DW-FTIR-530A FT-IR Spectrometer
The DW-FTIR-530A FTIR Spectrometer is designed for routine material identification, quality control and laboratory analysis of powders, polymers, films, liquids, oils and gases. Its stable Michelson interferometer and flexible sampling accessories provide reliable FTIR analysis with low routine maintenance.
- S/N Better than 20,000:1
- 7800–350 cm⁻¹ Spectral Range
- 0.85 cm⁻¹ Resolution
- ±0.01 cm⁻¹ Wavenumber Accuracy
- Transmission · ATR · Liquid · Gas · Reflection
Innovations of DW-FTIR-530A FT-IR Spectrometer
- Real-time diagnosis of instrument status: real-time monitoring of instrument working status, performance and communication status.
- Multiple detector options. Besides conventional normal temperature pyroelectric detectors, temperature-stabilized pyroelectric detectors and semiconductor refrigeration MCT detectors can also be selected to meet the needs of different customers.
- “Wire + Wireless” multi-communication mode. Adopting Ethernet and WIFI dual-mode communication to adapt the development trend of “Internet + testing” instruments. Building a basic platform for users to conduct interconnection testing, remote operation, and maintenance, data cloud computing, etc.
- Large sample room. With the large sample chamber design, besides the conventional liquid pool, ATR, and other commercially available conventional accessories, it can also be equipped with special accessories such as thermal red combination, microscope, etc. At the same time, it also reserves space for users to choose new accessories
Brand-new Powerful Main FTOS Suite Software Workstation



Features of DW-FTIR-530A FT-IR Spectrometer
1. Stable Optical System
Cube-corner Michelson interferometer with patented fixed mirror alignment technology ensures long-term optical stability without complex dynamic alignment. Gold-coated mirrors improve light throughput and detection sensitivity.
2. Robust Modular Structure
Compact modular design on a cast aluminum base improves mechanical strength, heat dissipation, vibration resistance, and long-term working stability.
3. Moisture-Proof Optical Protection
Multi-sealed interferometer design, large-capacity desiccant cartridge, visible desiccant window, and real-time temperature/humidity monitoring help protect the optical system from humidity and chemical corrosion.
4. High-Performance Electronic System
Integrated electronics with pyroelectric detector pre-amplifier, dynamic gain amplification, 24-bit A/D conversion, digital filtering, and network communication ensure stable real-time data collection and fast transmission.
5. Strong Anti-Interference Design
The electronic system is designed to meet CE and electromagnetic compatibility requirements, reducing electromagnetic interference and improving data reliability.
6. High-Intensity IR Source
Long-lifetime air-cooled IR source with strong energy distribution in the fingerprint region provides stable infrared radiation and better thermal stability for repeatable FTIR analysis.
Applications of DW-FTIR-530A FT-IR Spectrometer




Extend FTIR Analysis with TGA–FTIR
DW-FTIR-530A / DW-FTIR-530Pro can be configured with the BXT-TGA-101 Thermogravimetric Analyzer for TGA–FTIR evolved gas analysis. The TGA records when and how much the sample loses weight during heating, while FTIR helps identify the gaseous decomposition products released at each stage.
Useful for studying polymers, rubber, additives, organic materials, environmental samples and thermal decomposition mechanisms

Operation and Maintenance Tips
For stable performance, install the DW-FTIR-530A in a clean, temperature-controlled laboratory. Recommended working conditions are 10–30°C with humidity below 60%. For longer service life, keep the optical system dry, replace desiccant when needed, avoid corrosive gases near the instrument, and use a moisture-proof box and dehumidifier in humid environments.

DW-FTIR-530A FTIR Spectrometer Picture
DW-FTIR-530A vs DW-FTIR-530Pro
| DW-FTIR-530A | DW-FTIR-530Pro | |
| Positioning | Routine QC | Advanced QC & Research |
| S/N | >20,000:1 | >40,000:1 |
| Standard Detector | Pyroelectric Module | DLATGS |
| Resolution | 0.85 cm⁻¹ | 0.85 cm⁻¹ |
| Spectral Range | 7800–350 cm⁻¹ | 7800–350 cm⁻¹ |
| Best For | Routine Identification | Higher-Sensitivity Applications |
Need Higher Sensitivity? View DW-FTIR-530Pro →
FAQ
Why Choose Us?
One-Station Shopping
“Multiple suppliers” have always been an issue in the procurement process. Drawell as a one-stop laboratory equipment and scientific instruments supplier, can perfectly solve this problem. In addition to manufacturing our own equipment, we also represent other laboratory equipment. Our product lines are rich and diverse at competitive prices. Provide one-stop service to customers.
Customer-centric Services
User Training – Training by Drawell skilled engineers about installation, debug tests, technical services, etc. It can happen in our factory in China, or at the site in the customers’ country. Cost depends on where and when the training happens.
Online Support
To discuss the problem and get it resolved, online chats, real-time video calls, and remote guidance. For the after-sales stage, our online technical guidance is free and ready forever.
100% Quality Guarantee Policy
1 year free official warranty, including repairing quality-damaged parts, and offering replacements of selected parts (shipping cost is extra). 5% of the product price is charged for extending the warranty before the end of the official warranty.