Atomic Absorption Spectrophotometer (AAS/AFS)

aas

Atomic Absorption Spectrophotometer (AAS/AFS)

Atomic absorption spectroscopy, or AAS, is a technique for measuring the concentrations of metallic elements in different materials. As an analytical technique, it uses electromagnetic wavelengths, coming from a light source. Distinct elements will absorb these wavelengths differently. It gives a picture of what concentrations of a specific element there are in whatever material or liquid is being tested.

Atomic Absorption Spectrophotometer also known as Atomic Absorption Spectrometer, is a specific type of spectrophotometer designed for the analysis of the concentration of individual elements in a sample through atomic absorption spectroscopy.

DW-AA320N AAS USER GUIDE

Features of AAS and AFS

For multi-element detection, the specially designed 8-lamp holder supports conventional element memory and allows preheating of 1 to 4 lamps simultaneously. This ensures the light source is always on standby, enhancing ease of use.

AAS Best-Selling Bundled Solutions

How to Choose the AAS Model?

FAAS

Flame Atomic Absorption Spectrometry (FAAS) uses an air/acetylene or nitrous oxide/acetylene flame to evaporate solvents and dissociate samples into atoms. Light from a hollow cathode lamp, based on the element being measured, passes through the atomic cloud, where the element absorbs the light. The detector measures this absorption to calculate the element’s concentration. FAAS operates at a maximum temperature of 2600°C, effective for elements like alkali metals, heavy metals, and transition metals, but less sensitive for refractory elements like V, Zr, Mo, and B due to temperature limitations.

GFAAS

Graphite Furnace Atomic Absorption Spectrometry (GFAAS) operates similarly to FAAS but replaces the flame with an electrically heated graphite tube that can reach up to 3000°C. This increases atom density and residence time, improving detection limits by up to 1000x, achieving sub-ppb sensitivity. However, the performance for refractory elements is still limited due to temperature and graphite cuvette use.

  • Flame: All models available
  • Graphite furnace: DW-220A, DW-AA320N, DW-AA4530F, DW-AA4730FG
  • Hydride generator: Some Special elements like As, Pb, Sn, Se, Hg, Sb, Bi, Ge, Te need to test by AAS with Hydride Generator.

How Does AAS Work?

Principle: Atomic absorption Spectrophotometer (AAS) is based upon the principle that free atoms in the ground state can absorb light of a certain wavelength. Absorption for each element is specific; no other elements absorb this wavelength. It uses a light source that emits a specific wavelength of light, which is then passed through a sample containing the element of interest. The decrease in intensity of the transmitted light is proportional to the concentration of the element.

  1. Use a light source to emit characteristic spectral radiation of the element to be measured
  2. This radiation is absorbed by the ground-state atoms of the element to be measured in the sample vapor produced by the flame atomizer or graphite furnace atomizer
  3. Measure the amount of characteristic radiation absorbed
  4. Calculate the content of the element to be measured based on the functional relationship between the change in light energy and the concentration of the element to be measured (Beer’s law).

Applications of Atomic Absorption Spectrophotometer

Mineral

AAS for Mining

In the mining industry, atomic absorption spectrometry is used to analyse samples and determine if sites have the potential to be profitable. The technique is used to recover precious metals such as gold and silver, as well as resources such as copper and iron ore.

Pharmaceuticals

AAS for Pharmaceuticals

From developing new products to quality control testing, atomic absorption spectrometry is a mainstay in pharmacology laboratories. It can be used to determine if a metal catalyst after a drug has been purified.  For example, AAS is used to ensure antibiotics are free from toxic metals such as platinum and palladium before hitting consumer shelves.

Environmental

AAS for Environmental

The ability to detect miniscule quantities of contaminants and metallic particles has made atomic absorption spectrophotometer a valuable tool used for H2O analysis. It’s used by municipalities to sample drinking water and by environmental scientists to monitor water quality.

Agriculture

AAS for Agriculture

Atomic absorption spectrometry are frequently used in various areas of agricultural research. Typically, they monitor metal contaminants in soil and water, identifying and analyzing potentially harmful elements. 

Forensics

AAS for Forensics

Over the past decade, atomic absorption spectrometry has drastically improved the accuracy of toxicology reports, allowing forensic scientists to detect even the smallest traces of lethal metals such as lead and mercury. The technique is used to analyse muscle and brain tissue, as well as detect gunpowder residue.

Food and Beverage

AAS for Food & Beverage

Even the smallest traces of heavy metals can cause serious health problems when consumed by human. The food, beverage and health supplements sectors rely on atomic absorption spectrometry to test products and ensure they’re safe for consumption.

Archaeology

AAS for Archaeology

The ability to detect trace elements in artefacts makes atomic absorption spectrometry a useful tool for archaeological analysis. It’s used to gain insight into the elemental composition of artefacts, which can reveal information about age, origins and uses.

Products Display

Atomic Absorption Spectrophotometers

Different Applications of Spectrophotometer

Choose the spectrometer series that suits you:

Which Instrument to Choose?

Choose AAS if:

  • You need accurate metals at ppm/ppb
  • Budget is limited
  • You test one element at a time

Choose ICP-OES if:

  • You need multi-element testing (10–40 elements per sample)
  • You want faster throughput
  • You test environmental, mining, chemical, or QC samples

Choose ICP-MS if:

  • You need ultra-trace heavy metals (As, Hg, Pb, Cd)
  • You work in drinking water, food safety, toxicology, high-purity labs

Choose XRF if:

  • You analyze solids, ores, metals, alloys, plating
  • You want non-destructive, zero-preparation testing
  • You don’t need sub-ppm detection in liquids

Choose UV-Vis if:

  • You only need a few metals using reagents
  • Budget is very limited
  • You test Fe, Cr⁶⁺, Cu, Mn, Zn, Ni in water

Why Choose Us for AAS?

Customer Feedbacks:

Other Spectrophotometers

FAQ

We are a factory and can provide OEM services using the customer’s brand. The standard warranty is one year; extensions to the warranty period can be negotiated separately.

We could provide Online instruction; Real-time support by video call or voice chat; During warranty time, we can send product accessories when you need them for free; Technical guidance is free and ready forever.

Flame AAS provides faster and more economical routine metal analysis.

Graphite Furnace AAS provides substantially higher sensitivity and uses electrically heated graphite tubes instead of a flame, making it more suitable for lower-concentration trace analysis.

The DW-220A and DW-AA4730FG are suitable when both atomization modes are required.

The DW-AA4730FG provides an integrated automatic flame–graphite furnace configuration.

Depending on the model, Drawell AAS systems provide from 1 to 8 lamp positions.

Models such as the DW-180B, DW-220A/B, DW-AA4530F and DW-AA4730FG use 8-position lamp systems.

Conventional AAS normally measures one element at a time using the characteristic wavelength of that element.

For laboratories requiring simultaneous measurement of many elements, ICP-OES or ICP-MS may be more appropriate.

Yes, selected AAS systems can be configured with hydride-generation accessories for elements such as As, Se and Hg.

For laboratories primarily focused on these elements at very low concentrations, the DW-AFS310 Atomic Fluorescence Spectrometer should also be considered.

Yes. Autosampler options are available for selected models.

For example, the DW-180B supports an optional 71-position autosampler for automated flame analysis.

Please provide:

  • Target elements
  • Sample type
  • Expected concentration
  • Required detection limit
  • Number of samples per day
  • Required analytical standard or method

Order Process of AAS

order process