PCR-1S/2S PCR Laminar Flow Cabinet
The PCR Cabinet extracts air from the laboratory, enters the operation area through a two-stage filtration system, forms a clean area, and finally discharges it into the laboratory, provides a sterile workplace to protect samples from airborne contamination.
The PCR Cabinet is widely used in medicine and health, biopharmaceutical, food, medical science experiments, aseptic room experiments and other laboratories.
Features of PCR-1S/2S Laminar Flow Cabinet
- The system includes a positive pressure HEPA filtration system, which can form an uninterrupted ISO Class 5 air clean area in the sample preparation area.
- The chamber can accommodate tube racks, racks, pipettes, microcentrifuges and thermal cyclers.
- The control system adopts intelligent microcomputer control, blue display screen, and digital indication of various parameter values.
- The work surface is made of integrated stainless steel and easy to clean.
- The 10° inclined operation surface at the front is more ergonomic and more comfortable to operate.
- The quasi-closed table has a stepped design at the front end. When the front window is fully closed, it can more effectively prevent external gas from entering.
- The lighting and sterilization system interlocking function, with a spare socket design, is safe and convenient to use.
- The box body adopts cold-rolled steel plate spraying process, and the appearance is delicate.
- The suspended lifting system glass door opens up and down, is easy to operate, and can be lifted and lowered freely, and can stay at any position. The double-sided perspective window design provides better lighting and a wider field of vision.
- The HEPA filter is integrated, and the clean airflow covers the entire working area, with better wind speed and cleanliness.
Structure of PCR-1S/2S Laminar Flow Cabinet

Details of PCR-1S/2S Laminar Flow Cabinet

HEPA Filter ensures a clean environment in the work area.

Digital display control panel, three-speed adjustable for fast, medium and slow, more humanized design.

Equipped with high-brightness fluorescent lamps, safety interlocking of lighting and sterilization systems.

The motor has strong power,low heat generation,low noise, energy-saving and power-saving.

The working area is equipped with sockets(four options are available)to facilitate the experiment plug-in needs.

The base is equipped with universal wheels to facilitate the movement of the clean bench.
Specifications of PCR-1S/2S Laminar Flow Cabinet
| ModelSpec. | PCR-1S | PCR-2S |
| Cleanliness | Class 100 @ ≥ 0.5 μM (U.S. Federal 209E) | |
| Number of colony | ≤0.5/dish·hour (Φ90mm culture dish) | |
| Average wind speed | 0.25~0.45m/s | |
| Noise | ≤62dB(A) | |
| Vibration half peak value | ≤5μM(x、y、z) | |
| Illuminance | ≥300Lx | |
| Voltage | AC single phase 220V/50Hz | |
| Max power consumption | 100W | 500W |
| Weight | 80kg | 110kg |
| Work area size(W*D*H)(mm) | 700×510×580 | 1150×510×580 |
| Overall dimension(W*D*H)(mm) | 860×590×1620 | 1310×590×1620 |
| Application | For one person useOne operation side | For two persons useOne operation side |
| HPEA specifications | 685×455×50×① | 1135×455×50×① |
| LED/UV lamp specifications | 12W×①/20W×① | 12W×①/30W×① |
PCR-1S Display