DW-TCS10 Thermo Shaker
DW-TCS10 thermo shaker is a temperature controlled shaker, which is useful for a variety of molecular biology applications. Speed, time and temperature settings are continuously visible on the LCD, simultaneously showing both actual and selected values. Integral over-temperature control ensures long time, safety and sample integrity.
Features of DW-TCS10 Thermo Shaker
- LCD display. It is easy to setup and use.
- Reliable design with inner extra temperature protection.
- Each device is equipped with lifter that is easy to replace different blocks.
- Digital accuracy and convenience.
- Precision wells for uniform thermal transfer.
- Assorted blocks for a wide variety of tube sizes.
- Brushless DC Motor: noiseless long service life maintenance-free.
- Conform to CE safety standard.
- Accurately control and display time, temperature and speed.
Applications of DW-TCS10 Thermo Shaker
- Maintaining 14°C for ligation reactions.
- Maintaining 17°C for storing oocytes.
- Storing samples at ice bucket temperatures.
- Storing enzymes or DNA libraries at your work station.
- Transporting samples from the field at exactly the right temperature.
- Heating samples in the field.
- Enzyme reactions and deactivations.
- PCR sample preparation.
Parameters of DW-TCS10 Thermo Shaker
| Model | DW-TCS10 |
| Temp setting range | 0℃~100℃ |
| Temp control range | RT.-20℃~100℃ |
| Time range | 1min ~ 99h59min/∞ |
| Temp accuracy | ≤±0.3℃* |
| Display accuracy | 0.1℃ |
| Temp uniformity | ≤±0.3℃* |
| Speed range | 200~1500rpm |
| Orbit | 3mm |
| Heating time | ≤12min(from 25℃ to 100℃)* |
| Cooling time1 | ≤10min(from 100℃ to 25℃)* |
| Cooling time2 | ≤20min(from RT. to RT.-20℃)* |
| Multi point running | Yes(Max 5points) |
| Multi cycle | Yes(Max 99times) |
| Auto heating | Yes |
| Auto running | Yes |
| Auto resume to run | Yes |
| Storage at 4℃ | Yes |
| Power supply | 150W |
| Voltage | AC110V~220V/50-60Hz |
| Fuse | 250V 3A Ф5×20 |
| Dimension(mm) | 260x195x150 |
| Weight(kg) | 7.5 |
Optional Blocks
| Type | Capacity | Temp range | Max Speed |
| MD30 | 96×0.2ml | 0℃~100℃ | 1500rpm |
| MD31 | 54×0.5ml | 0℃~100℃ | 1500rpm |
| MD32 | 35×1.5ml | 0℃~100℃ | 1500rpm |
| MD33 | 35×2.0ml | 0℃~100℃ | 1500rpm |
| MD34 | 20×1.5ml+15×0.5ml | 0℃~100℃ | 1500rpm |
| MD35 | 96×0.2ml | 0℃~100℃ | 1500rpm |
| MD36 | 24x5ml | 0℃~100℃ | 1000rpm |
| MD37 | 15x10ml | 0℃~100℃ | 1000rpm |
| MD38 | 12x15ml | 0℃~100℃ | 800rpm |
| MD39 | 6x50ml(round-shape bottom) | 0℃~100℃ | 800rpm |
| MD39-SA | 6x50ml(cone-shape bottom) | 0℃~100℃ | 800rpm |










