DW04S-3C/DW04S-3E Gel Documentation System
DW series Gel Documentation system is used for gel map observation after electrophoresis running.DNA or other bio-moleculars can not be seen under natural light,but with the help of UV light and high resolution CCD,it can be realized with fluorescent stain,such as ethidium bromide.
Working with software,the electrophoreogram can be analysed and photographed by gel documentation system.Meanwhile, the impages can be zoomed in and out according to users’ requirements.
Features of DW04S-3C/DW04S-3E Gel Documentation System
- CCD with lower lux and high-resolution, easy to get dim stripes and real-time browse,whole-screen display and simple to operate:
- 6x zoom lens, easy to observe the zooming of gel.
- It is easy to observe to place the gel to the center with a center indicator.
- Intelligent control of dark box:
- The zoom, focus, aperture, UV light and white light can be controlled by panel keys.
- Auto-shut-down function for UV light when the door is opened and a controlled switch to UV light for gel cut.
- Auto-delay-shutdown function for UV light.
- Zoom lens protection, RS232/USB interface.
- Drawer-design gel platform with gel-cut protective cover, convenient to observe, operate and cut gel.
- White light conversion plate.
- Multi-layer coated filter kit effectively filter out background interference noise.
- The zoom, focus, aperture, UV light and white light can be controlled by PC.
- Normative and reliable modular-design components, easy to maintain and replace.
Parameters of DW04S-3C/DW04S-3E Gel Documentation System
| Model | DW04S-3C | DW04S-3E |
| Effective pixel | 1280×1024 | 2560×1920 |
| Pixel density | 10 bit | 10 bit |
| Pixel size | 5.4×5.4 (um) | 5.4×5.4 (um) |
| Resolution | 1.4 megapixels | 5.0 megapixels |
| Signal to noise ratio | ≥56db | ≥56db |
| Sensitivity | Can detect the double chain DNA of EB staining below 20pg. | Can detect the double chain DNA of EB staining below 20pg. |
| Camera | low illumination and high resolution digital CCD | low illumination and high resolution digital CCD |
| Zoom lens | F=1:1.2,2/3″ inch 6x zoom lens | F=1:1.2,2/3″ inch 6x zoom lens |
| Filter | 590(nm) | 590(nm) |
| UV light transmission size(W×L) | 250×200(mm) | 250×200(mm) |
| Visible light transmission size(W×L) | 250×210(mm) | 250×210(mm) |
| Transmission UV wavelength | 302(nm) | 302(nm) |
| Reflectance UV wavelength | 254,365 (nm) | 254,365 (nm) |
| Transmission UV lamp power | 302nm(8W) | 302nm(8W) |
| Reflectance UV lamp power | 254nm(11W),365nm(11W) | 254nm(11W),365nm(11W) |
| Dimention (L×W×H) | 470×405×820(mm) | 470×405×820(mm) |
| Weight | 29.0 (kg) | 29.0 (kg) |