M510T-A Multi-parameter Analyzer
- Color High contrast LCD touchscreen, 4.3 inches.
- Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.
- Multi-reading feature allows auto-read, timed-read and continuous-read.
- Automatic/Manual temperature compensation ensures accurate results.
- Auto-hold feature senses and locks the measurement endpoint.
- Data Storage 1000 sets for each parameter (GLP-compliant).
- Data analysis feature helps user review, compare and recalculate results.
- Support for USB communication.
- Auto-power off feature effectively extends the battery service life.
- Reset feature automatically resumes all settings back to factory default options.
- IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
Features of M510T-A Multi-parameter Analyzer
pH
- 1-8 points calibration with Standard Recognition.
- Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.
- User-defined pH buffer or buffer group is supported.
- Automatic electrode diagnosis with pH slope and offset display.
Ion
- 1-6 points calibration.
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc.
- Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
- Over 10 methods are built-in, including F–, Cl–, Br–, I–, NO3–, BF4–, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
Conductivity
- 1-5 points calibration automatically recognizes the standard solutions.
- Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
- Temperature compensation type (none, linear, pure water).
Includes
- E-301-QC 3 in 1 pH composite electrode
- DJS-1VTC EC electrode
- NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
- 1413μS/cm EC standard solution, 50ml, 1 vial
- Electrode holder
- Silicone rubber case
- Wristbands
- Touch pen
- Carrying case
Specifications of M510T-A Multi-parameter Analyzer
| Model | M510T-A | |
| Parameters | pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 8 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% | |
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1.000e-9 to 9.999e+9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 8 | |
| Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
| Resolution | 0.001 μS/cm minimum,various with range selection | |
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.0 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000 ppm~1000ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ±0.5% FS | |
| Salinity | Range | 0.0~80.0 ppt |
| Resolution | 0.1ppt | |
| Accuracy | ±1ppt | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1ºC | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC, scanner |
| Display options | Backlight | Yes |
| Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
| IP Rating | IP65 | |
| Date and Time | Yes | |
| General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
| Dimensions | 90×255×40 mm | |
| Weight | 500g (1.1 lb) | |
| Dimensions (Carton) | 490×410×220 mm | |
| Weight (Gross) | 5.5 kg | |