PCR-600/PCR-800 Desktop PCR Laminar Flow Cabinet

This is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless dean environment.

Features of PCR-600/PCR-800 Desktop PCR Laminar Flow Cabinet

  1. The PCR clean bench extracts air from the laboratory, enters the operation area through a two-stage filtration system, forms a clean area, and finally discharges it into the laboratory.
  2. The system includes a positive pressure HEPA filtration system that creates an uninterrupted ISO Class 5 air clean area in the sample preparation area.
  3. The chamber can accommodate tube racks, racks, pipettes, microcentrifuges and thermal cyclers.
  4. The control system adopts intelligent microcomputer control, blue display screen, digital indication of various parameters.
  5. The work surface is made of integrated stainless steel, which is easy to clean.
  6. The front 10° inclined operation surface is more ergonomic and more comfortable to operate.
  7. The quasi-closed table top has a stepped design at the front end. When the front window is completely closed, it is more effective to prevent the introduction of external air.
  8. Interlock function of lighting and sterilization system, with spare socket design, safe and convenient to use.
  9. The box body adopts cold-rolled steel plate spraying process, and the appearance is finely sprayed.
  10. The glass door of the hanging lifting system can be opened up and down, which is convenient and flexible to operate. The sliding door can be lifted and lowered freely, and can be stopped at any position. The double-sided perspective window design has better lighting effect and wider field of vision
  11. The integrated design of the built-in HEPA high-efficiency filter, the clean airflow covers the entire working area, and the wind speed and cleanliness are better.

Technical Parameters of PCR-600/PCR-800 Desktop PCR Laminar Flow Cabinet

Model SpecPCR-600PCR-800
CleanlinessClass 100@≥0.5μM (US Federal 209E)
Number of colonies≤0.5/dish hour (Φ90mm culture dish)
Average wind speed0.25~0.45m/s
Airflow directionVertical airflow
Noise≤62dB(A)
Illumination≥300Lx
PowerAC single phase 220V/50Hz
Work area sizeW1×D1×H1580×500×450780×500×450
Overall dimensionW×D×H600×550×840800×550×840
HEPA filter size and quantity515×405×50×①715×405×50×①
LED/UV lamp specifications and quantity5W×①/10W×①5W×①/10W×①

Desktop PCR Laminar Flow Cabinet Display