DGL-B 201 stainless steel inner liner
DGL-C 304 stainless steel inner liner
Features of DGL-B/C Vertical Electric Heating Forced Air Drying Oven
- The product casing is made of high-quality galvanized sheet and is processed into shape. The surface is treated with electrostatic spraying technology, which is corrosion-resistant and durable.
- The inner liner of the box is made of high-quality stainless steel and is processed by machine. The four corners are rounded, which is convenient for cleaning.
- The super-large ergonomic design of double-layer tempered glass observation window makes it convenient to observe the experimental process inside the box.
- The use of a new type of synthetic silicone sealant strip results in an attractive appearance and enables long-term operation at high temperatures, with an extended service life.
- Unique hot air circulation system: Utilizing low-noise self-cooling fans, this design ensures a longer lifespan for the fans and more uniform temperature inside the box.
- DGL-Csries standard feature includes wind speed adjustment function. Users can adjust the wind speed according to their experimental needs.Furthermore,DGL-9045C and DGL-9072C can set the automatic wind speed.
- Intelligent digital PID/liquid crystal temperature control instrument: Equipped with functions such as timing, over-temperature alarm, temperature deviation correction, and temperature self-tuning.
- Furthermore, in DGL-9125B,DGL-9210B, DGL-9045C and DGL-9072C, the built-in partition can be adjusted in height to meet the drying and disinfection requirements of different samples.
Specifications of DGL-B/C Vertical Electric Heating Forced Air Drying Oven
| Model | DGL-9045B/C | DGL-9072B/C | DGL-9125B/C | DGL-9210B/C |
| Volume | 45L | 72L | 125L | 210L |
| Rated power supply | 220V 50HZ | |||
| Temperature control range | RT+10℃-300℃ | |||
| Temperature resolution | ±1℃(at 100℃) | |||
| Temperature fluctuation degree | ±3% / ±2.5%(The test point is 100℃) | |||
| Temperature distribution accuracy | ±2.5% | |||
| Inner liner material | 201/304 stainless steel inner liner | |||
| Shell material | Galvanized sheet (with surface electrostatic spraying) | |||
| Insulation layer | Ceramic fibers | |||
| Heater | Stainless steel heating tube | |||
| Rated power | 1000W | 1500W | 2000W | 3000W |
| Exhaust hole (test hole) | 35mm (top) one | |||
| Control Panel | LCD/LED liquid crystal display screen | |||
| Humidity sensor | PT100 | |||
| Timer function | 0-9999min | |||
| Operating mode | Fixed-value operation, timed operation, automatic stop | |||
| Fan switch | Yes/ Built-in ten-speed adjustment function | |||
| Inner liner dimensions (mm) | 360×350×350 | 400×400×450 | 450×500×550 | 500×600×700 |
| Dimensions (mm) | 540×500×710 | 580×540×810 | 660×630×1055 | 720×730×1200 |
| Packaging dimensions (mm) | 550×600×790 | 600×640×880 | 720×700×1125 | 745×780×1250 |
| Standard/Maximum Spacer | 2/4 | 2/4 | 2/6 | 2/8 |
| Separator spacing | 60mm | 80mm | 60mm | 70mm |
| Supporting weight of the partition board | 16kg | 16kg | 16kg | 16kg |
| Gross weight | 38kg | 46kg | 65kg | 78kg |
| Additional functions | Sensor deviation correction, over-temperature alarm, PID self-tuning for temperature overshoot | |||
| Optional functions | Programmable control instrument, liquid crystal display instrument, printer, 485 interface, USB interface, SMS alarm | |||
| Picture | ![]() | ![]() | ||