DMJ-BF Precision Mold Culture Chamber

Features of DMJ-BF Precision Mold Culture Chamber

  • The box body shell is made of high-quality galvanized sheet, and its surface is treated by electrostatic spraying technology. The design is elegant and practical, with excellent corrosion resistance and durability.
  • The inner liner is made of high-quality stainless steel. The four corners smoothly transition into semi-circular shapes, facilitating cleaning. The height of the shelves can be adjusted freely.
  • Single-door structure design: Tempered glass observation window, sealed with magnetic rubber strips, and an ultraviolet sterilization lamp is installed in the working chamber.
  • Microcomputer control system, large-screen LCD display, touch-type operation buttons, easy to operate;
  • Using high-end compressors and circulating fans, it achieves low energy consumption and energy savings.
  • A temperature alarm system is provided, with automatic temperature limit and automatic power cut-off to ensure the safety of the experiment. Excellent insulation design is adopted to ensure good sealing performance and prevent temperature loss.

Upgrade content: (9-point test temperature)

  1. Inner liner thickness upgrade: The original thickness was 0.8mm, and the upgraded thickness is 1.0mm.
  2. Increased automatic defrosting capability, improving the operational efficiency of the equipment, reducing energy consumption and extending the service life.
  3. Fan upgrade, from capacitor fan to axial brushless fan, ensuring uniform temperature distribution in the box.

Specifications of DMJ-BF Precision Mold Culture Chamber

ModelDMJ-80BFDMJ-150BFDMJ-250BFDMJ-350BFDMJ-460BF
Capacity80L150L250L350L460L
Power supply220V 50Hz
Temperature control range5℃-65℃
Temperature distribution accuracy±1.5℃ (set temperature 37℃, ambient temperature 25℃)
Temperature resolution0.1℃
Temperature fluctuation degreeHigh temperature ±0.5℃, low temperature ±1℃
Inner liner material201 stainless steel inner liner
Shell material Galvanized sheet (electrostatic spraying)
Insulation layerPolyurethane
CompressorAir-cooled hermetic compressor
RefrigerantR134a
HeaterStainless steel heating tube
Defrosting functionIntelligent control for automatic defrosting
Temperature controlSingle-stage liquid crystal intelligent PID controller
Timer function0-9999min
Operation modeFixed-value operation, timed operation, automatic stop
Test hole Standard configuration – one
SensorPT100
Power600w800w1000w1200w1400w
Inner liner dimensions (mm) (Depth x Width x Height)400×400×500400×500×750 500×550×910 600×600×1000 650×650×1100
Overall dimensions (mm) (Depth x Width x Height)610×560×1070 600×660×1400 700×720×1590 790×760×1640 850 ×805×1630
Packaging dimensions (mm) (Depth x Width x Height)690×620×1150 770×735×1520 820×800×1660 870×860×1800 990× 1040×1970
Standard/Maximum number of partitions2/42/72/92/102/11
Partition spacing75mm80mm80mm83mm80mm
Partition load-bearing capacity20kg
Additional functionsUltraviolet lamp
Optional functionsWaterproof socket