Automatic Potential Titrator Ti-51
General Features
- Color High contrast LCD touchscreen, 7.0 inches.
- Potential titration and measurement of pH, pX, ion concentration.
Smart Operation Auto-recognition High Throughput
- Intelligent operation system provides features including user management, method management, sensor management, titrant management, data management and GMP management etc.
- User four-level authority management and password management.
- Method management function, built-in titration method (potentiometric titration method 200 sets) and measurement method (direct reading concentration method, known increment method, GRAN method), support custom method.
- Connection with auto sampler to realize the automatic measurement and batch detection of samples.
Titration
- Detection module expansion of dead stop titration, conductometric titration, photometric titration and temperature
- titration analysis.
- Replaceable burette with high-accuracy (5mL, 10 mL or 20 mL selectable).
- 1 extra burette driver can be installed (optional), support for dosing or titration.
- Burette line using acid and alkali resistance, perchloric acid resistance, organic reagent corrosion resistant material, can be non-aqueous titration.
- Support upper mixer and lower mixer.
- Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point
- titration), SET (Preset Endpoint Titration) ,constant pH titration, constant speed titration, Blank titration, and MAT (manual titration).
- Support acid-base titration, non-aqueous phase acid-base titration, REDOX titration, precipitation titration and complex titration and other titration methods.
- Displays the test method, titration curve and measurement results in real time.
- Formula editor can display calculation results directly.
- Supports recalculation of original data.
pH
- 1-3 points calibration with Standard Recognition.
- Selectable pH buffer groups, including NIST, DIN, GB.
- Automatic electrode diagnosis with pH slope and offset display
Ion
- 1-3 points calibration.
- Selectable measurement unit, including μg/L, mg/L, g/L, mmol/ L, pX, ppm and ppb.
- Measurement modes are supported, including Direct Reading mode, Standard Addition mode, and GRAN mode.
- Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3 – , BF4 – , NH4 + , K+ , Na+ , Ca2+, Cu2+, Pb2+, Ag+ , etc. User-defined method is supported.
Data management, Audit trial
- Data Storage 1000 sets for each parameter (GLP-compliant).
- Support for GMP management, the GMP logs achieve the tracking and analysis of the the data.
- Support for RS-232 communication for print and the print format can be alternate.
- Support for USB communication for PC software.
- Support for U disk for method export and import.
- Support for U disk for data export with CSV or PDF format.
- Support for barcode scanner and balance(Specific model).
- It needs GMP software to implement GMP management functions.
Includes
- 10mL burette
- 231-01 pH indicator electrode
- 213-01 platinum electrode
- 216-01 silver electrode
- 232-01-D reference electrode
- 217-01-D reference electrode
- T-818-Q Temperature probe
- NIST pH standard powder(4.01, 7.00, 10.01)
Specifications of Ti-51 Potential Titrator
| Model | Ti-51 | |
| Repeatability | ≤0.2% | |
| Burette | Accuracy | 5mL Burette:±0.010mL 10mL Burette:±0.020mL 20mL Burette:±0.030mL |
| Resolution | 1/480000 | |
| Measuring Unit | Range | (-2000.00~2000.00)mV (-5.000~20.000)pH pX:(-2.000~20.000)pX lon:(1.000e-9~9.999e+9)μg/L, mg/L,g/L,mol/L,mmol/L,ppm,ppb |
| Resolution | pH:0.001pH pX:0.001pX lon:Up to 4 significant digits mV:0.01mV | |
| Accuracy | pH:±0.002pH mV:±0.03%or ±0.2mV | |
| Fluctuation | ±0.3mV/3h | |
| Repeatability | ≤0.1mV | |
| Temp. Compensation | Range | (-10.0~135.0)℃ |
| Resolution | 0.1℃ | |
| Accuracy | ±0.1℃ | |
| General | Power Supply | (80~250)VAC,(47~63)Hz |
| Dimensions | 240×370×270 mm | |
| Net Weight | About 4 kg | |