ICP900T Full Spectrum Direct Reading Inductively Coupled Plasma Emission Spectrometer

ICP900T the full spectrum direct reading inductively coupled plasma emission spectrometer is used to determine the content of major, trace, and trace elements in different samples. It can be used for qualitative, semi quantitative, and precise quantitative analysis of elements in samples, with a detection limit of up to one part per billion. Widely used in environmental, food, geological, metallurgical, chemical, petroleum, semiconductor, clinical, and agricultural analysis.

  1. Detection limit: 1-10 ppb
  2. Detection range: 10 ppb to thousands of ppm
  3. Analysis speed: 5-10 elements/minute
  4. Wavelength range: 175nm~900nm, CID detector detection wavelength range: 165nm~900nm

Features of ICP900T Full Spectrum Direct Reading ICP Emission Spectrometer

ICP Element Detection Chart

1. 70+ Elements Testing

70元素

Supports simultaneous multi-element analysis.

2. One Injection, Full Results

多元素

All selected elements measured in a single run.

3. 1 Sample/Min

分析快

Fast analysis for high-throughput testing.

4. ppb-Level Detection

PPB

Achievable for most elements.

5. 5–6 Orders Linear Range

范围

Measures high and low concentrations with one calibration curve.

6. Minimal Chemical Interference

化学物质少干扰

Improves result accuracy and reliability.

Applications of ICP900T Full Spectrum Direct Reading ICP Emission Spectrometer

Application-Metallurgy
Metallurgical industry
The analysis of product ingredients can control the production process and process in real-time,  ensuring the ingredient content of the final product and ensuring the quality requirements of the final product
Application-Geology
Geological and Mineral Industry
Accurately and quickly analyzing the element content in minerals has strict guiding significance for the early mining, mid-term control, and later restoration of mines.
Application-Prescious metal
Precious Metals Industry
The content of impurity elements in precious metals directly affects the purity and performance of precious metals. Accurately measuring the content of low impurity elements is extremely important for the precious metal industry.
Application-Toy
Toy and consumer goods industry
Analyze the heavy metal elements in children’s toys and consumer goods to ensure that the content of heavy metal elements in the products produced is within the control range, making parents feel more at ease.

Environmental protection industry

Accurately and quickly analyze the elemental composition of environmental samples(water quality, soil, atmosphere), providing protection for human daily life.

Rare earth industry

The value and use of rare earth elements are increasingly favored, and the application range of high-purity rare earth elements is also becoming wider. The analysis of impurity elements is particularly important, and the accuracy and efficiency required for rare earth testing can be fully met.

FAQ

Its core advantage is “full-spectrum direct reading.” With a single injection and excitation, it can simultaneously detect all measurable elements in a sample (up to 70), eliminating the need for element-by-element scanning as required by sequential scanning instruments, thus greatly improving analytical efficiency.

The detection limit is very low, with most elements reaching the ppb level (parts per billion), which can meet the analytical needs of trace and ultra-trace elements. It is suitable for the detection of high-purity materials or trace pollutants in the environment.

Very fast. A single spectral line read by the CID (charge injection detector) takes only 2 seconds, and the measurement of all elements in the full spectrum can be completed within 20 seconds. The overall analysis speed can reach one sample per minute.

Yes. The instrument’s linear dynamic range is 5-6 orders of magnitude wide, meaning that elements with high and low concentrations can be detected simultaneously without the need to dilute high-concentration samples or change the standard curve as in traditional methods, making operation simpler.

It has a very wide range of applications, covering environmental protection (water/soil/air), metallurgy (process control), precious metals (impurity analysis), geology and minerals (exploration), toys/consumer products (heavy metal safety screening), rare earths (high-purity rare earth impurity detection), as well as food, petrochemicals, semiconductors, and other fields.

Excellent stability. The relative standard deviation (RSD) of a 2-hour long-term test is <1%. Furthermore, the optical chamber is equipped with a distributed precision temperature control system (35±0.1℃), which effectively eliminates the impact of ambient temperature changes on the optical system, ensuring long-term data reliability.

