DLCM-B Partition Single-sided Lighting Illumination Incubator

Model: DLCM-80B DLCM-150B DLCM-250B DLCM-350B DLCM-460B Single-Sided

Features of DLCM-B Partition Single-sided Lighting Illumination Incubator

  • The product shell is made of high-quality steel plates, with surface electrostatic spraying. The design is elegant. The working chamber is processed from high-quality stainless steel, which is corrosion-resistant and resistant to aging. The inner walls have a rounded transition and a built-in tempered glass door.
  • Using LED full-spectrum lighting is closer to natural light. The light intensity can be adjusted, and the lighting is stronger and more uniform.
  • Intelligent microcomputer control system, with precise and reliable temperature control;
  • Brand compressor uses non-chlorofluorocarbon environmentally friendly refrigeration technology. The gentle air circulation ensures uniform temperature inside the box.
  • It is equipped with multiple safety measures such as compressor overheating protection and instrument failure protection to ensure the safety of the experiment.
  • Programmable control mode, with 30 levels of illumination and temperature settings, and automatic adjustment and conversion. It can automatically simulate changes such as day and night, different temperatures, and different illumination levels.
  • It can be equipped with functions such as printer, 485 interface, USB storage, and SMS alarm.

Specifications of DLCM-B Partition Single-sided Lighting Illumination Incubator

ModelDLCM-80BDLCM-150BDLCM-250BDLCM-350BDLCM-460B
Volume80L150L250L350L460L
Rated power supply220V50HZ
Temperature control rangeWith light: 10℃ – 65℃; Without light: 5℃ – 65℃
Temperature resolution0.1℃
Temperature fluctuation degree±1℃
Light intensity0-10000LX
Light sourceSingle-sided lighting, door panel light source, LED full-spectrum cold light source
Inner container material201 stainless steel inner liner
Shell materialGalvanized sheet (electrostatic coating)
Insulation layerPolyurethane
HeaterStainless steel heating tube
CompressorAir-cooled fully enclosed compressor
RefrigerantR134a
Defrosting functionIntelligent control for automatic defrosting
Temperature controlProgrammable instrument
Timer function0-9999min
Operation modeFixed-value operation mode, program-controlled operation mode
Test holeCome with one included.
SensorPT100
Power600W800W1000W1200W1400W
Inner liner dimensions (mm)400×400×500400×500×750500×550×910600×600×1000650×650×1100
Dimensions (mm)605×555×1060600×650×1350700×705×1550780×750×1610845×805×1715
Packaging dimensions (mm)690×620×1150770×735×1520820×800×1660870×860×1800990×1040×1970
Standard/Maximum Spacer2/42/72/92/102/11
Separator spacing75mm80mm80mm83mm80mm
Supporting plate20kg
Optional functionsPrinter, USB interface, 485 interface, SMS alarm module