LW8548 AD Laboratory Glassware Washer

The LW8548AD laboratory glassware washer and dryer is capable of washing glassware with 3-tier racks and has a small footprint. It is a highly cost-effective option for high throughput or mixed loading processing. It is suitable for cleaning and disinfecting laboratory vessels made of various materials, including glass, ceramics, metals, plastics, etc. Examples of these vessels include test tubes, beakers, volumetric flasks, measuring cylinders, flat bottom flasks, burettes, filter funnels, centrifuge tubes, reagent bottles, pipettes, capillary tubes, and so on. It provides strong cleaning and glassware drying functions, and needs to be installed independently.

LW8548 AD Laboratory Glassware Washer 4
LW8548 AD Laboratory Glassware Washer
  • Washing and forced hot air drying system on four independent levels. The two upper levels can be placed at either one of three different water/air connections depending on the height of the loaded glassware.
  • High visibility hinged full glass door
  • Sliding drawer for storage of chemical containers (up to three 5 L)

Key Features

Flexible Solutions

Up to three different levels with four possible rack locations for maximum flexibility. Removing the upper levels the unit can be used to clean large bottles and carboys of volume up to 60 L.

Steam Condenser

As standard, the LAB 500 series is equipped with an integrated steam condenser to prevent vapors from entering into the washing area at a set temperature – programmable from 0°C to 93°C.

User-Friendly Control Panel

High safety and easy to use soft touch control system on glass panel with LCD color display to visualize cycle status, allowing for 40 programming options.

Drying Efficacy

Built-In HEPA 14 filtered forced air drying system providing even and fast drying of surgical instruments. Adjustable time and temperature settings for the optimization of cycle duration and energy consumption.

Easy Access to Chemicals

A frontal sliding drawer for easy access and storage of chemical containers – up to three 5 L.

Conductivity Sensor

Conductivity sensor for measuring of the conductivity value during the final rinse phase are available upon request.

LW8548AD Technical Data

Washer Model
Washer ModelLW8548AD
Door Opening1 Vertical Sliding Door
Door With Glass Window1
Chamber Levels4 Levels
Chamber MaterialAISI 316L
Externa MaterialAISI 304
Size and Weight
Externa672 ×660×1835mm
Chamber26 0 L
Weight(kg)30 0 KG
Performance Data
Circulation Pump8 00 L/Min
Max.Temperature93 ℃
Min.Temperature20 ℃
Water Consumption20L/Step
Detergent Capacity6 L
Minimum Run Time40Min
Control System
Electronic ControlPL C( Programmable logic controller )
Display Screen7 Inch LCD Display
Standard Program20
User Program20
Login Password3 levels,6 Accounts
Operating LanguageChinese, English, Russian, Spanish
Drying Device
Hepa H14 Air FlterHepa H14 Air Flter
Filter Efficiency99.999%
Fan Power0.9KW
Electrical Power3KW
Power Supply
Electrical connectionsAC 380V 50HZ
Electrical Power9 KW
Total power10 KW
Water Connection/Drainage
Cold Water Pressure200-500 KPa
DI Water Pressure0-500 KPa
DI Water Quality5.0μs/cm
Drain Wemperature (max.)75 ℃
Drain Drate(max.)20L/Min
Noise
Noise75Bel

LW8548AD Laboratory Glassware Washer Display

Other Laboratory Glassware Washer