Oil Melting Point Instrument Series

Automatic oil automatic precise measuring instrument for melting various oil product melting points, good navigation mechanical grease instrument of melting the perfect combination of high precision Peltier temperature control technology and high-definition video camera technology, not only provides the test result is accurate, stable, and reliable for users, but also bring the test experience efficient and convenient for users. Peltier temperature control technology can realize high precision temperature control, high-definition video can conveniently and clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point, reducing the labor intensity of the staff, convenience for the user to measure the melting point of the sample accurately.

The Main Technical Indicators of JHY30 & JHY50

ModelJHY30JHY50
Temperature control rangeRT-100℃6-100℃
Detection methodSemi-automaticSemi-automatic
Capacity per batch2pc./batch2pc./batch
Temperature resolution0.1℃0.1℃
Temperature gradients(0.1-10.0)℃/Min(0.1-10.0)℃/Min
Temperature accuracy±0.3℃±0.3℃
Repeatability0.1℃/Min时±0.1℃0.1℃/Min时±0.1℃
Camera&VideoCameraCamera&Video
Video playback—YES
Operator account—8
Result storage200400
SD card capacity8G8G
DisplayTFT Touch screenTFT Touch screen
InterfaceUSB RS232 SD card EnternetUSB RS232 SD card Enternet
Opening capillary sizeI.D>1.0mm,O.D.1.4mmI.D>1.0mm,O.D.1.4mm
Double openingDouble opening
Power110-220V 50/60HZ 120W110-220V 50/60HZ 120W

1: Paltier precise temperature function;
2: a key automatic detection function;
3: in line with the international and ISO in the determination of the melting point of oils and fats.

The Main Technical Indicators of JHY70 & JHY90

ModelJHY70JHY90
Temperature control rangeRT-100℃4-100°
Detection methodFully automatic(compatible with Semi-automatic)Fully automatic(compatible with Semi-automatic)
Capacity per batch2pc./batch2pc./batch
Temperature resolution0.1℃0.1℃
Temperature gradients(0.1-10.0)℃/Min(0.1-10.0)℃/Min
Temperature accuracy±0.3℃±0.3℃
Repeatability0.1℃/Min时±0.1℃0.1℃/Min时±0.1℃
Camera&VideoCameraCamera&Video
Video playbackNOYES
Operator account1020
Result storage6001000
SD card capacity8G16G
DisplayTFT Touch screenTFT Touch screen
InterfaceUSB RS232 SD card EnternetUSB RS232 SD card Enternet
Opening capillary sizeI.D.1.0mm,O.D.1.4mmI.D.1.0mm,O.D.1.4mm
Power110-220V 50/60HZ 120W110-220V 50/60HZ 120W

Standard:SNT0801.5-2015、GB/T24892-2010、GBT12766-2008

Use filed

Chemical, pharmaceutical, supervision, food and drug administration, and quarantine, are widely applied in colleges and universities and other related departments. Melting point is an important feature of the material, material research is of great significance. Is the production of medicines, spices, dye, and other organic crystal substances essential equipment.

Automatic melting point meter

Other Automatic Melting Point Meters