What is CGF?
CGF (Concentrated Growth Factor) is extracted from autologous blood by our specialized variable speed centrifuge DL4-M. The concentration of growth factor is four times higher than that of normal blood active substances and it contains CD34 positive cells and white blood cells with high activity. CD34 positive cells are important Cells for promoting the reconstruction of the micro-circulatory system and collagen regeneration. In the mesoderm, filling and wound repair, micro-capillary and micro-lymphatic systems can be quickly reconstructed in the treatment.
Features of DL-4M CGF
- 3 different running speeds/ RCF, 6 Kinds of Automatic Switching of Acceleration and Deceleration.
- Self-ventilated rotor system, compressor temperature control, and keep low temperature (15℃) working environment.
- Customize made for UV sterilize Light
- All parts of the rotor can be High Temperature and High-Pressure Sterilization.
- Can make PRP PRF CGF blood active substance.
- A swing Rotor is more effective for CGF extraction.



Technical parameters of DL-4M CGF
|
Model |
DL-4M |
|||||
|
NO.1 Swing Rotor |
8*10ml |
4000r/min |
3250xg |
|||
|
Program |
No.1 |
No.2 |
No.3 |
No.4 |
||
|
PRP |
PRF |
CGF |
adjustable |
|||
|
Motor |
Microprocessor &Brushless DC Motor |
|||||
|
Temperature Range |
-20℃~+40℃ |
|||||
|
Timer Range |
0~99min |
|||||
|
Noise |
≤50dB(A) |
|||||
|
Power Supply |
AC220V&110V50Hz 2A |
|||||
|
Dimension |
540*340*312mm(L*W*H) |
|||||
|
Weight |
40kg |
|||||
CGF application
1. Move skin wrinkles, Improve skin dryness, relaxation, dullness, spots, pore size and other phenomena.
2. Skin anti-aging
3. Promote tissue regeneration, Repair of wounds and scars
4. Reconstruction of skin barrier and repair of tissue
5. Lipid transplantation partners to improve the survival rate of fat transplantation
6. Scalp management
7. Treatment of mesodermal and osteoarthritis
CGF Therapy advantages
- CGF from autologous blood, no rejection reaction
- No Chemical additives, it’s safer
- With Various concentrated growth factors, a good effect
- The CD34 positive white cells promote the micro-circulatory system and collagen regeneration
- Multiple clinical uses – liquid/gelatinous without embolism risk
Compare 3 generations of blood-active substance PRP PRF CGF
|
Name |
Separate results |
Condition |
construction |
Molecular Structure |
|
PRP (Platelet Rich Plasma) |
PPP+PRP+RBC |
Anticoagulant |
Liquid |
Compact Tetramolecular structure |
|
PRF (Platelet Rich Fibrin) |
PPP+PRF+RBC |
No |
Gel Membrane |
3-dimension loose structure |
|
CGF (Concentrated Growth Factor) |
PPP+CFG+PRP+CD34++RBC |
No |
Liquid Gel Membrane Half-Gel |
3-dimension looser structure |