DWT-B Pulsating Vacuum Table Top Steam Sterilizer
DWT-B desktop pulsating vacuum sterilizer complies with European CLASS B standard, adopts 3 pre-vacuum cycles for thorough air removal, built-in drying function, supports BD/Helix/Vacuum test, with printer & USB data storage, ideal for dental, medical, vet, beauty and lab sterilization of wrapped/hollow instruments.
- 8L/12L/18L/23L: EU Class B sterilization.
- 3 times Pulsating Vacuum: For wrapped and hollow loads.
- Smart Control: LCD Touchscreen, auto filling, printer, and USB export.
- 5-Level Safety: Built-in verification programs.
Features of DWT-B Pulsating Vacuum Table Top Steam Sterilizer
- Quality stainless steel inner tank, sealed cover.
- Microcomputer control
- Safety interlocking device
- Automatic water
- With drying function
- With BD test, HELIX test, and VACUUM test.
- LCD display and touch buttons.
- European CLASS B standard.
- With automatic protection function: over temperature protection, overpressure protection, low water level protection, anti-dry burning, and safety door lock.
- 3 times per-vacuum
- Buzzer reminder after sterilization, automatic stop.
- Automatic discharge of cold air, and automatic steam exhaust after sterilization.
- Built-in steam generator to provide saturated steam quickly.
- With printer, USB function, and U disk.
Applications of DWT-B Pulsating Vacuum Table Top Steam Sterilizer
- Dental Clinic Dental Instruments: Dental Clinic Dental Instruments: Sterilize dental mirrors, extraction forceps, scalers and impression trays to eliminate bacteria for safe dental diagnosis and treatment.
- Outpatient Clinic Surgical Tools: Outpatient Clinic Surgical Tools: Disinfect surgical scissors, vaginal speculums, tweezers and reusable examination instruments for daily outpatient diagnosis.
- Tattoo & PMU Beauty Tools: Tattoo & PMU Beauty Tools: Fully disinfect microblading pens, tattoo grips, piercing clamps and beauty extractors to avoid cross infection in beauty & tattoo studios.
- Veterinary Pet Medical Equipment: Veterinary Pet Medical Equipment: Sterilize pet surgical forceps, nail trimmers, veterinary probes and trimming tools to prevent cross infection for animal treatment..
- Laboratory Glassware & Culture Medium: Laboratory Glassware & Culture Medium: Sterilize petri dishes, flasks, test tubes and microbial culture medium to meet biosafety experiment standards.
Display of DWT-B Pulsating Vacuum Table Top Steam Sterilizer
FAQ
Specifications of DWT-B Pulsating Vacuum Table Top Steam Sterilizer
| Technical parameter / Model | DWT-8B | DWT-12B | DWT-18B | DWT-23B |
| Volume | 8L | 12L | 18L | 23L |
| Power | 2kw | 2kw | 2kw | 2kw |
| Voltage | 110V/220V,60Hz/50Hz | |||
| Design pressure | 0.25MPa | |||
| Design temperature | 139℃ | |||
| Rated working pressure | 0.22MPa | |||
| Rated working temperature | 134℃ | |||
| Chamber volume | Φ170×320 | Φ200×355 | Φ250×370 | Φ250×452 |
| Outer dimension | 445×580×400 | 445×580×400 | 480×640×450 | 480×690×450 |
| Packing size(L×W×H) | 650×500×450 | 650×500×450 | 720×560×510 | 760×560×510 |
| Gross/net weight | 45/42kg | 48/44kg | 57/48kg | 60/53kg |
Customer Service of DWT-B Pulsating Vacuum Table Top Steam Sterilizer