IP/IPP Adjustable Autoclavable Pipette
- Complete specifications: The volume range changes from 0.1ul to 10000ul, which can ultimately achieve transfering from ultra-micro to conventional ranges in the laboratory.
- Special materials: special engineering plastics, very suitable for research-type pipetting work.
- Professional design: American professional design, beautiful design with comfortable colors, and applied ergonomic principles.
- Inner core metal: the inner core adopts special aviation metal materials, to ensure maximum durability, accuracy and stability, and to avoid easy deformation of the plastic inner core.
- Almighty lock: set and lock at any time to prevent accidental change of the set range, which effectively changed the traditional pipette did not lock and simple locking function. It can also be used as a fixed pipette, truly realizing one machine with multiple functions.
- Special shell: the shell is sprayed with special materials, which can effectively prevent heat transfer through the handle, so as to fundamentally ensure the accuracy.
- Lightweight: the entire weight of IP/IPP is only 100g, and the spring force is only 2/3 of that of conventional pipettes, which effectively reduces the operator’s intensity and prevents occupational diseases.
Applications of IP/IPP Adjustable Autoclavable Pipette
The IP / IPP adjustable autoclavable pipette is widely used in clinical diagnostic laboratories, biotechnology laboratories, pharmacy and chemistry laboratories, environmental laboratories, food laboratories, electromechanical laboratories, etc.
| Model No. | Volume (µL) | Increment (µL) | Rel. (%) | Abs (µL) | Rel. CV (%) | Abs SD (µL) |
| IP2 IPP2 | 0.2 | 0.002 | 8 | 0.016 | 6 | 0.012 |
| 1 | 2.7 | 0.027 | 1.3 | 0.013 | ||
| 2 | 1.5 | 0.03 | 0.7 | 0.014 | ||
| IP10 IPP10 | 1 | 0.02 | 2.5 | 0.025 | 1.2 | 0.012 |
| 5 | 1.5 | 0.075 | 1 | 0.05 | ||
| 10 | 1 | 0.1 | 0.8 | 0.08 | ||
| IP20 IPP20 | 2 | 0.02 | 1.5 | 0.03 | 2 | 0.04 |
| 10 | 1.5 | 0.15 | 0.5 | 0.05 | ||
| 20 | 0.9 | 0.18 | 0.3 | 0.06 | ||
| IP50 IPP50 | 5 | 0.02 | 1.5 | 0.15 | 2 | 0.04 |
| 25 | 1.5 | 0.15 | 0.5 | 0.05 | ||
| 50 | 0.6 | 0.12 | 0.3 | 0.06 | ||
| IP100 IPP100 | 10 | 0.2 | 1.5 | 0.15 | 1 | 0.1 |
| 50 | 0.8 | 0.4 | 0.24 | 0.12 | ||
| 100 | 0.8 | 0.8 | 0.15 | 0.15 | ||
| IP200 IPP200 | 20 | 0.2 | 1.5 | 0.3 | 1 | 0.2 |
| 100 | 0.8 | 0.8 | 0.25 | 0.25 | ||
| 200 | 0.6 | 1.2 | 0.15 | 0.3 | ||
| IP300 IPP300 | 30 | 0.2 | 1.5 | 0.45 | 1 | 0.2 |
| 150 | 0.8 | 0.8 | 0.25 | 0.25 | ||
| 300 | 0.6 | 1.2 | 0.15 | 0.3 | ||
| IP1000 IPP1000 | 100 | 2 | 3 | 3 | 0.6 | 0.6 |
| 500 | 0.8 | 4 | 0.2 | 1 | ||
| 1000 | 0.6 | 6 | 0.15 | 1.5 | ||
| IP5000 IPP5000 | 500 | 5 | 2.4 | 12 | 0.6 | 3 |
| 2500 | 0.6 | 15 | 0.2 | 5 | ||
| 5000 | 0.6 | 18 | 0.16 | 8 | ||
| IP10000 IPP10000 | 1000 | 20 | 3 | 3 | 0.6 | 0.6 |
| 5000 | 0.8 | 4 | 0.2 | 1 | ||
| 10000 | 0.8 | 8 | 0.15 | 1.5 |


.jpg)
.jpg)
.jpg)
.jpg)
.jpg)
.jpg)