Veterinary Patient Monitor

Veterinary Patient Monitor

What is Veterinary Patient Monitor?

Veterinary patient monitor is also called medical monitor, physiological monitor, or a display, which is an electronic medical device. This instrument can measure the patient’s vital signs, display the data obtained therefrom, and transmit it to the monitoring network.

In medicine, monitoring is the observation of a disease, condition, or one or several medical parameters over time.

It can be performed by continuously measuring certain parameters by using a medical monitor (for example, by continuously measuring vital signs by a bedside monitor), and/or by repeatedly performing medical tests.

Features of Veterinary Patient Monitor

  1. Several types of display are optional. 3.5’Large size color touch screen(optional),320X480pixels, 12.1-inch large-sized screen with high-tech white and black color, High-resolution LCD display, and 7” high-resolution color LCD display with adjustable brightness.
  2. Built-in rechargeable lithium battery for long-term continuous operation.
  3. Variety of NIBP Cuffs for different size animals.
  4. Expanded heart rate values and Veterinary specific Sp02 sensors to accommodate a variety of species.
  5. Three measurement modes: spot-check, monitoring, and record.
  6. Silent sleep monitoring, with data storage and automatic power-saving features for patients with 24 hours of uninterrupted care.
  7. Data can be stored on a computer and managed, analyzed, and printed by using the ODMS system.
 Veterinary Patient Monitor

Application of Veterinary Patient Monitor

Veterinary patient monitors mean multi-parameter medical devices that provide continuous, real-time evaluations of patient vital signs. Widely used in pet hospitals and animal clinics etc. It also is used in the hospital, in clinical environments, home care.

application of  Veterinary Patient Monitor

Specifications of the Veterinary Patient Monitor

Model

  PM6000V

uPM60V

VS2000V

 

Picture

1529723537120817153

1529723565053992962

1529723590640136194

Enclosure

 

Weight

4.85kg (10.69 lb), including 1 battery

280g(0.617lb)with batteries

2.05kg (4.52 lb), including 1 battery

Dimensions

324mm Wx 324mm H x 155mm D

(12.76in. Wx 12.76in. H x 6.10in. D)

78.5mmWx158mmHx31.5mmD (3.09in.Wx6.22in.Hx1.24in.D)

324mm Wx 129mm Hx 183 mmD

(12.76in. W x 5.08in. H x 7.20in. D)

Display

 

Screen size

307.3mm(12.1 in.), measured diagonally

88.9mm(3.5′),measured diagonally

177.8 mm ( 7in.), measured diagonally

Screen type

TFT LCD, white LED backlight,viewing cone of 60° and optimal viewing distance of 1 meter

TFT LCD, white LED backlight

TFT LCD, white LED backlight, viewing cone of 60°and optimal viewing distance of 1.5 meter

Resolution

800x600pixels

320x480pixels

800 x480 pixels

Alarms

 

Categories

Patient status and system status

Patient status and system status

Patient status and system status

Priorities

Low, medium, and high

Low,medium,and high

Low, medium, and high

Notification

Audible and visual

Audible and visual

Audible and visual

Setting

Full storage, low battery and sensor off

Fullstorage,low battery and sensor off

Full storage, low battery and sensor off

Alarm volume level

45 to 85 decibels

45 to 85 decibels

45 to 85 decibels

Alarm system delay

<10seconds

<10seconds

<10 seconds

SpO2

 

Aturation range

1% to 100%

1% to 100%

1% to 100%

Accuracy

70-100% (±2%), <70% undefined

70-100% (±2%), <70% undefined

70-100% (±2%), <70% undefined

Resolution

1%

1%

1%

Display sweep speed

10.00 mm/sec

10.00 mm/sec

10.00 mm/sec

Veterinary Patient Monitor Display

Veterinary Patient Monitor

Why Choose US?

  • On-time Delivery

Our on-time delivery rate is 100%. Delivery time is usually 7-15 working days after payment.

  • Rich Export Experience

Drawell is founded in 1999 and has more than 20 years of exporting experience. We have a professional sales team of around 30 people.

Our main markets are South Africa, the Middle East, Southeast Asia, Europe, etc. So far, we have established business relationships with more than 100 countries.

  • Quick Service

For the before-order stage, our professional sales team will respond to your inquiry within 24 hours whether it is on working days or not.

For the order-running process, we will keep track of your order. You don’t have to worry about the quality or production time.

For the after-sales stage, our technical guidance is free and ready forever. If you have any problems, our after-sales team and engineers will help you solve them, and you will get an answer within 24 hours.