DW-F98 Fluorescence Spectrophotometer

DW-F98 fluorescence spectrophotometer is a new generation of high-performance molecular luminescence analysis equipment. This product is designed for high performance, with high signal to noise ratio, ultra-high scanning speed, ultra-high resolution, ultra-high wavelength accuracy and a variety of accessories. This instrument easily meets the requirements in material research, drug analysis, biochemical and clinical testing, water quality control, food safety testing and other areas of qualitative and quantitative analysis and scientific research. Quantum yield accessory is available for F98 fluorescence spectrophotometer.

Main Features of DW-F98 Fluorescence Spectrophotometer

  • Horizontal slit optical design, with excellent luminous detection efficiency and high signal to noise ratio. Water Raman peak SNR better than 350: 1 (P-P) or 1500: 1 (RMS). The minimum sample volume is 0.5mL when using a standard 10mm square sample cell.
  • Wavelength scanning speed up to 60000 nm / min.
  • Bandwidth 1/2/5/10/20nm adjustable.
  • Fluorescence Quantum Yield accessory available.
  • The software offers fluorescence 3D scanning, equal-wavelength difference synchronous scanning, equal wave number difference (constant energy difference) synchronous scanning functions. (synchronous scanning function require pro version software)
  • Multi accessories available.
  • Using Hamamatsu’s high quality Xenon light source and photoelectric multiplier tube detectors and instruments to provide sufficient light intensity signal and the detection sensitivity.
  • Built-in frequency filter. Built-in optical gate, designed for unstable sample.
F98 Fluorescence Spectrophotometer
F98 Fluorescence Spectrophotometer inside

Specifications of DW-F98 Fluorescence Spectrophotometer

Product Name F98 Series Fluorescence Spectrophotometer
Picture DW-F98 Fluorescence Spectrophotometer
Excitation Source 150W xenon lamp(Hamamatsu)
Excitation Wavelength 200nm~900nm
Emission Wavelength 200nm~900nm
Excitation Slit 1nm/2nm/5nm/10nm/20nm
Emission Slit 1nm/2nm/5nm/10nm/20nm
Wavelength Accuracy ±0.4nm
Wavelength Repeatability ≤0.2nm
Signal-to-Noise Ratio S/N≥350(P-P)  S/N≥1500(RMS) S/N≥15000(RMS BG)
Limit ≤5×10-11 g/ml(Quinine Sulfate Solution)
Linearity γ≥0.995
Peak Repeatability ≤1.5%
Wavelength Scan Speed Multi-speed Level, Maximum at 60000nm/min
Minimum sample size 0.5mL (Using a standard 10mm square sample cell)
Octave filter Build in Octave filter
Photometric Quantity Range -9999 ~ 9999
Response Time 0.02/0.1/0.5/1/2/4/8 s,Auto adjust
Data Transportation USB2.0
Power 200W
Power Source AC 220V/50Hz; 110V/60Hz
Instrument Dimension 610×460×365(mm)
Weight Net Weight:21kg  Gross Weight:26kg

Accessories of DW-F98 Fluorescence Spectrophotometer

Other Fluorescence Spectrophotometer