It uses a Thermo CID (charge injection detector) imported directly from the USA. Its features include: no chip coating required; quantum efficiency of up to 35% in the 200nm ultraviolet region; and efficient three-stage semiconductor cooling with a cooling temperature down to -45℃, greatly reducing dark current noise.

Yes. The instrument offers a variety of nebulizer and torch models, and can be equipped with specialized sample introduction components resistant to high salt and hydrofluoric acid (HF) to meet specific customer needs, making it highly adaptable.

Not high. The total argon gas consumption is less than 14 L/min, which is relatively economical compared to similar instruments, helping to reduce daily operating costs.

Very easy. The software supports qualitative, semi-quantitative, and precise quantitative analysis modes, offering comprehensive functionality. The torch uses a tri-concentric quartz torch design with an outer diameter of 20mm, and various models are available, making replacement and maintenance relatively quick.

Specifications of ICP900T Full Spectrum Direct Reading ICP Emission Spectrometer

Input power supplyAC 220V, current 20A
Input power700-1500W
Power EfficiencyGreater than 70%
Output power stability<0.01%
Power frequency27.12MHz
Frequency Stability<0.01%
Observation methodVertical observation
StabilityRelative standard deviation RSD<l% @ 2 hours
Element detection limit (ug/)Most elements range from lppb to 10ppb
Repeatability(i.e. short-term stability) relative standard deviation RSD<0.5%%
Test speedThe reading time of a single spectral line CID is only 2 seconds,  and all elements can be measured within 20 seconds
Output working coilsilver plated high-firequency coil with an inner diameter of 25mm and 3 turns
Total argon consumptionThe total argon consumption is less than l4L/min
Atomization chamberDouble tube atomization chamber,  optional with swirl atomization chamber
Peristaltic pumpfive channels and sixteen rollers,  with adjustable speed according to the required flow rate
Three concentric quartz torch tubeouter diameter 20mm; Multiple models available in different industries
Efficient imported atomizerconcentric circular atomizer with an outer diameter of 6mm,  Multiple models available,  high salt,  Hf resistant,  etc
Detector typeAmerican original Thermo Charge Injection Detector (CD)
Target size27.6×27.6mm,1024
Quantum efficiencyNo coating,  up to 35% in the 200nm ultraviolet region
Detector coolinghigh-efficiency three-level semiconductor cooling,  cooling temperature -45℃
Reading methodsNon destructive reading (NDRO),  full amplitude reading (F),  and arbitrary read integration (RAI)
Gratingmedium stepped grating,  52.67lp/mm,  64° flare angle
Light chamberdistributed precision constant temperature,  35 + 0.1 °
Prismultrapure Corning ultraviolet fused silica,  with filtration greater than 99% at 170nm
Stray lightEquivalent background concentration of 10000ppmCa solution at As189.042nm<2ppm

