DW-XRD-Y3500 X-ray Diffractometer

The new high-end X-ray diffractometer (XRD) is a domestic high-performance and high-precision XRD, which is the project of the National Development and Reform Commission. With advanced core technology, it can accurately do qualitative and quantitative phase analysis of metal and non-metallic polycrystalline samples. It can be mainly used in qualitative or quantitative analysis, crystal structure analysis, material structure analysis, macroscopic or microscopic stress determination, crystal size determination, crystal size determination, crystallinity determination, etc., therefore, It is widely used in many disciplines and industries: materials science, physics, chemistry, chemical industry, metallurgy, minerals, drugs, building materials, ceramics, etc.

The new high-end X-ray diffractometer (XRD) is a domestic high-performance and high-precision XRD, which is the project of the National Development and Reform Commission. With advanced core technology, it can accurately do qualitative and quantitative phase analysis of metal and non-metallic polycrystalline samples. It can be mainly used in qualitative or quantitative analysis, crystal structure analysis, material structure analysis, macroscopic or microscopic stress determination, crystal size determination, crystal size determination, crystallinity determination, etc., therefore, It is widely used in many disciplines and industries: materials science, physics, chemistry, chemical industry, metallurgy, minerals, drugs, building materials, ceramics, etc.

Base on this standard configuration, if we install related accessories, it can do analysis structure of thin films, texture of metal materials, stress measurement,and material structure under high and low temperature.

Within the most advanced technology at present, the accuracy of the goniometer had reached the current world advanced level. The X-ray source and detector can work stably for a long time to ensure the accuracy of measurement of diffraction peak position, peak shape and intensity. Phase structure analysis, including: phase content, grain size judgment, crystallinity, austenite content, cell measurement, second class stress calculation, diffraction line indexing, phase structure analysis,thin film material analysis, small angle particle size analysis, etc. DW-XRD-Y3500 includes high-stability X-ray generator, high-precision goniometer, scintillation detector, data processing software, and related application software.

Features of DW-XRD-Y3500

  • High-frequency and high-voltage X-ray source: Solid X-ray generator greatly improves the stability of the measurement results of the XRD;
  • Long life X-ray tube: metal ceramic X-ray tube, with good heat dissipation, high operating power (40kV×40mA), long service life;
  • High precision goniometer: It is controlled by optical coding technology. Based on the traditional turboworm transmission technology, incremental optical coding technology is adopted. The optical digital coding can directly read the angle from both arms (invention patent), which greatly improves the accuracy and repeatability of the goniometer. The new generation of direct optical coding systems ensures the accuracy of the goniometer over the life of the instrument through the accurately calibrated Heidenhain optical encoder and trajectory tracking technology.

The goniometer adopts “coaxial &different core” technology to avoid the interference between the arms during scanning, ensuring the accuracy and stability of the goniometer.

  • Multiple XRD accessories: high temperature, low temperature, multi-function and other XRD accessories installation to achieve “plug and play”, software automatic identification control technology, convenient for operators to use the instrument;
  • Safe X-ray protection: X-ray scattering line protection device is more safe and reliable, the X-ray protection door is forbidden to open when the sample is measured, and double protection can avoid the operator from scattering line radiation under any circumstances.
DW-XRD-Y3500 X-ray Diffractometer display

