Desktop XRF Mineral Analyzer (light elements) DW-EDX3600H
The high-performance desktop XRF geology and mining analyzer DW-EDX 3600H is equipped with globally advanced analysis technology, an intelligent vacuum system, and developed electronic technology. Combined with a low-energy tube, vacuum system and low background technology. It efficiently reduces testing interference and improves the energy resolution of Mg, Al, and Si. P and other light elements in geology and minerals.
Specialized in Mineral Elements and Grade Testing
- DW-EDX3600H Mining Analyzer is specially designed for the geology and mining industries.
- High precision, fast testing speed and easy operation, etc.
- Bear several testing analysis modes, including alloy, soil, precious, and RoHS.
- Testing samples include minerals, slag, rocks, etc.
- Analytical content is from Na to U.
- Testing samples can be solids, liquids, and powders.

Advantages of EDX3600H Desktop XRF
• Highly efficient super-thin window x-ray light tube, which is specially developed for mineral testing, reaches the international advanced level.
• Silicon Drift Detector (SDD), provides better energy linearity, resolution, spectrum characteristics, and a higher peak/base ratio.
• Built-in CMOS HD camera.
• Automatic switch of collimator and filter according to different samples, eliminating the troublesome manual operation.
• Triple X-ray protection design
- 1) Machanical protection: segregate x-ray
- 2) Electronical protection: Automatic shut-down of x-ray when opening the cover during testing
- 3) Software protection: Automatic shut-down of software program when opening the cover during testing
• LCD screen directly shows the important parameters: tube voltage, tube current, and vacuum degree
• 2L vacuum pump
Technical Specifications of EDX3600H Desktop XRF
| Measurable range | Na to U |
| Analytical range | ppm—99.99% (different materials, with different analytical range) |
| Simultaneous analysis | Testing tens of elements simultaneously |
| Precision | 0.05% (content 96% t) |
| Testing time | 60s-200s |
| Resolution | (140±5)eV |
| Tube voltage | 5KV-50KV |
| Tube current | 50 y A-1000 p A |
| Sample chamber size | 320mmx100mm |
| Ambient temperature | 15℃-30℃ |
| Ambient humidity | 35%-70% |
| Voltage input | AC 220V (Optional: 110V) |
| Power | 200W |
| Instrument dimension | 660mmx510mmx350mm |
| Weight | 65Kg |
Standard Configuration of EDX3600H Desktop XRF
-Highly efficient super-thin window x-ray light tube -Collimator and filter
-High-performance electronic cooling UHRD detector -Triple safety protection mode
-Signal-to-Noise Enhancer -90mmx70mm LCD
-CMOS HD camera -Vacuum Pump
Spare Parts and Testing Display of EDX3600H Desktop XRF
- Main-spare-parts
- Mine-standard-samples
- Mine-standard-samples
- Mine-software-run
- Mine-testing-result
- Mine-working-curves
Periodic Table of Elements


Application Cases of EDX3600H Desktop XRF
Case 1 — Caolin


Case 2 — Zinc concentrate


Case 3 — Lead concentrate