iTGD-16MC iTGD-18MC iTGD-20MC Intelligent High & Low Speed Refrigerated Centrifuge

iTGD-16/18/20MC intelligent high & low speed refrigerated centrifuge is available with a wide range of rotors, and exceptional versatility. It has fast speed up and speeds down functions and LCD touch display. iTGD series centrifuge widely use in laboratory, medical, biological, research, molecular biology etc.

Features of Refrigerated Centrifuge iTGD-16/18/20MC

  1. Microprocessor control, speed control by frequency-conversion and CFC compressor.Maintenance free Frequency-conversion motor without carbon dust pollution.
  2. Advanced door lid control system can both electric control open and close door lid, also equipped with emergency lid lock release to avoid power off unexpected.
  3. 10 programs can be stored, quickly recall the last used program.
  4. Automatic rotor identification to avoid over speed running by mistake operate.
  5. Easy operation, 7 inches LCD touch panel, shows all parameters in screen.
  6. With Emergency lid lock release, in case of power off.
  7. Error minder for wrong operate or problem.

Technical Parameters of Refrigerated Centrifuge iTGD-16/18/20MC

ModeliTGD-16MCiTGD-18MCiTGD-20MCSpeed  Accuracy±10r/min
Max Speed16500r/min18500r/min20500r/minTimer Range1s~99h59mins 59s
Max RCF21800xg23500xg28200xgTemp Range-20℃~﹢40℃
DisplayLCD Touch displayMax Capacity4×250ml
Noise≤60dB(A)Power SupplyAC220v&110V 50Hz 10A
Weight85kgDimension720x500x420mm

Rotors of Refrigerated Centrifuge iTGD-16/18/20MC

No.1 AR TGD No.1 AR Max Speed:20500r/min No.2 AR TGD No.2 AR Max Speed:16000r/min
Capacity:12×1.5/2ml Capacity:8×5ml
Max RCF:28200xg Max RCF:3020xg
No.3 AR TGD No.3 AR Max Speed:14000r/min No.4 AR TGD No.4 AR Max Speed:15000r/min
Capacity:12×10ml Capacity:24×1.5/2ml
Max RCF:23120xg Max RCF:21800xg
No.5 SR TGD No.5 SR Max Speed:14000r/min No.6 AR TGD No.6 AR Max Speed:14000r/min
Capacity:48×1.5ml Capacity:36×1.5/2ml
Max RCF:17600xg Max RCF:18200xg
No.7 AR TGD No.7 AR Max Speed:13000r/min No.8 AR TGD No.8 AR Max Speed:10000r/min
Capacity:6×50ml Capacity:4×100ml
Max RCF:16760xg Max RCF:9800xg
No.9 SR TGD No.9 SR Max Speed:4000r/min No.10 AR TGD No.10 AR Max Speed:8000r/min
Capacity:4×250ml Capacity:6x100ml
Max RCF:3300xg Max RCF:9800xg
No.11 AR TGD No.11 AR Max Speed:13000r/min No.12 AR TGD No.12 AR Max Speed:12000r/min
Capacity:6x30ml Capacity:12x15ml
Max RCF:17000xg Max RCF:15100xg

iTGD-16/18/20MC Refrigerated Centrifuge Display

Other Benchtop Refrigerated Centrifuge