DW-E Series Universal Power Supply

DW-E series universal power supply include 10 models, the maximum output voltage varies from 200V to 10000V, can widely cover most electrophoresis experiments, DRAWELL can provide different types of power supplies for experiments with different uses.

DW-E series universal power supply is based on the DW-C series universal power supply on the optimization of control program, expansion the product function, which simplifies the operation, and greatly improve the performance of the electrophoresis power supply.

Features of DW-E Series Universal Power Supply

  1. Molding shell, touch keys, dual-core microprocessor, intelligent control.
  2. 0-9 digital button, easy and convenient to operate.
  3. Indicate the preset value and the actual output value at the same time.
  4. Can store 100 electrophoresis methods.
  5. Automatic memory function.
  6. Step-by-step control function (editable 10 groups, each group of up to 10 program automatic connection operations).
  7. Pause control function (including real-time tuning)
  8. Standard, timing, V-hr, step-by-step operation function.
  9. Constant voltage, constant current, constant power, misoperation, fault and other warning functions.
  10. Automatic detection of no-load, overload, short circuit, rapid resistance change, ground leak, and system overheating.
Stackable Chassis Design
Stackable Chassis Design
Low noiseStrong radiator Fan
Low Noise, Strong Radiator Fan
Embedded Power Jacks
Embedded Power Jacks

Parameters of DW-E Series Universal Power Supply

ModelDW300EDW600EDW1000E
Voltage range5~300 V10~600 V30~1000 V
Current range1~400 mA1~500 mA1~500 mA
Power range1~120 W1~300 W1~300 W
Type of controlConstant V,Constant l and Constant PConstant V,Constant l and Constant PConstant V,Constant l and Constant P
Display typeLCD screen with backlightLCD screen with backlightLCD screen with backlight
Output jackFour setsFour setsFour sets
Storage functionStore 100 methodsStore 100 methodsStore 100 methods
Programming methodCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 steps
Timing function1min-99h59min1min-99h59min1min-99h59min
V-hr functionYes,1~99999 V-hrYes,1~99999 V-hrYes,1~99999 V-hr
Pause control functionYesYesYes
Power recovery functionOptionalOptionalOptional
Automatic memory functionYesYesYes
Automatic shutdown functionYesYesYes
Intelligent prompt functionsYesYesYes
Non-proliferation field functionOptionalOptionalOptional
Temperature detection functionNoNoNo
Safety performanceYesYesYes
Molding machine casingYesYesNo
Dimension (LxWxH)280×237×118(mm)280×237×118(mm)263×275×125(mm)
Weight3.2 kg3.2 kg4.6kg
ModelDW-600HEDW-300HEDW-200E
Voltage range5~600 V0~300V5~200 V
Current range1~1000 mA~1500mA~2000 mA
Power range~300 W~450  W~200 W
Type of controlConstant V, Constant IConstant V, Constant lConstant V, Constant and Constant P
Display typeLCD screen with backlightCD screen with backlightLCD screen with backlight
Output jackFour setsFour setsFour sets
Storage functionStore 100 methodsStore 100 methodsStore 100 methods
Programming methodCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 steps
Timing functionmin-99h59min1min-99h59min1min-99h59min
V-hr functionYes,1~99999 V-hrYes,1~99999 V-hrYes,1~99999 V-hr
Pause control functionYesYesYes
Power recovery functionOptionalOptionalOptional
Automatic memory functionYesYesYes
Automatic shutdown functionYesYesYes
Intelligent prompt functionsYesYesYes
Non-proliferation field functionOptionalOptionalOptional
Temperature detection functionNoNoNo
Safety performanceYesYesYes
Molding machine casingNoYesYes
Dimension (LxWxH)263×275×125(mm)280×237×118(mm)280×237×118(mm)
Weight4.4 kg3.2 kg3.2 kg
ModelDW-1600EDW-3000EDW-5000EDW-10000E
Voltage range10~1600V20~3000V20~5000V20~10000 V
Current range1~200mA1~400 mA~200 mA~3500μA
Power range1~320W1~400 W1~100 W1~35 W
Type of controlConstant V,Constant and Constant Pand Constant PConstant V,Constant lConstant V,Constant l and Constant P
Display typeCD screen with backlightLCD screen with backlightCD screen with backlightCD screen with backlight
Output jackFour setsFour setsTwo setsTwo sets
Storage functionStore 100 methodsStore 100 methodsStore 100 methodsstore 100 methods
Programming methodCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 stepsCan store 10 methods each up to 10 stepseach up to 10 steps
Timing function1min-99h59min1min-99h59min1min-99h59min1min-99h59min
V-hr functionYes,1~99999 V-hrYes,1~99999 V-hYes,1~99999 V-hrYes,1~99999 V-br
Pause control functionYesYesYesYes
Power recovery functionOptionalOptionalOptionalOptional
Automatic memory functionYesYesYesYes
Automatic shutdown functionYesYesYesYes
Intelligent prompt functionsYesYesYesYes
Non-proliferation field functionOptionalOptionalOptionalOptional
Temperature detection functionNoNoYesYes
Safety performanceYesYesYesYes
Molding machine casingNoNoNoNo
Dimension (LxWxH)263×275×125(mm)263×275×125(mm)368×255×133(mm)370×255×133 (mm)
Weight4.4 kg4.8 kg10.6kg12.0 kg

DW-E Series Universal Power Supply Display

Other Electrophoresis Tank