Standard configuration

SerialNumberAccessory NameQuantityUnitSpecification And ModelNotes
OneStandard Configuration    
1Host    
1.1Inductively coupled plasmaemission spectrometer1Set  
2Software    
2.1ICP spectrometer analysissoftware1SetFree upgrade 
3Accessory    
3.1Network cable1Piece3m 
3.2Plastic bucket1PieceVolume 5L 
3.3Argon pressure reducing valve2PieceAR-8 
3.4PU hose30Meter10×6.5×1.75mm 
3.5PU hose5Meter6×4×1mm 
3.6PVC transparent hose1Meter8mm×6mm Transparent hose 
3.7Power cord1Piece10A,250V 
3.8USB extension cable1PieceLength 3m 
3.9Grounding copper wire15MeterSectional area 4mm² 
3.10Ground rod1Piece18*800 
3.11Torch tube2Piece1.5 quartz torch tube 
3.12Double tube fog chamber1PieceScott fog chamber 
3.13Cylindrical fog chambercover1PiecePolytetrafluoroethylene 
3.14Atomizer1PieceQuartz atomizer 
3.15Wavelength calibration solution1Bottle1000ml 
3.16High-frequency coil component1PieceThree turns ,silver plating 
3.17Capillary sample tube1MeterD=2.38mm,d=0.8mm 
3.18Peristaltic pump head hose3PieceФ1.65,Length 45cm,Two clamps 
3.19Tubular fuse2Piece10A,250V,6×30mm 
3.20Tubular fuse2Piece6.3A,250V,5×20mm 
3.21Silicone tube4MeterInside diameter 2mm,Outside diameter 4mm,Hardness 55 
3.22Hose adapter4PieceZCJH-2*6 direct connection,Inside diameter 6-2 
3.23Hose adapter4PieceZC-1/16*3/32,Inside diameter 1.6-2.4 
3.24Spherical interface clamp1PieceL00091181,Ø=10 
3.25Quick coupling3PieceΦ6 
3.26Teflon tape1RollThickness:0.1~0.2mm 
3.27O-ring seal4Piece32.5×3.55 
3.28O-ring seal8Piece5.6×1.8 
3.29Torch pipe tooling1PieceCylinder 
3.30Nylon cloth ventilation duct10MeterGrey,Inside diameter 125mm 
3.31Stainless steel pipe clamp2Piece118-140mm 
3.32Ribbon50Piece4×200 
3.33Screw5PieceM5,Cross dischead 
3.34Screw5PieceM4,Cross dischead 
3.35T-shaped tee2Piece10-10-10 
3.36Filter tank filter element4PieceOutside diameter:60mm,Inside diameter:28mm,Length:125mm 
4Standard Configuration    
4.1Computer1SetBrand 
4.2Monitor1SetBrand 
4.3Printer1SetBrand 
4.4Cooling water tank1Set  
4.5Regulated power supply1Set  
5Delivery Attached Documentation    
5.1U disk1Piece  
5.2Product quality certificate1PieceEnglish 
5.3Warranty card1PieceEnglish

Consumables

No.NameSpecificationReplacement cycle
1TorchQuartz torchClean and maintain once every 3 months.Service life 2 years
2NebulizerImport GE nebulizerNon-human damage over 3 years
3Spray chamberDouble-tube spray chamberNon-human damage over 3 years
4Peristaltic Pump Head HoseInjection and Drain Tubing3 Months
5High- frequency coilSilver-plated, three-turn coilOne year
6Filter elementPP cotton materialHalf a year

Optional Autosampler

AS Control II Disc Automatic Sampler-43cup

  1. Sample tray: 43 cup sample tray, corrosion-resistant material, lightweight.
  2. Sample Cup: Sample cup capacity 45ml,Reagent cup capacity 45ml
  3. Syringe: High quality carbon fiber tube φ4× φ2.5; Polytetrafluoroethylene tube φ2×0.5mm
  4. Automatic fluid replacement and cleaning: Automatically provide cleaning solution without manual addition
Autosampler 272 cup

AS Control II Disc Automatic Sampler-272cup

  1. Sample tray: 272 cup sample tray,corrosion-resistant material,lightweight
  2. Sample Cup: Sample cup capacity 15ml
  3. Syringe: High quality carbon fiber tube φ4×φ2.5; Polytetrafluoroethylene tube φ2×0.5mm
  4. Automatic fluid replacement and cleaning: Automatically provide cleaning solution without manual addition

Customer Service of ICP900T Full Spectrum Direct Reading ICP Emission Spectrometer

ICP900T Inductively Coupled Plasma Emission Spectrometer

Why Choose Us?

One-Station Shopping

“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem.

Customer-centric Services

User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country.

Online Support

To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.

100% Quality Guarantee

1-year free warranty includes repairing damaged parts and replacing selected ones (shipping extra). 5% is charged to extend it before it expires.

Other ICP Products