M600L Multi-parameter Analyzer

  • Color High contrast LCD touchscreen, 7.0 inches.
  • Intelligent operation system provides features including user management, calibration management, method management, data management and etc.
  • Multi-reading feature allows auto-read, timed-read and continuous-read.
  • Automatic/Manual temperature compensation ensures accurate results.
  • Data Storage 1000 sets for each parameter (GLP-compliant).
  • Data analysis feature helps user review, compare and recalculate results.
  • Support for USB or RS-232 communication.
  • Reset feature automatically resumes all settings back to factory default options.
  • IP54 waterproof.
  • Support for three modules, namely pH/ISE module, conductivity module and dissolved oxygen module.
  • Select from three modules to customize the four channels your way.
  • Four channels can be configured in any combination.

Features of M600L Multi-parameter Analyzer

pH

  • 1-6 points calibration with Standard Recognition.
  • Selectable pH buffer groups, including NIST, DIN, GB.
  • Support for pH standard group customization.
  • Automatic electrode diagnosis with pH slope and offset display.

Ion

  • 1-6 points calibration
  • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, etc.
  • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
  • Over 10 methods are built-in, including F–, Cl–, Br–, I–, NO3–, BF4–, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

  • 1-5 points calibration with Standard Recognition.
  • Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
  • Temperature compensation type (none, linear, pure water).

DO

  • Support for air-saturated water or zero oxygen calibration.
  • Auto barometric pressure compensation.
  • Manual Salinity Factor Correction.
  • Selectable pressure unit, including kPa, mbar, Torr, Atm.

Includes

  • E-201-L pH composite electrode
  • PF-202-L Fluoride ion selective electrode
  • DJS-1-LEC electrode
  • T-818-L Temperature probe
  • DO-958-L DO electrode
  • NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
  • 1413μS/cm EC standard solution, 50ml, 1 vial
  • REX-3 electrode stand
  • Touch pen

Specifications of M600L Multi-parameter Analyzer

ModelM600L
ParameterspH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)
pHRange-2.000 to 20.000 pH
Resolution0.1, 0.01, 0.001pH
Accuracy±0.002 pH
Calibration PointsUp to 6
Standard CustomizationYes
Calibration ReminderYes
Standard RecognitionNIST, GB, DIN buffers
Slope LimitYes
mV/ORPRange-2000.00 to 2000.00 mV
Resolution0.1, 0.01 mV
Accuracy±0.03%FS 
EH ORP ModeYes
ORP Calibration Points1~2 custom point (relative mV)
pXRange-2.000 to 20.000 pX
Resolution0.1, 0.01, 0.001 pX
Accuracy±0.002 pX
Calibration PointsUp to 6
ISERange1.000e-9 to 9.999e+9
Unitsmol/L, mmol/L, g/L, mg/L, μg/L
ResolutionUp to 4 significant digits
Accuracy±0.3%
Calibration PointsUp to 6
ConductivityRange0.000 μS/cm to 3000 mS/cm
Resolution0.001 μS/cm minimum, various with range selection
Accuracy±0.5% FS
Reference Temperature5, 10, 15, 18, 20, 25 ºC
Calibration PointsUp to 5
Standard Recognition146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm
ResistivityRange5.00 Ω·cm~100.0 MΩ·cm
Resolution0.01 Ω·cm minimum
Accuracy±0.5% FS
TDSRange0.000 mg/L~1000 g/L
Resolution0.001ppm minimum, changed with range
Accuracy±0.5% FS
SalinityTypeNaCl%
Range(0.00~8.00)%
Resolution0.01%
Accuracy±0.1%
DissolvedRange0.00 to 99.99 mg/L
Oxygen Concentration – PolarographicResolution0.01 mg/L
Accuracy±0.1 mg/L
Calibration ReminderYes
Calibration PointsAir-saturated water or zero point
Barometric CompensationYes
Manual Salinity Factor CorrectionYes
% Saturation -PolarographicRange (0.0 to 600)%
Resolution0.10%
Accuracy±2.0%
TemperatureRange-5 to 130 ºC
UnitºC
Resolution0.1℃
Accuracy±0.1℃
MeasurementReading ModeAuto Read (Fast, Medium, Slow), Timed, Continuous
Reading PromptsReading, Stable, Locked
Temp. CompensationATC, MTC
Data managementData Storage1000 Groups
GLP FeaturesYes
Log ManagementYes
InputspH ElectrodeBNC(Q9)
DO with Temp. Probe6-pin Mini-DIN
Conductivity with Temp. Probe8-pin Mini-DIN
OutputsUSB, RS 232USB 2.0 flash memory device, printer, PC
Display optionsBacklightYes
Auto Shutdown1~60 min, off
IP RatingIP54
Date and TimeYes
GeneralPowerAC Adapter, 100-240V AC input, DC24V output
Dimensions280×280×130 mm
Weight2500g (5.51 lb)
Dimensions (Carton)370×305×330 mm
Weight (Gross)4 kg

Other PCD Meter