Parameters of DW-XRD-Y3500

Model DW-XRD-Y3500
High frequency high voltage solid X-ray generator
Maximum output power 3kW
Tube voltage 10 ~ 60KV, 1kV/step
Tube current 5 ~ 50mA, 1mA/step
Beam voltage stability Better than ±0.005% (when the external voltage fluctuates 10%)
X-ray tube Metal-body ceramic X-ray tube
Focus size Focus 1×10mm
Standard target Cu target (other target is optional)
Ray tube power 2.4kW
High precision goniometer
Goniometer Vertical type,θ/θ,sample is placed horizontally
Using incremental coded reading technology
Diffraction circle radius 180mm ~ 300mm
Scanning mode continuous, step-by-step
2θ Measuring range -110°~ 168°
Minimum step Angle 0.0001°
Maximum rotational speed 20°/s
Diffraction Angle measurement linearity ≤0.01°
Full spectrum Angle measurement accuracy ±0.005°
Beam size 180×180μm
Resolution ≤0.028° (2θ center)
Repeatability error ±0.0001°
Angle reproducibility 0.0001°
Maximum positioning speed ≤1200°/min
Diffraction angular linearity The angular deviation of all peaks in the full spectrum does not exceed ±0.01°.
Detector
Scintillation detector It Works with monochromator to effectively remove the Kβ line
Maximum linear count ≥5×105CPS
Spectral resolution ≤50%
Curved crystal graphite monochromator When testing the sample, a monochromator is required to effectively remove the Kβ line, and the reflection efficiency is ≥28%
Control and data processing software
Computer Control and data processing software running under the Windows10 operating system.
Application software Phase qualitative, quantitative analysis, Kα1, α2 stripping, full spectrum fitting, peak selection fitting, half-height width and grain size calculation, cell measurement, secondary stress calculation, diffraction line index, multiple plotting, 3D plotting, diffraction data calibration, background deduction, quantitative analysis without standard sample, full spectrum fitting (WPF), XRD diffraction pattern simulation.
Overall dimensions 1320×1150×1860mm

Working Condition of DW-XRD-Y3500

  1. Working temperature: 10℃ ~ 30℃.
  2. Ambient relative humidity: ≤80%.
  3. Power supply: unidirectional, AC 220V, 50HZ, power supply voltage fluctuation does not exceed the rated voltage -10% ~ +10%, power capacity is not less than 5kVA.
  4. There should be a good grounding device, grounding resistance is not more than 4Ω.
  5. Cooling system: Independent self-circulating refrigeration system, using pure water.
  6. The power supply line shall not have arc and high-frequency interference caused by welding machines, high-frequency furnaces and other equipment.
  7. The surrounding environment should not have flammable and corrosive gases, and try to avoid dust and vibration.

Protection system

The protection system is safe and reliable, with machine and door interlocking mechanism. When operator open the door, at the same time the shutter stops working. This function can avoid the operator from being exposed to scattered ray radiation. The radiation dose < 0.2μSv/h. 

Configuration List of DW-XRD-Y3500

Part Name Unit Qty Remark
X-ray generator ①AL20 High-frequency high voltage generator Set 1 solid state
②XD3560 High voltage cable(100kVP) Piece 1 Length:3m
③XD3510 Tube sleeve(includes auto-shutter) Set 1  
④XD3520 Auto-control unit Set 1 power cable 1 piece
⑤XD3530 Cabinet Set 1 Lead+ lead glass
⑥AL3540 Metal ceramic insulated X-ray tube Piece 1 Cu target 2.4kW
Goniometer ①XD3502 goniometer (θ-θ structure) Set 1  
②Slit, powder sample stage Set 1 1 set for each
③Through hole sample holder Piece 10 Quartz matrix
④Blind hole sample holder Piece 30 Quartz matrix
⑤filter Piece 1 Match with the target
⑥X-ray path adjustment accessories Set 1  
Record control unit ①Scintillation counter Set 1  
②Recorder-controller Set 1  
③Electrical machinery& communication cable Set 1 2 motor cables, 1 communication cable
④Power system Set 1  
Cooling system ①AL3 Circulating water cooling device Set 1 unibody construction
②Cooling water connection pipe Piece 2  
PC ①Intel i Series processor, 8G memory, 256G SSD, 24-inch LED display Set 1 Dell
②A4 laser printer Set 1  
Control& application software ①AL series XRD control software Set 1 Windows11
②XRD data processing software Set 1  
③Diffraction data card base Set 1  
④Crystal Structure Data Base Set 1  
Documents ①User Manual Copy 1  
②Water cooling system instruction Copy 1  
Spare parts ①Fuse 1、2、3、5、10(A) Piece 10 10 for each
②Tool Set 1  
③Agate mortar Φ100 Set 1  
④Graphite monochromator Set 1 Reflectivity >28%