What is AES-8000 AC/DC Arc Emission Spectrometer?

AES-8000 AC-DC Arc Emission Spectrometer adopts high-sensitivity CMOS as the detector, and realizes full-spectrum acquisition within the band range. It can be widely used in geology, non-ferrous metals, and chemical industries. It can directly analyze powder samples without sample dissolution, which is an ideal instrument solution for qualitative and quantitative analysis of trace and trace elements in insoluble powder samples.

Features of AES-8000 AC/DC Arc Emission Spectrometer

  1. Efficient Optical Imaging System

Ebert-Fastic optical system and three-lens optical path are adopted to effectively remove stray light, eliminate halo and chromatic aberration, reduce background, enhance light gathering ability, good resolution, uniform spectral line quality, and fully inherit the optical path of a one-meter grating spectrograph The advantages.

  • Compact optical structure and high sensitivity;
  • Good image quality, straight focal plane;
  • Inverted line dispersion rate 0.64nm/mm;
  • The theoretical spectral resolution is 0.003nm (300nm).
AES-8000-6
  1. High-performance linear array CMOS sensor and high-speed acquisition system
  • Using UV-sensitive CMOS sensor, high sensitivity, wide dynamic range, small temperature drift; no need for coating, no device spectrum broadening effect, no film aging problem.
  • The high-speed multi-CMOS synchronous acquisition and data processing system based on FPGA technology not only completes the automatic measurement of analytical element spectral lines, but also realizes the functions of automatic calibration of synchronous spectral lines and automatic background subtraction.
  1. AC and DC arc excitation light source

It is convenient to switch between AC and DC arcs. According to different samples to be tested, selecting the appropriate excitation mode is beneficial to improve the analysis and test results. For non-conductive samples, select AC mode, and for conductive samples, select DC mode.

  1. Electrode Automatic Alignment

The upper and lower electrodes automatically move to the designated position according to the software parameter settings, and after the excitation is completed, remove, and replace the electrodes, which is easy to operate and has high alignment accuracy

DC Arc Emission Spectrometer
  1. Convenient viewing window

The patented electrode imaging projection technology displays all the excitation process on the observation window in front of the instrument, which is convenient for users to observe the excitation of the sample in the excitation chamber, and helps to understand the properties and excitation behavior of the sample.

  1. Powerful Analysis Software
  • Real-time automatic calibration of spectral lines to eliminate the influence of instrument drift;
  • Background is automatically deducted to reduce the interference of human factors;
  • Through the spectral line separation algorithm, reduce the influence of spectral interference;
  • Automatic switching of multi-spectrum determination to broaden the range of detection content;
  • The combination of two fitting methods improves the accuracy of sample analysis;
  • Abundant spectral line information, broadening the application field of analysis;
  • Special analysis software, suitable for different sample testing requirements.
  • Convenient data post-processing function shortens the experimental process and makes data processing more flexible;
AES-8000 AC DC Arc Emission Spectrometer
  1. Safety protection
  • The cooling circulating water flow monitoring of the electrode clip can avoid the high temperature burning of the electrode clip;
  • Activate the safety interlocking of the chamber door to protect the safety of operators.

Applications of AES-8000 AC/DC Arc Emission Spectrometer

  1. Simultaneous determination of Ag, Sn, B, Mo, Pb, Zn, Ni, Cu and other elements in geological samples; it can also be used for the detection of trace precious metal elements in geological samples (after separation and enrichment);
  2. Determination of several to dozens of impurity elements in high-purity metals and high-purity oxides, powder samples such as tungsten, molybdenum, cobalt, nickel, tellurium, bismuth, indium, tantalum, niobium, etc.;
  3. Analysis of trace and trace elements in insoluble powder samples such as ceramics, glass, coal ash, etc.
AES-8000 AC DC Arc Emission Spectrometer application

One of the indispensable supporting analysis programs for geochemical exploration samples.

AES-8000 AC DC Arc Emission Spectrometer application2

Ideal for detection of impurity components in high-purity substances.

Specifications of AES-8000 AC/DC Arc Emission Spectrometer

Optical path formVertically symmetrical Ebert-Fastic type
Plane Grating Lines2400 pieces/mm
Optical path focal length600mm
Theoretical spectrum0.003nm (300nm)
Resolution0.64nm/mm (first class)
Falling Line Dispersion RatioSynchronous high-speed acquisition system based on FPGA technology for high-performance CMOS sensor
Current range2~20A(AC) 2~15A(DC)
Excitation light sourceAC/DC arc
WeightAbout 180Kg
Dimensions (mm)1500(L)×820(W)×650(H)
Constant temperature of spectroscopic chamber35°C±0.1°C
Environmental conditionsRoom temperature 15°C~30°C Relative humidity<80%

Why Choose Us?

Order Process

order process of Automatic melting point meter

FAQ

– We are a factory.

  • Usually, MOQ is 1 piece.
  • The general MOQ differs greatly between different products if there is no stock. But the quantity still can be negotiated.

– Sample is available, but we do not provide free samples.

– OEM service is available with customer’s brand.

– We accept the payment by L/C, T/T, Paypal, Western Union, etc.

– Generally, it will take 7-15 working days after receiving your advance payment. Depend on the quantity.