PCD100T Benchtop pH/mV/Cond/DO Meter – Touch Screen
PCD100T benchtop pH/mV/Cond/DO Meter(Multi-parameter Meter)can simultaneously measure the pH, conductivity, temperature and dissolved oxygen altogether. It is a multifunctional touch-screen machine.
It can used for soil measurements in agriculture, water quality for municipal water supplies, environmental remediation, pharmaceuticals, food, industry, electric power, scientific research, etc.
Features of PCD100T Benchtop pH/mV/Cond/DO Meter
- With built-in microprocessor chip, intelligent and high accuracy.
- 7″ TFT Touch screen, easy reading and operation.
- With calibration guide, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
- Self-diagnosis functions, automatically recognizing standard buffer solutions.
- Cal points: pH calibration points: 1-5 pts; Cond: 1 pt. DO: 100% Oxygen or Zero oxygen calibration.
- Fast response, stable reading display.
- The kit comes with a combination glass electrode, stainless steel temp probe, and an ATC glass cond. probe.
- IP54 dustproof and spillproof.


Specifications of PCD100T Benchtop pH/mV/Cond/DO Meter
| pH | Range | (-2.000-20.000) pH |
| Resolution | 0.001/0.01 pH | |
| Accuracy | ±0.002pH ±1digit | |
| Cond. | Range | 0~2000.0mS/cm, auto divided by range of: 0~19.999μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm; 200.0~2000mS/cm(K=10)the match test: 0-200.0mS/cm |
| Resolution | 0.001 | |
| Accuracy | ±0.5 % FS±1digit | |
| DO | Range | 0-20.00 mg/L(ppm), 0-200.0 % |
| Accuracy/Resolution | ± 0.30 mg/L;0.01 or 0.1 mg/L | |
| ATC range | (0 – 50)℃ automatically | |
| Salinity compensation | 0~45 ppt manual | |
| Barometric compensation | 0~200 kPa automatically | |
| mV(ORP probe optional) | Range | -1,999mV -+1,999mV |
| Resolution | ± 0.1/1mV | |
| Accuracy | ±0.03% FS ±1digit | |
| Temperature | Range | 0-100°C |
| Resolution/Accuracy | 0.1℃; ±0.2℃ | |
| Data storage | 1500groups | |
| Data Output | USB to Flash DiskUSB to PCWireless connection to printer (the printer is optional) | |
| Power supply | DC12V | |
| Packing including | PCD100T Meter 201G Refillable glass pH probe: 1pc Temp-01 Stainless steel probe: 1pc pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each CON201TG Glass ATC Cond probe, (K=1) Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each DO01-2M Polarographic DO probe, cable length: 2m DOS-01 Membrane refill solution: 30mL,1pc DOSC Sensor caps: 3pcs/group, 1pkg F01 Flexible probe holder: 1pc Magnetic stirrer: 1pc PC cable: 1pc A01 Power adaptor | |