detection | ppm level | tens–hundreds ppm |
| Calibration flexibility | Advanced calibration | Limited calibration |
| Sample Size | Limited | Unlimited |
| Portability | Low | Very high |
| Best environment | Laboratory | Field |
| Typical analysis time | 5–60 s | 2–10 s |
| Primary use | Precise analysis | Rapid screening |
Applications of Desktop XRF

- Environmental protection: analysis of heavy metals in soil; analysis of harmful metals in paints, paints, pigments, and plastics
- Metal identification, scrap metal classification
- Petrochemical industry, catalyst, and additive element analysis
- QC/QA in metal production, casting, etc.
- Pharmaceutical Biomedicine
- Geological and mineral fields: mines, ore analysis, mineral analysis, beneficiation process control
- Material field: component analysis and quality control of refractory materials, glass, ceramics, cement, etc.
Different Applications of Spectrophotometer
| Application | Spectrophotometer Type | Picture | Model |
| Gold in Ore, Metallurgy. Geology, Mining, Petroleum. Cement, Soil, Medicine, etc. |
AAS | ![]() |
DW-AA320N |
| Alloy, Mineral, Precious Metal, RoHS, Catalyst etc. | XRF | ![]() |
DW-NP-5010 |
![]() |
EDX3600H | ||
![]() |
TrueX 900 | ||
![]() |
EDX800 | ||
| MaterialsAnalysis, Geology, Petrochemicals, Biology, Cement, Soil, Cosmetics, Food, etc. |
ICP-AES | ![]() |
ICP700T |
| Foundry, Steel, Metal Recovery, Smelting, MilitaryAerospace, etc. | Full Spectrum Direct Reading Spectrometer | ![]() |
DW-TY9000 |
How to Choose the Desktop XRF Model?
The user needs to provide the application field used, what is the sample to be tested, what elements need to be detected, what is the detection level, ppm or ppb, and so on. Then we will recommend the appropriate product model.
Order Process of Desktop XRF

Why Collaborate with Us?
“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.
User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.
To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.
1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.
Customer Feedback of XRF

































