| Model No. | Volume (µL) | Increment (µL) | Rel. % | Abs (µL) | Rel. CV% | Abs SD (µL) |
| EP2 | 0.2 | 0.002 | 12.0 | 0.024 | 6.00 | 0.012 |
| 1 | 2.7 | 0.027 | 1.30 | 0.013 | ||
| 2 | 1.5 | 0.030 | 0.70 | 0.014 | ||
| EP10 | 1 | 0.02 | 2.5 | 0.025 | 1.20 | 0.012 |
| 5 | 1.5 | 0.075 | 0.60 | 0.030 | ||
| 10 | 1.0 | 0.100 | 0.40 | 0.040 | ||
| EP20 | 2 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
| 10 | 1.5 | 0.15 | 0.50 | 0.050 | ||
| 20 | 1.0 | 0.20 | 0.30 | 0.060 | ||
| EP50 | 5 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
| 25 | 1.5 | 0.15 | 0.50 | 0.050 | ||
| 50 | 1.0 | 0.20 | 0.30 | 0.060 | ||
| EP100 | 10 | 0.2 | 3.5 | 0.35 | 1.00 | 0.10 |
| 50 | 0.8 | 0.40 | 0.24 | 0.120 | ||
| 100 | 0.8 | 0.80 | 0.15 | 0.150 | ||
| EP200 | 20 | 0.2 | 2.5 | 0.5 | 1.00 | 0.200 |
| 100 | 0.8 | 0.8 | 0.25 | 0.250 | ||
| 200 | 0.8 | 1.60 | 0.15 | 0.300 | ||
| EP300 | 30 | 0.2 | 2.5 | 0.5 | 1.00 | 0.02 |
| 150 | 0.8 | 0.8 | 0.25 | 0.25 | ||
| 300 | 0.8 | 1.60 | 0.15 | 0.30 | ||
| EP1000 | 100 | 2.0 | 3.0 | 3.0 | 0.60 | 0.600 |
| 500 | 0.8 | 4.0 | 0.20 | 1.000 | ||
| 1000 | 0.8 | 8.0 | 0.15 | 1.5 | ||
| EP5000 | 500 | 5.0 | 2.4 | 12.0 | 0.60 | 3.0 |
| 2500 | 0.6 | 15.0 | 0.20 | 5.0 | ||
| 5000 | 0.6 | 18.0 | 0.16 | 8.0 |
Features of EPP Adjustable Autoclavable Pipette
- Fully autoclavable. ( 121℃ for 20 minutes )
- Enhanced UV resistance.
- Easy digital volume setting.
- Easy and convenient single hand locking lever.
- Eight sizes to cover a wide volume range. ( 0.1μL – 10mL )
- PTFE ( Fluorine resin ) is used in the airtight chamber of the instrument, so the instrument keeps its air tightness and precise reproducibility for long hours.
- Filtered Nozzles are used for volume models larger than 1000μL.
- Tip ejector allows tip ejections without touching the tip.
- Tip ejector is made of plastic to avoid damaging glass tubes.
| Model No. | Volume (L) | Increment (L) | Rel.% | -% Abs L | Rel.CV%・CV% | Abs SD L |
| EPP2 | 0.2 | 0.002 | 12.0 | 0.024 | 6.00 | 0.012 |
| 1 | 2.7 | 0.027 | 1.30 | 0.013 | ||
| 2 | 1.5 | 0.030 | 0.70 | 0.014 | ||
| EPP10 | 1 | 0.02 | 2.5 | 0.025 | 1.20 | 0.012 |
| 5 | 1.5 | 0.075 | 0.60 | 0.030 | ||
| 10 | 1.0 | 0.100 | 0.40 | 0.040 | ||
| EPP20 | 2 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
| 10 | 1.5 | 0.15 | 0.50 | 0.050 | ||
| 20 | 1.0 | 0.20 | 0.30 | 0.060 | ||
| EPP50 | 5 | 0.02 | 7.5 | 0.15 | 2.00 | 0.040 |
| 25 | 1.5 | 0.15 | 0.50 | 0.050 | ||
| 50 | 1.0 | 0.20 | 0.30 | 0.060 | ||
| EPP100 | 10 | 0.2 | 3.5 | 0.35 | 1.00 | 0.10 |
| 50 | 0.8 | 0.40 | 0.24 | 0.120 | ||
| 100 | 0.8 | 0.80 | 0.15 | 0.150 | ||
| EPP200 | 20 | 0.2 | 2.5 | 0.5 | 1.00 | 0.200 |
| 100 | 0.8 | 0.8 | 0.25 | 0.250 | ||
| 200 | 0.8 | 1.60 | 0.15 | 0.300 | ||
| EPP300 | 30 | 0.2 | 2.5 | 0.5 | 1.00 | 0.02 |
| 150 | 0.8 | 0.8 | 0.25 | 0.25 | ||
| 300 | 0.8 | 1.60 | 0.15 | 0.30 | ||
| EPP000 | 100 | 2.0 | 3.0 | 3.0 | 0.60 | 0.600 |
| 500 | 0.8 | 4.0 | 0.20 | 1.000 | ||
| 1000 | 0.8 | 8.0 | 0.15 | 1.5 | ||
| EPP5000 | 500 | 2.0 | 2.4 | 12.0 | 0.60 | 3.0 |
| 2500 | 0.6 | 15.0 | 0.20 | 5.0 | ||
| 5000 | 0.6 | 18.0 | 0.16 | 8.0 | ||
| EPP10000 | 1000 | 2.0 | 3.0 | 3.0 | 0.60 | 0.6 |
| 5000 | 0.8 | 4.0 | 0.20 | 1.0 | ||
| 10000 | 0.8 | 8.0 | 0.15 | 1.5 |