DWT-A Series Table Top Steam Sterilizer
DWT-A desktop autoclave complies with European CLASS N standard, microcomputer full automatic cycle, supports 121℃/134℃ dual temperature, built-in steam generator, perfect for dental clinics, labs and medical offices.
- 18L & 23L two capacities, European CLASS N standard certification
- Touch control + auto cold air removal, auto exhaust after sterilization
- Multi safety protection & dual voltage 110V/220V for global sales
Features of DWT-A Series Table Top Steam Sterilizer
- Stainless steel inner tank with sealed cover; two sizes: 18L(Φ250×370mm) / 23L(Φ250×452mm).
- Adjustable 121℃ & 134℃, rated working pressure 0.22MPa, design pressure 0.25MPa, max temp 139℃.
- Touch buttons, full automatic cycle, built-in steam generator for fast saturated steam output.
- Meets EU CLASS N standard, reserved standard test interface for verification.
- Auto cold air discharge, auto steam exhaust; buzzer alert & auto stop after cycle finished.
- Over-temperature, over-pressure, low water level & anti dry burning auto protection.
- 110V/220V 50/60Hz optional; power 1.5KW(18L)/2KW(23L), compact desktop size.
Applications of DWT-A Series Table Top Steam Sterilizer
- Dental Clinic Dental Instruments: Dental Clinic Dental Instruments: Sterilize dental mirrors, extraction forceps, scalers and impression trays to eliminate bacteria for safe dental diagnosis and treatment.
- Outpatient Clinic Surgical Tools: Outpatient Clinic Surgical Tools: Disinfect surgical scissors, vaginal speculums, tweezers and reusable examination instruments for daily outpatient diagnosis.
- Tattoo & PMU Beauty Tools: Tattoo & PMU Beauty Tools: Fully disinfect microblading pens, tattoo grips, piercing clamps and beauty extractors to avoid cross infection in beauty & tattoo studios.
- Veterinary Pet Medical Equipment: Veterinary Pet Medical Equipment: Sterilize pet surgical forceps, nail trimmers, veterinary probes and trimming tools to prevent cross infection for animal treatment..
- Laboratory Glassware & Culture Medium: Laboratory Glassware & Culture Medium: Sterilize petri dishes, flasks, test tubes and microbial culture medium to meet biosafety experiment standards.
DWT-A Series Table Top Steam Sterilizer Display
FAQ
Specifications of DWT-A Series Table Top Steam Sterilizer
| Technical parameter / Model | DWT-18A | DWT-23A |
| Volume | 18L | 23L |
| Power | 1.5kw | 2kw |
| Voltage | 110V/220V,60Hz/50Hz | |
| Design pressure | 0.25MPa | |
| Design temperature | 139℃ | |
| Rated working pressure | 0.22MPa | |
| Rated working temperature | 134℃ | |
| Chamber volume | ∅250×370 | ∅250×452 |
| Outer dimension | 500×400×350 | 600×400×350 |
| Packing size(L×W×H) | 540×450×390 | 640×450×390 |
| Gross/net weight | 26/24kg | 29/27kg |
Customer Service of DWT-A Series Table Top Steam Sterilizer