Benchtop Blood Bank Centrifuge DD5-XK/DD6-XK
- Advanced CPU control system, and microprocessor control, which can accurately control the speed , time and RCF, to fully meet the needs of blood bank testing. It has the advantages of low noise, little vibration, fast lifting speed and etc.
- Stainless steel Chamber and solid construction are suitable for continuously use, inflatable spring, easily open lid and automatic locking lid are security guard.
- Accurately timing: it can detect the centrifugal time to seconds, the centrifuge uses the “effective inter-centrifuge” concept, when it reaches the rated speed after starts and then countdown, it is automatically shut down when it times to “0”and can protect experimental results greatly.
- Fast up/down: Bring in”8s Acc time, 8s Dec time”, which can rate speed within 8 seconds to start or shut down.
- PWM braking function: in the process of centrifuging, the ordinary centrifuges often suffer the too long stoppage or echoes, which make settlement of the material being suspended again. While our centrifuge uses PTM pulse width and matches two damping system, which effectively ensure shutting down quickly and no echoes phenomenon.
Basic Introduction of Benchtop Blood Bank Centrifuge DD5-XK/DD6-XK
DD5-XK is a benchtop blood bank centrifuge model, which designed for blood bank special that to meet the requirement of quickly separate in blood bank test.
DD6-XK is suitable for routine sample analysis in medical, hospital, pathology and institutional laboratories. With wide variety of accessories, they can be also used for preparation of samples in industrial and research laboratories.
Features of Benchtop Blood Bank Centrifuge
- Adopt the steel structure, which is safer, simple-compact, light-weight and low-noise.
- Digital display and adopt control system realizing microprocessor control, it control rotate speed, relative centrifuge force.
- Maintenance-free frequency conversion motor, can prevent over-speed operation.



Technical Parameters of Benchtop Blood Bank Centrifuge DD5-XK/DD6-XK
| Model | DD5-XK | Max Speed | 5000r/min |
| Max RCF | 3500xg | Speed Accuracy | ±10prm |
| Motor | Brushless DC Motor | Noise | ≤60dB |
| Time | 0~99min | Power Supply | AC220V &110V 50Hz 2A |
| Weight | 20kg | Dimension | 450*340*270mm |
| Rotor | |||
| No.1 Angle Rotor | 12x10ml | 5000r/min | 3500xg |
| No.2 Angle Rotor | 12x15ml | 4000r/min | 2680xg |
| Model | DD6-XK | Motor | Brushless DC Motor |
| Max Speed | 0-6000rpm | Speed Accuracy | ±10rpm |
| Max RCF | 5040xg | Display | LCD display |
| Timer | 0~99min | Noise | ≤50dB(A) |
| Power | 125W | Voltage | 100-240V 50Hz |
| Dimension | 450×340×270mm | Weight | 20kg |
| Rotor | |||
| No.1 Angle Rotor | Max Speed:6000r/min | No.2 Angle Rotor | Max Speed:6000r/min |
| Capacity:12×10ml AR | Capacity:4×50ml AR | ||
| Max RCF:5040xg | Max RCF:5040xg | ||
| No.3 Angle Rotor | Max Speed:6000r/min | No.4 Angle Rotor | Max Speed:6000r/min |
| Capacity:12×15ml AR | Capacity:24×10ml AR | ||
| Max RCF:5040xg | Max RCF:5040xg | ||
| No.5 Angle Rotor | Max Speed:6000r/min | No.6 Angle Rotor | Max Speed:6000r/min |
| Capacity:12×20ml AR | Capacity:6/4×50ml AR | ||
| Max RCF:5040xg | Max RCF:5040xg | ||
Note: Rotors can customize made