DPX-C Series Touch Screen Biochemical Incubator

Model: DPX-50C DPX-80C DPX-150C DPX-250C DPX-350C DPX-460C

Features of DPX-C Touch-screen Biochemical Incubator

  1. The box body shell is made of high-quality galvanized sheet, and its surface is treated by electrostatic spraying technology. The design is elegant and practical, with excellent corrosion resistance and durability.
  2. The inner liner is made of high-quality 304 stainless steel. The four corners have a semi-circular arc transition, which is convenient for cleaning and maintenance. The height of the shelves can be adjusted freely.
  3. Double-door structure design: Inner doors are equipped with tempered glass, while the outer doors are sealed with magnetic rubber strips. The working chamber is equipped with lighting, facilitating observation.
  4. Touch control instrument: Supports two operation modes – fixed value and program. It can set 5*100 segments of program control.
  5. Data recording function: Standard equipped with USB interface, capable of exporting historical data in both CSV and PDF formats, and allowing for detailed numerical historical curve queries;
  6. It adopts a variable-frequency compressor, featuring energy-saving, low noise, and no frosting problems.
  7. Install a temperature alarm system with automatic temperature limit function and automatic power-off feature to ensure the safety of the experiment.
  8. The excellent insulation design ensures good sealing performance and prevents temperature loss.
DPX 50C DPX 80C DPX 150C DPX 250C DPX 350C DPX 460C 4

Specifications of DPX-C Touch-screen Biochemical Incubator

ModelDPX-50CDPX-80CDPX-150CDPX-250CDPX-350CDPX-460C
Capacity50L80L150L250L350L460L
Power supply220V 50Hz
Temperature control range5℃-65℃
Temperature distribution accuracy±1℃
Temperature resolution0.1℃
Temperature fluctuation degreeHigh temperature ± 0.5℃, low temperature ± 1℃
Inner liner material 304 stainless steel inner liner
Shell materialGalvanized sheet (electrostatic spraying)
Insulation layer Polyurethane
CompressorVariable-frequency compressor
RefrigerantR134a
HeaterStainless steel heating tube
Defrosting functionIntelligent control for automatic defrosting
Temperature controlHigh-definition LCD touch screen
Timer functionmax: 999h59min
Operation modeCustomized operation mode, program operation mode
Test hole Standard configuration – one
SensorPT100
Power500w600w800w1000w1200w1400w
Inner liner dimensions (mm)350×350×400400×400×500400×500×750500×550×910600×600×1000650×650×1100
Overall dimensions (mm) 580×460×900610×560×1070600×660×1400700×720×1590790×760×1640850×805×1630
Packaging dimensions (mm) 615×510×980690×620×1150770×735×1520820×800×1660870×860×1800990×1040×1970
Standard/Maximum number of partitions2/42/42/72/92/102/11
Partition spacing75mm75mm80mm80mm83mm80mm
Partition load-bearing capacity 20kg
Additional functionsLighting fixture
Optional functionsWaterproof socket, SMS alarm, temperature monitoring, printer