Benchtop High Speed Refrigerated Centrifuge TGL-20/22M/MC/iTGL-20/22MC

TGL-20/22M/MC/iTGL-22MC is useful for routine application in biotechnology, PCR, life science and clinical labs, etc. This is suitable for routine sample analysis in Medical, Hospital, and Institutional laboratories. With a wide choice of rotor heads and adapters, this unit is truly versatile.

Features of Benchtop High Speed Refrigerated Centrifuge TGL-20/22M/MC/iTGL-22MC

  1. Reliable drive system:microprocessor control and Brand CFC-free compressor system
  2. Equipped with digital/Touch LCD screen, display all required parameters, easier to operate
  3. Emergency lid lock, in case of power off unexpected.
  4. Safety Interlock system that prevents opening the centrifuge lid during running.
  5. 10/99 programs can be stored, quickly recall the last used program.
  6. Rotor automatically identification function to avoid over speed running.(iTGL-20/22MC)
  7. Equipped with USB cord to connect with PC (.(iTGL-20/22MC))
  8. Electronic control for both door lid opening and closing. (.(iTGL-20/22MC))
Benchtop High Speed Refrigerated centrifuge TGL-18M/MC
Digital Display
TGL-sreies-LCD-白底
LCD Display
Touch screen
Touch screen

Technical Parameters of the TGL-20/22M/MC/iTGL-22MC Centrifuge

ModelTGL-20/22MTGL-20/22MCiTGL-20/22MCSpeed  Accuracy±10r/min
DisplayDigitalLCDTouch LCDTimer Range0~99h59min
Max Speed20500r/min    22000r/minTemp Range-20℃~﹢40℃
Max RCF29200xg   34700xgMax Capacity6×100ml
Noise≤60dB(A)Power AC220v&110V 50Hz
Weight65kgDimension540x625x380mm

Rotor of TGL-20/22M/MC/iTGL-22MC Centrifuge

TGL 16 rotor1No.1Max Speed:22000r/min
Capacity:12×1.5/2ml AR
Max RCF:34700xg
TGL 16 rotor2No.2Max Speed:16000r/min
Capacity:8/10/12×5ml AR
Max RCF:18200xg
TGL 16 rotor3No.3Max Speed:14000r/min
Capacity:12×10ml AR
Max RCF:23120xg
TGL 16 rotor4No.4Max Speed:15000r/min
Capacity:24×1.5/2ml AR
Max RCF:21800xg
TGL 16 rotor5No.5Max Speed:14000r/min
Capacity:48×1.5/2ml AR
Max RCF:17600xg
TGL 16 rotor6No.6Max Speed:14000r/min
Capacity:36×1.5/2ml AR
Max RCF:18200xg
TGL 16 rotor7No.7Max Speed:13000r/min
Capacity:6×50ml AR
Max RCF:16760xg
TGL 16 rotor8No.8  Max Speed:10000r/min
Capacity:4×100ml AR
Max RCF:10460xg
TGL 16 rotor No.9No.9Max Speed:10000r/min
Capacity:8×50ml AR
Max RCF:11980xg
TGL 16 rotor 10No.10Max Speed:10000r/min
Capacity:6×100ml AR
Max RCF:12200xg
TGL 16 rotor 11No.11Max Speed:13000r/min
Capacity:6×30ml AR
Max RCF:17000xg
TGL 16 rotor12No.12Max Speed:11000r/min
Capacity:12×15ml AR
Max RCF:14690xg

Note:Rotors can customize made

TGL-20/22M/MC/iTGL-22MC Centrifuge Display

Other Benchtop Refrigerated Centrifuge