Features
- The product shell is made of high-quality steel plates and is electrostatically sprayed on the surface. The design is elegant. The working chamber is processed and made of high-quality stainless steel, which is corrosion-resistant and resistant to aging. The inner walls have a rounded transition.
- It adopts an intelligent microcomputer liquid crystal display control system, featuring functions such as timing, alarm, and over-temperature protection.
- The brand compressor uses non-chlorofluorocarbon (CFC-free) environmentally friendly refrigeration technology. The gentle air circulation ensures uniform temperature inside the box.
- The balanced control of cooling and heating ensures a small temperature fluctuation and more precise temperature control.
- The tempered glass observation window makes it easy to observe the changes of items inside the box. The magnetic adhesive strips provide a secure seal, facilitating opening and maintaining excellent sealing performance.
- Using ultrasonic humidification, the humidity control is stable. The humidity fluctuation range is ±5 – 8% RH. It also has the function of automatically shutting off when there is insufficient water.
- It is equipped with multiple safety measures such as compressor overheating protection and instrument failure protection to ensure the safety of the experiment.
- It can be equipped with functions such as printer, 485 interface, USB storage, and SMS alarm.
Upgrade content: (9-point test temperature)
- Inner liner thickness upgrade: The original thickness was 0.8mm, and the upgraded thickness is 1.0mm.
- Increased automatic defrosting capability, improving the equipment’s operational efficiency, reducing energy consumption and extending service life.
- Fan upgrade, from capacitor fan to axial brushless fan, ensuring uniform temperature distribution inside the box.
Specifications
| Model | DWS-80BF | DWS-150BF | DWS-250BF | DWS-350BF | DWS-460BF |
| Volume | 80L | 150L | 250L | 350L | 460L |
| Rated power supply | 220V 50HZ | ||||
| Temperature control range | 5℃-65℃ | ||||
| Temperature resolution | 0.1 | ||||
| Temperature fluctuation degree | ±1℃(37℃) | ||||
| Temperature distribution accuracy | ±1.5℃ (set temperature 37℃, ambient temperature 25℃) | ||||
| Humidity range | 40%-95%RH | ||||
| Inner container material | 201 stainless steel inner liner | ||||
| Outer shell material | Galvanized sheet (electrostatic spraying) | ||||
| Insulation layer | Polyurethane | ||||
| Heater | Stainless steel heating tube | ||||
| Compressor | Air-cooled fully enclosed compressor | ||||
| Refrigerant | R134a | ||||
| Defrosting function | Intelligent control for automatic defrosting | ||||
| Temperature control | Single-stage liquid crystal intelligent PTD controller | ||||
| Timer function | 0-9999min | ||||
| Operation mode | Fixed-value operation, timed operation, automatic stop | ||||
| Test hole | Come with a standard one | ||||
| Sensor | PT100 | ||||
| Power | 600W | 800W | 1000W | 1200W | 1400W |
| Inner liner dimensions (mm) (D×W×H) | 400×400×500 | 400×500×750 | 500×550×910 | 600×600×1000 | 650×650×1100 |
| Overall dimensions (mm) (D×W×H) | 610×550×1065 | 605×655×1355 | 700×705×1550 | 780×750×1605 | 845×805×1710 |
| Packaging dimensions (mm) (D×W×H) | 690×620×1150 | 770×735×1520 | 820×800×1660 | 870×860×1800 | 990×1040×1970 |
| Standard/Maximum number of partitions | 2/4 | 2/7 | 2/9 | 2/10 | 2/11 |
| Partition spacing | 75mm | 80mm | 80mm | 83mm | 80mm |
| Partition load-bearing capacity | 20kg | ||||
| Additional functions | Ultrasonic humidification | ||||
| Optional functions | Printer, USB interface, 485 interface, SMS alarm module | ||||